  1. Replies
    16
    Views
    2,459

    Check your email buddy.

    Check your email buddy.
  2. Replies
    4
    Views
    369

    Yes, you are correct, it is a VAV. My SFS.S is...

    Yes, you are correct, it is a VAV.
    My SFS.S is set at NO
    My SFS.M is set at 0
  3. Replies
    4
    Views
    369

    Carrier Rtu Econ Problem

    I have a Carrier 48AKD060 and u cannot get the econ working. I have verified my parameters with tech support. The main base board was replaced due to the eeprom failing. The run status shows the...
  4. Thread: Sight glass

    by 501miller
    Replies
    33
    Views
    2,500

    I'm a big of Nylog, its like snot. It's like a...

    I'm a big of Nylog, its like snot. It's like a heavy-duty superglue which stays flexible. Leak lock will eventually crack especially ifused in close proximity to compressors (vibration).
  5. Replies
    7
    Views
    395

    Absolutely, you can use whatever air you want....

    Absolutely, you can use whatever air you want. You wouldn't want to use too high of an air pressure (20-25 psi should be sufficient).
  6. Replies
    7
    Views
    395

    It's usually the tubing, not the sensor. Most of...

    It's usually the tubing, not the sensor. Most of the time people will install a "T" and put a rubber plug over the "T" port, these tend to dry rot and crack. If your lines are good, then check the...
  7. Replies
    16
    Views
    2,459

    neilh20man, you have to update your info and...

    neilh20man, you have to update your info and include an email address in it. You will be unable to post your email in the thread. I will send the info, but please add your email into your profile.
  8. Replies
    0
    Views
    417

    Turbo Air Walk-in Condenser

    I'm trying to locate the manual for this machine and am having no luck on-line. To top it off their office is closed now. The mod# is: TS015MR404A2. I'm specifically looking for its clearances. I...
  9. Replies
    16
    Views
    2,459

    Wireman3736 check your email, I just sent it to...

    Wireman3736 check your email, I just sent it to you. Take care.
  10. Replies
    9
    Views
    881

    ZeroCool, what I mean by tested was I disabled...

    ZeroCool, what I mean by tested was I disabled the economizer until the unit got up and running (90% or better on the sf VFD) and then enabled the economizer again. It seems like the first time the...
  11. Replies
    9
    Views
    881

    Okay everything was fine until two days ago, unit...

    Okay everything was fine until two days ago, unit was down again. I bumped up the VFD speed and decreased its accel time to ensure the switch makes within the 40 sec time limit. Today the unit is...
  12. You want the box to fail to cooling: 1) Set...

    You want the box to fail to cooling:
    1) Set damper N.O.
    2) You want a N.C. valve

    This will give you fail-safe to cooling.

    Now with the R.A. stat, as you call for heat the pressure will be...
  13. Replies
    9
    Views
    881

    Thanks slctech, it does have vfd's for each fan....

    Thanks slctech, it does have vfd's for each fan. I'll look into the aux switch and apply for Pro Status.
  14. Replies
    9
    Views
    881

    Trane Intellipak EF problem

    The last couple days the unit has been having an alarm due to the EF not starting (failure). The wiring diagrams are illegible. If you kill power it will start and run fine until the next day. I...
  15. Replies
    8
    Views
    711

    Thanks catalina_mike, it was roughly a 15' run so...

    Thanks catalina_mike, it was roughly a 15' run so I reused the existing wire and the baud rate is 38.4. Thank you.
  16. Replies
    8
    Views
    711

    45 it definitely reads in the program, going to...

    45 it definitely reads in the program, going to get a RSPRO now. Baud rate set and jumper moved. Thanks for the help guys!
  17. Replies
    8
    Views
    711

    Got it thanks! Without replacing the stat,will it...

    Got it thanks! Without replacing the stat,will it still function but only the LCD won't work? Or will it read incorrectly?
  18. Replies
    8
    Views
    711

    Thanks Kontrol, one more question: What do you do...

    Thanks Kontrol, one more question: What do you do with the UNET wiring?
    The controller is already emulated.
  19. Replies
    8
    Views
    711

    Automated Logic VAV and stat

    I am replacing a U341+ controller with a ZN341+ controller. Will the LSPRO stat work? The new controller has a RNET which has a 12V terminal, but the LSPRO has a LS5V terminal. I am assuming...
  20. Replies
    16
    Views
    2,459

    picnik, thanks, you weren't kidding! Should be a...

    picnik, thanks, you weren't kidding! Should be a huge help.
    Mr. Greenjeans, thank you also for the missing piece!
  21. Replies
    16
    Views
    2,459

    That would be awesome! I'll have to do it after...

    That would be awesome! I'll have to do it after work and when I get home, the internet on my phone doesn't let me edit my own profile. Thank you!
  22. Replies
    16
    Views
    2,459

    Staefa Controls

    I've inherited a building with some older Staefa stand alone controls and can't find anything on the web to help me decipher how they operate. I mean I get the gist, MA controller, min OA, DX...
  23. Replies
    1
    Views
    269

    BTW, It's a brand new actuator.

    BTW, It's a brand new actuator.
  24. Replies
    1
    Views
    269

    Invensys TB158-017

    Just dealt with an Invensys TB158-017 stat controlling 2 3-wire floating actuators and am having a problem. When I call for cooling the chwv opens and the hwv closes. Great, right. When I call for...
  25. Sorry, reading the correct temperature

    Sorry, reading the correct temperature
Results 1 to 25 of 37
Page 1 of 2 1 2