09-06-2012, 09:04 AM
Thread: Liebert Start up question(s)
by freonguy- Replies
- 16
- Views
- 1,346
LU91tech: Yes, this is a new version compared...
LU91tech:
Yes, this is a new version compared to 2 others I commissioned less than 6 months ago - - -
Freonguy CM -
08-28-2012, 01:27 PM
Thread: Liebert Start up question(s)
by freonguy- Replies
- 16
- Views
- 1,346
Push It : Yeah, it throws a guy for a loop,...
Push It :
Yeah, it throws a guy for a loop, especially when you have worked on so many that were all the same ( in the pump down regard ).
After a long and hot installation, one system has no... -
08-27-2012, 09:20 AM
Thread: Liebert Start up question(s)
by freonguy- Replies
- 16
- Views
- 1,346
Gentle(persons): Just got off the phone with...
Gentle(persons):
Just got off the phone with Liebert - Tech Support.
Seems as though the ' pump down ' mode has been disabled for about a year or so, scrolls or Carlyle - I suppose they should... -
08-24-2012, 08:14 PM
Thread: Liebert Start up question(s)
by freonguy- Replies
- 16
- Views
- 1,346
Six: As noted, AFTER 20 minutes of running, it...
Six:
As noted, AFTER 20 minutes of running, it still dumps the compressor immediately on shutting off the control OFF / ON @ the iCOM touch pad.
I have worked on / commissioned well over 200... -
08-23-2012, 06:20 PM
Thread: Liebert Start up question(s)
by freonguy- Replies
- 16
- Views
- 1,346
Liebert Start up question(s)
Greetings:
Just a brain picking exercise - ( I have been working on Lieberts for nearly 30 years - iCOM trained , couple of AM/AG training sessions etc. )
Just comissioning a VS053WUA000266A... -
08-23-2012, 01:21 PM
Thread: Liebert Deluxe System 3 20T Glycol
by freonguy- Replies
- 17
- Views
- 1,726
[QUOTE=SuperStar79;4402902]Im guessing the...
[QUOTE=SuperStar79;4402902]Im guessing the compressor blew a gasket.
SS79:
I 'll send you 5 bucks if the compressor really blew a gasket. Just doesn't happen.
Chillerwhisperer makes a good point... -
08-22-2012, 07:53 PM
Thread: Oldest one I have ever worked on
by freonguy- Replies
- 20
- Views
- 1,933
[QUOTE=Tech Rob;14036911]Wow! Not many of them...
[QUOTE=Tech Rob;14036911]Wow! Not many of them around! I think I have seen one or two in my travels. Oldest one I take care of at the moment is a 1991 model with the Level 10 controls. I upgraded...
-
08-22-2012, 04:08 PM
Thread: Oldest one I have ever worked on
by freonguy- Replies
- 20
- Views
- 1,933
ZW17: I have a few 1989/1990 vintage units here...
ZW17:
I have a few 1989/1990 vintage units here and they all have the ' 00 ' board which is the version just after what you have - I have worked on units like the one you listed, but I am inclined... -
08-17-2012, 01:42 PM
Thread: Electric heat contactor ?
by freonguy- Replies
- 15
- Views
- 776
Heater issue
Glennhvac:
Without getting in to it, what a bout a spring wound timer ( 15 minute version ).
It could be used to energize the CC, as it is rated for 230v, and you may even find one that handles... -
07-29-2012, 02:27 PM
Thread: ISCEON® MO99™ refrigerant ( R-438a )
by freonguy- Replies
- 53
- Views
- 10,385
MO99
Thanks Toptech!!
FreonguyCM -
07-24-2012, 03:48 PM
Thread: ISCEON® MO99™ refrigerant ( R-438a )
by freonguy- Replies
- 53
- Views
- 10,385
R-438a - opinions
Thanks for the feedback so far gentlemen ( women ) - this Forum is a wealth of knowledge if we all share.
