  1. Yep seems quite common. Im dealing with one right...

    Yep seems quite common. Im dealing with one right now

    http://hvac-talk.com/vbb/showthread.php?1433821-Questions-for-the-Rheem-guys/page2&highlight=rheem+quiet+80
  2. Replies
    9
    Views
    677

    How about heat block spray and paste ? Big Blu ?...

    How about heat block spray and paste ? Big Blu ? Coil cleaner ? stuff like that
    What about electronics like vacuum gauges infrared thermometers , etc.
    Maybe Im being overly cautious but I tend to...
  3. Replies
    9
    Views
    677

    Winter storage supplies tools parts ?

    A question for veteran techs. This is my first year in the business. Love it, not bad pay at all.
    My question is: what supplies , parts, freon etc. that are normally carried in the service van can't...
  4. Replies
    16
    Views
    1,886

    What size robinair is it ? and whats a vcrt ?

    What size robinair is it ? and whats a vcrt ?
  5. Replies
    16
    Views
    1,886

    I bought a 2.75 CFM brand is Viot off ebay. Brand...

    I bought a 2.75 CFM brand is Viot off ebay. Brand new and used it today , after about one hour all I had it down to is 5500 microns. I think this one is slowwwww.
    Anyone care to share typical amount...
  6. Replies
    45
    Views
    2,633

    Its been my experience that pullers are a waste...

    Its been my experience that pullers are a waste of time. If the fanblade isnt loose after loosening the set screw I go right to the sawzall. Save yourself the hassle and cut the shaft and tap it out.
  7. Replies
    21
    Views
    1,704

    That might be possible, but as soon as I bypassed...

    That might be possible, but as soon as I bypassed the timer the compressor and fan started up and ran prefectly, so I assumed the problem was the timer.
  8. Replies
    21
    Views
    1,704

    I guess seeing as 95% of Condensing units dont...

    I guess seeing as 95% of Condensing units dont have one of these I dont see any problem with bypassing them on units that do have them.
  9. Replies
    21
    Views
    1,704

    I have seen time delays go bad and the only way...

    I have seen time delays go bad and the only way to get the system started is by bypassing it. Also majority of thermostats have built in time delay to protect the system
  10. Carrier condensing unit without schrader valve cores

    Went on a job yesterday to disconnect a condensing unit to make room to pour a patio. I went to pump the unit down and realized that both lines didnt have schrader valve cores. Started to open the...
  11. Just take the basement ceiling out of the...

    Just take the basement ceiling out of the calculation. To my knowlege you cant even consider it a partition unless the other side is an unconditioned space.
  12. If you are referring to the ~ 3,300 BTUH sensible...

    If you are referring to the ~ 3,300 BTUH sensible gain for the basement ceiling, that would be a mistake by the person that did this heat gain heat loss calc.
  13. Replies
    5
    Views
    789

    I actually never had any problem using universal...

    I actually never had any problem using universal motors. I match them to the existing motor with respect to rpm , hp etc.
    Cant see why it would be a problem. I mean thats what they were designed...
  14. I'll bet compressor shutting down periodically...

    I'll bet compressor shutting down periodically for some reason. I see installers that dont properly weigh in a charge or pull a good vacuum on new installations. I would pull out the refrigerant and...
  15. Replies
    5
    Views
    789

    Universal blower motor

    Im looking to put a few universal indoor furnace blower motors on the truck. Was considering the ao smith masterfit FDL6001 as being the one to buy. Would like to see if anybody uses these and if...
  16. Replies
    64
    Views
    9,208

    All I can say about reliability is that the GE...

    All I can say about reliability is that the GE cap in my CU in my home lasted over 14 years. It outlasted my condenser fan motor and thats the only reason I replaced it.
    One interesting note is that...
  17. Replies
    0
    Views
    306

    Best brand leak detection dye kit

    Just wondering which kit you guys would recommend ?
    Thanks,
    Bob
  18. Replies
    44
    Views
    3,307

    I was at a outdoor car show about 25 years ago...

    I was at a outdoor car show about 25 years ago and you could see and hear the bee swarm in the sky. These suckers decended on the car show and landed full swarm on a red muscle car , covering the...
  19. Yep, I asked the guy if the installers used a...

    Yep,
    I asked the guy if the installers used a scale to weigh in the charge and he said "no, they charged it to ambient plus 25". First time I heard of anybody charging a new install without a scale....
  20. Sorry I guess I meant that the subcooling was...

    Sorry I guess I meant that the subcooling was very high and the temp of the high side line was very low.
  21. Originally Head pressure - 320 psi High side...

    Originally Head pressure - 320 psi
    High side line temp - 83 degrees

    After putting in correct charge
    Head pressure -170 psi
    High side line temp - 85 degrees
  22. Just finished the service call. The head pressure...

    Just finished the service call. The head pressure was 330psi, low was about 70psi - r22
    Pulling 17 amps total. Low subcooling- very low.
    I pulled out the charge and weighed it. System requires 8...
  23. Just talked to the guy, now he tells me that the...

    Just talked to the guy, now he tells me that the system worked from 8pm last night until 1pm today and that the whole condensing unit including fan was turning on and off repeatedly and blowing warm...
  24. Heres the only info I have on this one until I...

    Heres the only info I have on this one until I check it out myself :
    All new evap coil linsets CU. Installed about 5 weeks ago and has had this problem from day one.
    He claims that the comp is...
  25. Good point . I dont have that data, yet. I guess...

    Good point . I dont have that data, yet. I guess I was just speaking in general terms as what a tech might see the system doing or not doing if there was a defective TXV.