Search:

Type: Posts; User: syndicated

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    30
    Views
    1,120

    Up here in Canada, goodman has just disappeared...

    Up here in Canada, goodman has just disappeared and is now called Daikin. We started installing goodman as a cheaper and more reliable option than the Lennox ML193 due to its issues with pressure...
  2. Replies
    7
    Views
    259

    The bacteria has likely started growing well...

    The bacteria has likely started growing well before the old bulb burned out. As they age, the coating on UV bulbs degrades and starts to produce more visible light.
    Adding a second bulb to shine on...
  3. It's not a power issue, but we can't tell you...

    It's not a power issue, but we can't tell you what the problem is.
  4. Replies
    17
    Views
    664

    You should seal up or remove that supply air...

    You should seal up or remove that supply air register on the plenum.
    If you need conditioned air in that space, it should be taken off further down the line.
  5. Reducing the refrigerant charge is like pulling 2...

    Reducing the refrigerant charge is like pulling 2 spark plugs out on your V8 because you're burning too much gas and want a v6.
  6. Replies
    17
    Views
    631

    Could be the underground diesel tank from the gas...

    Could be the underground diesel tank from the gas station is leaching into the ground.... Maybe it's leaching into the building.
    Happened here not too long ago
  7. Replies
    110
    Views
    3,676

    Yes. Also the kind of juice you use will affect...

    Yes.
    Also the kind of juice you use will affect its harshness.
    Higher nicotine levels are harsher, also 75-25 blends will be harsher than 50-50 blends of pg-eg.
    If you have a variable...
  8. Why is there so much corrosion on the sheet metal?

    Why is there so much corrosion on the sheet metal?
  9. Replies
    19
    Views
    1,136

    I've had that problem before on goodman units. I...

    I've had that problem before on goodman units. I think it's a material problem with the valve itself.
    It's kinda like soldering without flux...
  10. Thread: today

    by syndicated
    Replies
    10
    Views
    1,495

    That vent should be B-vent I think.....

    That vent should be B-vent I think.....
  11. We've had nothing but HX problems with all reznor...

    We've had nothing but HX problems with all reznor units. They're all junk imho. I changed a HX on a udap 2 years old, every cell had a 4" split...

    Anyways, unit heaters are our preferred method...
  12. Must be nice, we've been stuck at $.50/lb on...

    Must be nice, we've been stuck at $.50/lb on coils for years
  13. Replies
    69
    Views
    2,135

    Kenmore is not the same as carrier. I've only...

    Kenmore is not the same as carrier. I've only seen 2 of them in 10 years doing service in Calgary. I believe they're an intertherm/nordyne knockoff.
    Rheem/Ruud is good stuff, so is Lennox.......
  14. Replies
    3
    Views
    363

    You're gonna need the manual to properly...

    You're gonna need the manual to properly configure the termination. Pipe size will depend on btu of the furnace.
    The vent termination should be 12" above expected snow level. Around here minimum is...
  15. Replies
    69
    Views
    2,135

    You're completely irrational. I've installed...

    You're completely irrational.
    I've installed hundreds myself, my co. is probably well over 250,000 units installed - in southern Alberta.

    It's your money! Have fun!
  16. Replies
    69
    Views
    2,135

    We did, 4 whole years ago. Importation is banned....

    We did, 4 whole years ago. Importation is banned. Anything already in the country can still be installed, and re-installed, and repurposed...
  17. Replies
    31
    Views
    1,703

    Southern Alberta isn't as dry as people think it...

    Southern Alberta isn't as dry as people think it is. That aside, I suspect by what I've seen here that it was poor installation which caused this failure.
    I've seen many of these go 10-20 years...
  18. Replies
    26
    Views
    1,110

    Been wondering that myself. Dirty brass is around...

    Been wondering that myself. Dirty brass is around $1.40/lb around here
  19. Replies
    14
    Views
    2,021

    I found a very similar substance on some RTU's at...

    I found a very similar substance on some RTU's at a jewelry store where the owner completely shut off power to the units every night, causing very poor humidity control obviously.
    We had it tested,...
  20. Man, I love feeder tubes! It's a contractor only...

    Man, I love feeder tubes!
    It's a contractor only part, like the discombabulator and muffler rod
  21. Replies
    69
    Views
    2,135

    The B149 Canadian gas code stipulates no furnace...

    The B149 Canadian gas code stipulates no furnace vent can terminate within 36" of an openable window if the unit is over 100mbtu, 12" if under.

    The more pertinent question for me is, why are you...
  22. Replies
    69
    Views
    2,135

    Your refurb'd furnace probably isn't refurbished...

    Your refurb'd furnace probably isn't refurbished at all. It's used. The guy cleans them and sells 'em.
    There's nothing in the Canadian Gas Code prohibiting what you're proposing to do, but why spend...
  23. Got myself 2 for Xmas this year, since the wife...

    Got myself 2 for Xmas this year, since the wife doesn't have a license to buy.
    T/C venture and a Russian SKS.
  24. Replies
    4
    Views
    414

    Call tech support!

    Call tech support!
  25. Replies
    7
    Views
    587

    Is the drain plugged? Filters clogged? What's...

    Is the drain plugged? Filters clogged?

