  1. Thread: TXV literature

    by rundawg
    Replies
    1
    Views
    88

    Google - "Sporlan TXV Bulletin 10-9 and 10-11 pdf"

    Google - "Sporlan TXV Bulletin 10-9 and 10-11 pdf"
  2. Replies
    3
    Views
    143

    04 = 2004 H = August

    04 = 2004

    H = August
  3. Replies
    2
    Views
    185

    Your are correct. That code is for outdoor fan...

    Your are correct. That code is for outdoor fan motor error.

    Check your email. I sent you the manual that has the troubleshooting of the outdoor fan motor.

    If you ask for this info in the LOCKED...
  4. Replies
    5
    Views
    340

    SEER will vary with the coil installed. All...

    SEER will vary with the coil installed.

    All the Lennox Engineering Data for the newer HS29 3 ton (036) unit shows 10-11 SEER if using a TXV.

    The older Lennox HS29 3 ton units (411), using a 74...
  5. Please note that emails are not allowed in...

    Please note that emails are not allowed in threads. You already have it in your profile if someone needs it. The mods will no doubt delete it.

    We only provide technical manuals in the “LOCKED” ...
  6. Yes sorry, site rule discourage us from posting...

    Yes sorry, site rule discourage us from posting technical information or manuals in this “OPEN” forum.

    I’m not even sure that model number is correct. You might want to double check it.

    I’ve...
  7. Replies
    4
    Views
    197

    Check your email.

    Check your email.
  8. Replies
    8
    Views
    467

    A R-410A TXV in a R-22 system will have the valve...

    A R-410A TXV in a R-22 system will have the valve as far open as it is mechanically possible due to significantly more bulb pressure than there is system and spring pressure; flooding the evaporator...
  9. Replies
    3
    Views
    299

    Check your email. I sent you the parts list and...

    Check your email. I sent you the parts list and compressor performance data for this unit.
  10. Replies
    5
    Views
    318

    A R-410A TXV in a R-22 system will have the valve...

    A R-410A TXV in a R-22 system will have the valve as far open as it is mechanically possible due to significantly more bulb pressure than there is system and spring pressure; flooding the evaporator...
  11. Replies
    2
    Views
    237

    UD = upflow 95 = 95,000 btuh output. Check...

    UD = upflow

    95 = 95,000 btuh output.

    Check your email - I sent you a pdf of this unit with the model number nomenclature in it.
  12. Replies
    5
    Views
    462

    He might only have to pay part of that bet, as I...

    He might only have to pay part of that bet, as I do have manuals on this system, but there are not fault codes in them. :)
  13. Replies
    7
    Views
    342

    That model number is not correct. I'm guessing...

    That model number is not correct. I'm guessing you have a BTN930A****, and when matched with the appropriate coil, was 31,000 - 32,000 btuh.

    With that said, Ikapigian is correct - do a load...
  14. Replies
    1
    Views
    267

    It's an Air Handler. Google - Trane Low...

    It's an Air Handler.

    Google - Trane Low Pressure Climate Changer.
  15. Replies
    24
    Views
    777

    A draft gauge and combustion analyzer would be...

    A draft gauge and combustion analyzer would be your friend in this situation.

    The draft gauges would tell you if the flue has the ability to vent the combustion gases, and the analyzer would tell...
  16. Replies
    24
    Views
    777

    Because CO₂ is Carbon Dioxide, and he is worried...

    Because CO₂ is Carbon Dioxide, and he is worried about CO (Carbon Monoxide).
  17. Replies
    42
    Views
    1,393

    I've had the 5-2-1 relays opened before because I...

    I've had the 5-2-1 relays opened before because I wasn't getting good contact between terminals #1 and #2 right out of the package.

    Just pull the stickers off and they come apart.

    If I get...
  18. Replies
    42
    Views
    1,393

    Iím sure the quality of start capacitors has...

    Iím sure the quality of start capacitors has declined over the years like run capacitors have, but seeing as the start capacitor is taken out of the circuit about 1-2 seconds after the compressor...
  19. Replies
    42
    Views
    1,393

    If it has a start capacitor, it has a potential...

    If it has a start capacitor, it has a potential relay.

    The potential relay should always be changed when the start capacitor is changed, because the relay is most likely the cause of the...
  20. Replies
    6
    Views
    273

    You are correct. 018 = 1.5 tons (18,000 btuh)

    You are correct.

    018 = 1.5 tons (18,000 btuh)
  21. Replies
    7
    Views
    482

    Glad I could be of assistance. In their...

    Glad I could be of assistance.

    In their defense, Iím sure they are swamped with hundreds of calls each day, and have limited time to dig into parts manuals, or cross reference parts to other...
  22. I emailed you the Copeland Performance data on...

    I emailed you the Copeland Performance data on this compressor.
  23. Replies
    7
    Views
    482

    I think you are looking for these Grommets - part...

    I think you are looking for these Grommets - part # KA56ZZ150
  24. Replies
    27
    Views
    1,259

    R22. It is right below the serial number.