Freonguy CM -
07-23-2012, 09:25 AM
Thread: ISCEON® MO99™ refrigerant ( R-438a )
by freonguy- Replies
- 53
- Views
- 10,385
R-438a - retrofit
Boilerman:
We are located on the West Coast where it never gets really warm - yes, I was aware that the capacity drop was in the 5% range, but, in my situation, most of the equipment in the Mill... -
07-23-2012, 09:07 AM
Thread: ISCEON® MO99™ refrigerant ( R-438a )
by freonguy- Replies
- 53
- Views
- 10,385
Toptech: Do you have the Copeland bulletin of...
Toptech:
Do you have the Copeland bulletin of which you refer to? Or it's number?
We have used it in 7 systems so far at the Mill I work at, with good results. All A/C systems - Six Lieberts... -
05-29-2012, 09:07 AM
Thread: wastewater lineset failure
by freonguy- Replies
- 9
- Views
- 999
H2S ATTACKS!!
Genduct:
Yes, the copper gets attacked - but to a lesser degree.
First off, copper and brass components turn black - a thick, scaly oxide forms, especially on suction lines where there is... -
05-24-2012, 07:55 PM
Thread: wastewater lineset failure
by freonguy- Replies
- 9
- Views
- 999
Holey joints !
JSWIN:
I am at a Pulp and Paper Mill - all coils are Heresite coated, and, unfortunately all equipment comes with Silfos joints. THe H2S is the culprit to be sure - I suggest using Easy Flo 45 as... -
02-14-2012, 01:23 PM
- Replies
- 3
- Views
- 820
Refrigeration / HVAC Work
Danny:
What exactly do you do now? I have been in the trade for over 30 years in Western Canada and cannot imagine doing it without doing gas work.
Do you have a gas ticket?
PM me if you... -
12-19-2011, 04:54 PM
Thread: How old is this 2nd unit?
by freonguy- Replies
- 5
- Views
- 604
****
Sorry, my bad - will get the proper designation -
Freonguy -
09-19-2011, 08:00 PM
Thread: Ventilation for Medical Marijuana Clinic
by freonguy- Replies
- 25
- Views
- 2,093
Potsibilities
I work at a Pulp and Paper Mill - we use activated carbon ( Westvaco ) units to neutralize chemicals.
I was once talking to a somewhat unsavoury chap - when he found out I worked at a P & P Mill,... -
Leak look out
HVACkid:
What about ultra sonic? The ones sold by the HVAC wholesalers are fair at best; I am at a Pulp and Paper Mill where the instrumentation guys have a $2300.00 unit that is unbelievable -... -
07-21-2011, 09:04 AM
- Replies
- 29
- Views
- 2,331
Carlyle info
Thanks, and a good thread !!
Freonguy -
07-20-2011, 10:13 AM
- Replies
- 29
- Views
- 2,331
Vexing valve plates
Mr.Kev -
Agreed on the Bible - I have one to be sure.
Do you have a link for the rebuild manual? I have one, but it got badly water damaged and some of it is illegible.
As for the valve... -
05-29-2011, 09:20 AM
Thread: Remedy for shaft coatings?
by freonguy- Replies
- 13
- Views
- 801
Tar Trouble
Yes, WD-40 works pretty well; laquer thinner works better, however, it is more toxic.
I too use never seize on the shafts - makes doing it the next time a nicer experience.
Freonguy -
05-10-2011, 10:05 AM
Thread: Oil Pressure Safety Cutout
by freonguy- Replies
- 31
- Views
- 2,254
Oil pressure annoyance
Captain 123
Sounds like you may have it - what I was going to throw in the ring was to reverse the direction of the compressor - I have, over the years , seen a few cases where the oil pump won't... -
04-20-2011, 07:56 PM
Thread: What CFM vacuum pump
by freonguy- Replies
- 12
- Views
- 1,187
Vacuum Pump
Pascone makes a good point - I have a Ritchie # 93560 @ 6CFM - really like it.
Use a good vacuum gauge, and above all - CHANGE THE OIL REALLY OFTEN - the pump lasts, and gives good performance.
... -
03-10-2011, 09:07 AM
Thread: Fluke 79 series III DMM info
by freonguy- Replies
- 5
- Views
- 1,797
Fluke info
Tassajara:
That should be enough - - -
I will look at the differences between the II and III - but what is there will likely suffice.
Thanks for the help!!
Freonguy