  1. Replies
    14
    Views
    1,185

    See I have to agree

    I totally agree with Dave Tec on this one. It is apparent that you need to have the appropriate software tools to negotiate the problems with these controllers. Doing hard resets by cycling the power...
  2. Replies
    8
    Views
    1,775

    yeah

    I think it sounds like it was commissioned through Lon Spec, EVision or some other form of Honeywell Lon Control. Does the building have a front end with a LNEX on it. Probably not but worth asking?
  3. Replies
    5
    Views
    768

    Thought so

    See I had a feeling. I was wondering if you could replace the CCP's with one of the ZN controllers and still use all the comm 4 devices to talk to the BCU
  4. Replies
    14
    Views
    1,185

    Don't you have XL Online to plug into it with?

    Don't you have XL Online to plug into it with?
  5. Replies
    5
    Views
    768

    Is it possible to integrate Tracker?

    Does anyone know if it can be added to a Tridium Jace or to Tracer Summit?
  6. Replies
    55
    Views
    7,855

    Admittedly

    I have to admit this field can be really dry sometimes. Annoying too. Whether its working on the programming end or fixing problems I find myself less motivated than I used to be. At my last company...
  7. Replies
    2
    Views
    703

    Also

    If you get a Tracker with display you can generally do most of the controls through the touchpad. I found it relatively easy to configure the CCP's on the network. However the VAV's can be configured...
  8. Replies
    3
    Views
    2,123

    Hey figured I would followup

    Hey I went ahead and wiped the controller from the database and then put it back with the same configuration and everything worked fine. Somehow the software got corrupted into thinking it had the...
  9. Replies
    9
    Views
    1,505

    Have you attempted to connect through Ethernet

    Was any of your 5 connection boxes grayed out in your attempt to connect? Also did you check that your comm is off. If you find the file pcarmdrvexe in windows explorer under your tracer summit...
  10. Replies
    17
    Views
    3,683

    skeptical

    You may also want to cue him that although products maybe bacnet they may be NATIVE Bacnet and that usually means its kept proprietary.
  11. Quick question

    Now in restoring the files are you referring to the PJT or the DB or both?
  12. Replies
    2
    Views
    1,311

    yes why?

    yes why?:eek:
  13. Replies
    3
    Views
    861

    hmm

    :eek: Let me do some research and try to get back to you.
  14. Yeah I know

    I know they got CARE 7.0 out. I used to have it at an old company. Right now all I have is 2.02 and 4.02 and the 2.02 stuff is a pain to edit flipping through all those different editors.
  15. What is involved in upgrading a CARE database

    Hey I have some old 2.02 sites that I'de like to get up to 4.02 eventually and was wondering what is involved in doing this. In case anyone is wondering there are no Lon Point Servers at the front...
  16. Replies
    3
    Views
    2,123

    Yes I went through all the options on this...

    Yes I went through all the options on this controller and compared it to others on the floor. It is not set up as a standard XL 10 or OEM.
  17. Replies
    3
    Views
    2,123

    Honeywell EVision Help XL10 Smart

    Hey I am wondering if anyone has ever had this issue with EVision. On a new XL10 Smart I had an issue with the DO's used on it. 1 is for Fan and the other is for Heating Stage 1 on a FPB. I noticed...