  1. Replies
    7
    Views
    331

    I will do that Jeep Sent from my Torque using...

    I will do that Jeep

    Sent from my Torque using Tapatalk
  2. Replies
    7
    Views
    331

    Thanks dawg i updated my profile and sent you a...

    Thanks dawg i updated my profile and sent you a message also
  3. Replies
    7
    Views
    331

    LG LS090CE MINI SPLIT

    Does anyone have a troubleshooting guide or parts manual for this mini-split,the comp starts but the condensing unit fan motor never starts and the system shuts down in a few min.
  4. Replies
    3
    Views
    254

    Subcool reading was taken at the condenser ...

    Subcool reading was taken at the condenser

    Sent from my Torque using Tapatalk
  5. Replies
    3
    Views
    254

    76 degrees Sent from my Torque using Tapatalk

    76 degrees

    Sent from my Torque using Tapatalk
  6. Replies
    3
    Views
    254

    H/V CHARGING ISSUE

    New system startup 2.5 ton r-410 h/v system readings are,s/h=12,s/c=3 12 deg d/t, low side 118psi,high side 195 psi.The first floor is a walkout basement temp was 70 deg second floor 75 deg both have...
  7. Baldies got it right there I've had four leakers...

    Baldies got it right there I've had four leakers all c6 miles to the three years old

    Sent from my Torque using Tapatalk
  8. Thread: run cap question

    by splus
    Replies
    51
    Views
    2,578

    I would change it to the right one for sure what...

    I would change it to the right one for sure what will it harm the motor having the bigger one on there

    Sent from my Torque using Tapatalk
  9. Thread: run cap question

    by splus
    Replies
    51
    Views
    2,578

    run cap question

    Was on a call where there was a 7.5 cap on a motor that called for a 5mfd cap,was installed 2 years ago and running fine.Will this be okay if left like this?
  10. My company WAS installing nordyne equipment for...

    My company WAS installing nordyne equipment for 15 yearswith no issues until the microchannel systems came out.Most leakers dont show up until the second year and trying to find them have been not...
  11. Replies
    2
    Views
    150

    Thanks dawg Sent from my Torque using Tapatalk

    Thanks dawg

    Sent from my Torque using Tapatalk
  12. Replies
    2
    Views
    150

    Lennox c33 liquid line stub

    Is the 3/8od liquid line stub available as a part if so i need a part number,also the one that comes with the coil has a teflon o-ring on it do i need to install the o-ring that comes inside the coil...
  13. Replies
    2
    Views
    232

    So a standard 2.5 ring will work if OEM is larger...

    So a standard 2.5 ring will work if OEM is larger

    Sent from my Torque using Tapatalk
  14. Replies
    2
    Views
    232

    Trane blower motor question

    Trane part number moto4717 3/4 hp motor,need to know if a standard motor with 2.5 inch resilient rings will work I seem to remember some of these have 2/5/8 rings
  15. Replies
    12
    Views
    502

    The chimney has a tile liner in it now its been...

    The chimney has a tile liner in it now its been running fine for 2 days now told the customer we need to evaluate the chimney and possibly put a alum liner in it

    Sent from my Torque using Tapatalk
  16. Replies
    12
    Views
    502

    The chimney is on the outside of the house and we...

    The chimney is on the outside of the house and we have had a week off record cold here below zero wind chill

    Sent from my Torque using Tapatalk
  17. Replies
    12
    Views
    502

    Yes it will vent fine no spillage at the water...

    Yes it will vent fine no spillage at the water heater I haven't taken any draft reading yet its been venting and the boiler and then cycling for 24 hours

    Sent from my Torque using Tapatalk
  18. Replies
    12
    Views
    502

    After pulling the vent pipe off of the vent...

    After pulling the vent pipe off of the vent damper of the boiler letting it bent into the basement for a minute putting the vent pipe back on the damper in its been venting fine

    Sent from my...
  19. Replies
    12
    Views
    502

    The boiler is 125000 BTU with a 40,000 BTU...

    The boiler is 125000 BTU with a 40,000 BTU standing pilot water heater jimmy is on the outside of the house 8 inch tile lined

    Sent from my Torque using Tapatalk
  20. Replies
    12
    Views
    502

    It extends one inch into the flu I checked it a...

    It extends one inch into the flu I checked it a fee hours later and it was venting fine

    Sent from my Torque using Tapatalk
  21. Replies
    6
    Views
    511

    Triangle tube boiler with the trimax control is a...

    Triangle tube boiler with the trimax control is a nice boiler.W/M makes a fire tube boiler also which is pretty much the same heat exchanger.
  22. Replies
    12
    Views
    502

    Boiler draft issue

    Get to a no heat call on a natural draft spark ignition boiler and find the roll out under the draft hood tripped.Boiler fires and I notice its not venting at all as in the vent pipe after the vent...
  23. Thread: Wet Switches

    by splus
    Replies
    9
    Views
    571

    I have used a hair dryer but have found to just...

    I have used a hair dryer but have found to just replace it as most will trip if there is high humidity in the attic area there very sensitive after you dry them
  24. Replies
    2
    Views
    471

    LINE SET SIZE QUESTION

    Got a trane 4ttb3018 with a 4txc18 coil i serviced it a few years back and it has a 5/8suction with a 1/4 liquid line.another company looked at it as i was 5 days out and said the liqiud line size...
  25. Replies
    2
    Views
    400

    ADP TXV PART NUMBER

    adp #te36430c245b 5-ton made in 2007 its a r-22 coil with txv i need a r-410 valve i did have one from a trane 4txc coil but the threads dont match up anyone know the adp or trane part number for the...