  1. Replies
    9
    Views
    777

    The heater will run as long as the boiler is...

    The heater will run as long as the boiler is running. It's a single unit heater in a large space. All the heaters in the building are done this way. The boiler cycle on and off on a timer. What do...
  2. Replies
    9
    Views
    777

    The boiler is in the basement and the heater...

    The boiler is in the basement and the heater would be on the 4th floor. The old heater where I'm thinking of tapping into is on the 3rd. Never been in the voiler room yet. Pig tail guage on the main...
  3. Replies
    9
    Views
    777

    There's a gate valve on 2 in vertical main supply...

    There's a gate valve on 2 in vertical main supply where it tees and goes to a unit heater then continues up to w gate valve. Can I connect to the gate valve go up one floor and too my unit heater...
  4. Replies
    9
    Views
    777

    Steam unit heaters

    Hey guys I have a customer that bought a building with a large steam boiler. I need to add a modine heater to some existing piping. I am not very familiar with steam and the proper piping techniques....
  5. Replies
    19
    Views
    2,134

    I've never seen a line set in the ground or in...

    I've never seen a line set in the ground or in the floor over the last 12 years
  6. Replies
    19
    Views
    2,134

    Refrigerant lines underground?

    I have a customer building a new store with several walkings. He wants the condensing units away from the building. There about 4o ft from the building. He wants all the pipes buried in the ground....
  7. Replies
    3
    Views
    641

    The only thing it will let me change is the temp...

    The only thing it will let me change is the temp set point. I need to change deforst max time and termination temp. It just beeps. That's is the manual I as looking at.
  8. Replies
    3
    Views
    641

    Avantco / ascend controler

    Hey guys I just replaced a controler sf104 but I'm in able to change any settings other then the temp . Any ideas? The manual I found said hold on the down arrow for 10 seconds. I get no response
  9. Replies
    1
    Views
    349

    York drain pan part number

    Was wondering If anyone out there would have a part number for a York evap drain pan. Here's the kicker it's old no model or serial anywhere. It's a 6 ton sun line with the old tandem Bristol...
  10. Thread: Pipe size

    by yotaman16
    Replies
    9
    Views
    843

    I forgot it's r22

    I forgot it's r22
  11. Thread: Pipe size

    by yotaman16
    Replies
    9
    Views
    843

    Pipe size

    Hey guys I need to move a walkin cooler condensing unit. There are two 28000 btu evaps tied together with 7/8 then run to the condensing unit with 1 1/8. The liquid line is 1/2. The condensing unit...
  12. Replies
    6
    Views
    1,231

    That was my thought also. It's a strange icing...

    That was my thought also. It's a strange icing problem. I'm heading to the site now to check the superheated now that the box is at temp and we shall know for sure
  13. Replies
    6
    Views
    1,231

    Walk in cooler icing problem

    Gita call on Thursday cooler iced up. The customer shut the condensing unit down to deice evap coil. I arrived on site to find some ice in the center of the coil along with several paper towels...
  14. Replies
    36
    Views
    4,769

    Did ou make sure the drain is trapped

    Did ou make sure the drain is trapped
  15. Thread: Gas train

    by yotaman16
    Replies
    5
    Views
    959

    Can't find any parts is my issue no one knows...

    Can't find any parts is my issue no one knows what this is
  16. Thread: Gas train

    by yotaman16
    Replies
    5
    Views
    959

    Yep they were useless. They said hey don't keep...

    Yep they were useless. They said hey don't keep info of units older then 5 years.. Great service on there part
  17. Thread: Gas train

    by yotaman16
    Replies
    5
    Views
    959

    Gas train

    Hey guys ran into a unit with a gas train in not familiar with. The first blocking valveis leaking at the solenoid. I either nerd to replace the valve or repair. I have no clue where to start and...
  18. Replies
    15
    Views
    2,757

    I dont see any sensing bulb.. To me looks like a...

    I dont see any sensing bulb.. To me looks like a fan control on a furnace
  19. Replies
    7
    Views
    2,905

    The set up thats there is so far gone it all...

    The set up thats there is so far gone it all needs to go and start from scratch
  20. Replies
    16
    Views
    3,647

    Which capacitor is that next to the flux...

    Which capacitor is that next to the flux capacitor, run capacitor or start capacitor? Im having trouble locating it !!!!!
  21. Replies
    7
    Views
    2,905

    The hood is way to small, the exhaust fan is...

    The hood is way to small, the exhaust fan is undersized and there's no make up air
  22. Replies
    7
    Views
    2,905

    Kitchen exhaust hood install

    Hey guys never done a total install on a hood. Usually just service and replace equipment as needed. I have a account that needs everything new due to the addition of new equipment. The hood has just...
  23. i went last nov. and it was great.. i did the csr...

    i went last nov. and it was great.. i did the csr class
  24. Thread: Manitowoc

    by yotaman16
    Replies
    15
    Views
    2,098

    im with ice on this.. also check the weep holes...

    im with ice on this.. also check the weep holes on the plate.. those hpr system are tricky if your not fimilar..

    Yes if you call tech support they speak english there located in Mainitowoc...
  25. Replies
    13
    Views
    1,837

    X2

    X2
  26. Replies
    13
    Views
    2,571

    Thats what i do i use the 3lb and hit a block of...