    What's the outside temperature?
  26. Replies
    80
    Views
    4,600

    Gas is a traditional apprenticeship in Alberta....

    Gas is a traditional apprenticeship in Alberta. There is no G3. 2 years for Gas B (G2), 3 years for Gas A (G1)
    Plumbers also get their Gas B when they pass 4th year of plumbing.
  27. Replies
    11
    Views
    390

    Modern refrigeration just came out with a new...

    Modern refrigeration just came out with a new edition, it's very good.
    Audel's books used to be really good, I have some printed in the 30's that are really comprehensive and detailed.
    I bought a...
  28. Yes. We need guys on the other side of the...

    Yes. We need guys on the other side of the Rockies.
    Refrigeration, sheet metal, pipe trades?
    TONS of commercial work in Calgary right now man!
  29. Replies
    12
    Views
    902

    It's non-ionizing radiation, in the microwave...

    It's non-ionizing radiation, in the microwave part of the spectrum. It's not going to hurt you long term like X-rays or UV will. The main side effect is "heating" of the exposed tissue.
    You can buy...
  30. On the Lennox, take the inducer motor out, and...

    On the Lennox, take the inducer motor out, and then the flue tee of the left hand side.
    With a 6" drill extension and some practice, that flame sensor will be shining in 15 seconds.... And you...
  31. Replies
    18
    Views
    1,085

    I think you're panicking here. I have seen many...

    I think you're panicking here.
    I have seen many old valves with corrosion on them due to being in an industrial setting. As mentioned before, aluminum corrosion is white.
    I am pretty confident...
  32. Replies
    13
    Views
    804

    I've always replace them if below 600 on an open...

    I've always replace them if below 600 on an open test. Once you load it up with a gas valve and all wiring connections you'll have too much voltage drop
  33. The Honeywell board would require an igniter...

    The Honeywell board would require an igniter change as well. Does it have provision to control the ecm blower?
  34. I am a Lennox dealer and can assure you that...

    I am a Lennox dealer and can assure you that circuit board is still very much available. The sure light board that came with the -3's has been superseded by a new part, vastly improved, as has the...
  35. Replies
    53
    Views
    3,782

    Back when I did residential, I took many after...

    Back when I did residential, I took many after hours calls from old people who were convinced that their brand new furnace (installed that day by our co.) wasn't working because they couldn't hear...
  36. Replies
    8
    Views
    335

    Never.

    Never.
  37. Replies
    14
    Views
    1,174

    Why go through all the hassle of immigrating some...

    Why go through all the hassle of immigrating some where? Go west young man, we need people out here!
  38. The saltwater will eat your condenser long before...

    The saltwater will eat your condenser long before that joint becomes an issue
  39. Replies
    72
    Views
    3,190

    100% efficient. Take that ashrae!

    100% efficient. Take that ashrae!
  40. I'm not sure of US law, but up here that would be...

    I'm not sure of US law, but up here that would be a new system and technically not be allowed. It happens all the time though, and it wouldn't cost much more for an upgrade to 410.
  41. So I'm in Calgary, and it went to -20c last...

    So I'm in Calgary, and it went to -20c last night, my indoor RH is 40% and have no condensation on my windows.
    I'm thinking you should have a window contractor come out and have a look.
    Is your...
  42. So this is a residential single phase compressor?...

    So this is a residential single phase compressor? Your ohm readings can't be right....
  43. Replies
    12
    Views
    1,135

    I stand corrected.

    I stand corrected.
  44. Replies
    12
    Views
    1,135

    Lennox has had this problem with those inducers...

    Lennox has had this problem with those inducers for years.
    It became a point for me to check on pm's as I was pulling parts to clean flame sensors on the previous G-series of Hi-eff Lennox.
    Over...
  45. It's probably a gcs3. I still have 2 I take care...

    It's probably a gcs3. I still have 2 I take care of...
    Sell them a replacement if you can. Even if you can get a relight module, the inducer is out of production. So you're screwed there as well.
  46. Replies
    19
    Views
    4,015

    He'll really be pissed when he goes to thread...

    He'll really be pissed when he goes to thread that pipe in and it's bent in the middle"

    "piping shall not be field bent"
  47. If you've got skinny-ish fingers you'll be able...

    If you've got skinny-ish fingers you'll be able to feel behind the new motor to feel if it's seated in the triangular groove.
    Use one hand to hold it in while the other turns a screw.
    You shouldn't...
  48. Replies
    27
    Views
    1,202

    I don't see how it can be tested. You'll just...

    I don't see how it can be tested. You'll just have to wait and see.

    Your Armstrong furnace is a direct copy of the Lennox ML193 furnace. I've seen many leak at the inducer coupling and collector...
  49. Replies
    2
    Views
    190

    If they installed the "healthy climate" dark grey...

    If they installed the "healthy climate" dark grey filter box for that filter, you can use different filters, however they won't fit as well in the box.
  50. Thread: kga120

    by syndicated
    Replies
    6
    Views
    363

    Lennox came out with a service bulletin early...

    Lennox came out with a service bulletin early this year concerning their micro channel RTU's.
    When they switched from fin & tube to MC coils, they didn't modify the refrigerant charge accordingly....