    Thats what i do i use the 3lb and hit a block of wood so i dont dent the pan then pull it out in pieces and melt the rest
  27. Replies
    68
    Views
    10,634

    Had a similar case do this to a tech at my old...

    Had a similar case do this to a tech at my old company.. Did exactly what you did and nothing..If i were you before you do anything i would do a performance curve. but i would ave the tx and nozzle...
  28. Replies
    11
    Views
    1,476

    We had had a bunch of problems with Sporland...

    We had had a bunch of problems with Sporland solenoid valves not closing.. My company wont install them any more after like the 3rd one in a year. One of those was A flare valve too
  29. Replies
    18
    Views
    2,347

    h10 is the best but...... The newer ones seem to...

    h10 is the best but...... The newer ones seem to be pickey.. I wish i had one that was 10 years old
  30. Replies
    18
    Views
    2,421

    from the looks that trane has long done its duty...

    from the looks that trane has long done its duty and that things gotta make noise in the building
  31. Thread: etc

    by yotaman16
    Replies
    8
    Views
    1,014

    I like the ETCs as was stated.. I refuse to use...

    I like the ETCs as was stated.. I refuse to use any of the multi stats.. We have had way to many problems with them, jc mr4, the sporland, dixle they dont seem to last..
  32. Thread: torch set

    by yotaman16
    Replies
    1
    Views
    919

    torch set

    hey guys im in the market for a new oxy-acy torch kit.. i currently run the smith quick braze kit but they dont make the good tip any more and was looking for a new setup.. I do all commercial...
  33. Replies
    10
    Views
    2,312

    IRON OUT .. dont say i said so tho.. will make...

    IRON OUT .. dont say i said so tho.. will make the machine look new in no time.. Im not sure as i would use try it on the nickel evap plate.. When i was out at the mani factory this year they...
  34. Thread: classes

    by yotaman16
    Replies
    5
    Views
    584

    classes

    Hey guys my company wanted me to take a gas class so i can run some calls out of state.. Should i be getting paid for this class thats 50 hrs long?
  35. Replies
    17
    Views
    10,230

    I charge both high and low depending on how much...

    I charge both high and low depending on how much gas. then let it sit but usually only 5-10 mins
  36. Replies
    21
    Views
    1,847

    i went 2 years ago it was good class and a hell...

    i went 2 years ago it was good class and a hell of a time haha
  37. Replies
    13
    Views
    2,323

    i like the way u think.. but that could make it...

    i like the way u think.. but that could make it more of a pain to change the dryer depending on the location of the glass..
  38. Replies
    17
    Views
    2,316

    what defrost clock is in the unit so we can start...

    what defrost clock is in the unit so we can start with a diagram for that becuase thats your first problem then u will be able to further troubleshoot the system
  39. Replies
    17
    Views
    2,316

    what exactly are u looking for info on?

    what exactly are u looking for info on?
  40. Thread: veto bag

    by yotaman16
    Replies
    76
    Views
    9,774

    Im probibly the cheepest person i know and it...

    Im probibly the cheepest person i know and it KILLED me to finally break down and spend 140 on the veto pro XL.. But the bag is awesome, plenty of room for all my junk, Its very sturdy and well worth...
  41. Thread: Super Seal

    by yotaman16
    Replies
    10
    Views
    1,376

    cap tube and tx valve plug in a can.. people r...

    cap tube and tx valve plug in a can.. people r just to lazy to find and fix the leak
  42. Replies
    7
    Views
    1,310

    would have to agree some of the danfoss tx in...

    would have to agree some of the danfoss tx in manitowoc machine MUST be mounted in a certain position.. But most it doesnt matter
  43. Replies
    23
    Views
    2,949

    like they said , front seat the reciever king...

    like they said , front seat the reciever king valve and see if it pumps down. If not do a performace curve or cheat if you have a suction service valve and front seat that and run the compressor into...
  44. Replies
    11
    Views
    987

    2 years sounds right, i have the same issue but...

    2 years sounds right, i have the same issue but they keep taking out the ignition every year ...
  45. Replies
    10
    Views
    1,253

    i install the ranco etc. Ive only seen one fail...

    i install the ranco etc. Ive only seen one fail and ive installed over 100 of them, but seen 2 of the 419s go bad
  46. Replies
    22
    Views
    5,078

    weird i had this happen about 2 months ago my...

    weird i had this happen about 2 months ago my self. We had a tech install a new solenoid valve sporland 3/8 sweat with extended connections and manual open stem on it. Next day evap all iced up and...
  47. Replies
    29
    Views
    3,119

    Your pumping this unit down and theres no...

    Your pumping this unit down and theres no reciever tank?
  48. Replies
    29
    Views
    2,058

    I would think that the walls of the walk in box...

    I would think that the walls of the walk in box would take a ton of moisture in seeing its gonna be 100% humidity. Unless u totally seal off everything with that said epoxy or something
  49. Replies
    10
    Views
    902

    2-3 psi is probibly taking your gages on and...

    2-3 psi is probibly taking your gages on and off.. llsv on a reach in?
  50. Thread: manitowoc

    by yotaman16
    Replies
    23
    Views
    2,024

    how would u even go about charging a critical...

    how would u even go about charging a critical charged system when theres still gas in it ??