    R22. It is right below the serial number.
  25. Replies
    27
    Views
    1,259

    I agree, and for those who want to see how it is...

    I agree, and for those who want to see how it is derived:

    In the 1960's Carrier used a different serial number format.

    In the 1970’s and 1980’s they did use this 7 digit Alphanumeric format.
    ...
  26. 35 = 40,000 BTUH (3+ tons). If you had an...

    35 = 40,000 BTUH (3+ tons).

    If you had an email address in your profile, I could send you the specs on this unit.

    I don't post manuals in this "OPEN" forum.

    If you PM me with your email, I...
  27. Replies
    15
    Views
    743

    Any chance you can call first and get them to...

    Any chance you can call first and get them to give you the model number?

    That way you can take the exact one.
  28. Replies
    7
    Views
    482

    If you have the model number of the unit they are...

    If you have the model number of the unit they are installed in, I might be able to come up with something - no promises.
  29. Thread: Trane HP

    by rundawg
    Replies
    3
    Views
    248

    After digging through some other data, I did see...

    After digging through some other data, I did see where the 6H1042 systems were sometimes matched with a 3.0 ton coil - see attachment.

    So it is possible that your system was a match set at the...
  30. Thread: Trane HP

    by rundawg
    Replies
    3
    Views
    248

    I seriously doubt it is a match, but I nothing to...

    I seriously doubt it is a match, but I nothing to prove it.

    You are correct on it being a 3.5 ton heat pump, and a 3.0 ton coil.
  31. Replies
    6
    Views
    332

    I respectfully disagree. An air stream is a...

    I respectfully disagree.

    An air stream is a direction of movement, irrelevant of the starting point. The air in a HVAC only moves in one direction, whether in the supply or return.

    You take...
  32. Replies
    6
    Views
    332

    Try to think of it in context of the word -...

    Try to think of it in context of the word - stream.

    A mountain stream flows down hill. Air flows in the direction the blower motor points.

    If you are going upstream in water, you are going...
  33. Replies
    8
    Views
    553

    Airflow will be reduced when passing through a...

    Airflow will be reduced when passing through a wet coil.

    The notes at the bottom of blower chart in the units technical specs will usually state if the airflow data is based on a wet or dry coil.
  34. Thread: AHU info

    by rundawg
    Replies
    1
    Views
    251

    4 ton is correct. 40 = 50,000 btuh Check...

    4 ton is correct.

    40 = 50,000 btuh

    Check your email for a pdf on this unit.

    The unit is from 1979

    79 = 1979
  35. Replies
    5
    Views
    340

    I also emailed you the Service Facts on this unit.

    I also emailed you the Service Facts on this unit.
  36. Replies
    5
    Views
    340

    Thanks for the backup.

    Thanks for the backup.
  37. Replies
    8
    Views
    532

    Glad to help.

    Glad to help.
  38. Thread: How many tons

    by rundawg
    Replies
    1
    Views
    238

    10 = 1000 cfm X = 2 ton (RCPB-B024 coil)

    10 = 1000 cfm

    X = 2 ton (RCPB-B024 coil)
  39. Thread: Old Janitrol

    by rundawg
    Replies
    15
    Views
    669

    Could it be this guy? See attachment. If so,...

    Could it be this guy? See attachment.

    If so, there isn't much at all out there on it.
  40. Thread: Goodman ptac

    by rundawg
    Replies
    2
    Views
    287

    Check your email. I will only post manuals in the...

    Check your email. I will only post manuals in the "PRO" forums.
  41. Replies
    8
    Views
    506

    I'm am not familiar with these units, but I...

    I'm am not familiar with these units, but I emailed you a couple manuals that should help in the review the sequence of operation.

    Hopefully someone with experience in these units will pass...
  42. Replies
    8
    Views
    532

    The Goodman CLT24 (13 seer) CLJ24 (12seer) both...

    The Goodman CLT24 (13 seer) CLJ24 (12seer) both were matched with the CA*F030 coil.

    I sent you an email with their product specs.
  43. Replies
    5
    Views
    340

    The original HS29 3 ton units that had a...

    The original HS29 3 ton units that had a different model numbering, did have reciprocating compressors. Yours with the newer model numbering, always had a scroll.

    These are both 3 ton units...
  44. I don't see an email address in your profile, so...

    I don't see an email address in your profile, so send me an email (address is in my profile), and I will get off to you what I have on the Thermocouples and Powerpiles.

    I don't know if I have...
  45. Thread: Assitance:

    by rundawg
    Replies
    3
    Views
    294

    If you google "mcquay literature search", then...

    If you google "mcquay literature search", then select the result "literature search" you will get to a menu that will allow you to search the first 3 letter of the model number (RDS).

    Several...
  46. Replies
    14
    Views
    1,007

    My RE Michel and Johnston also carry them, but I...

    My RE Michel and Johnston also carry them, but I usually have to order them.
  47. Replies
    4
    Views
    295

    I don't think that cheat sheet exists. Try to...

    I don't think that cheat sheet exists.

    Try to download the Copeland Electrical Handbook which will list the capacitor size for each of their compressors.

    I know the 2008-2009 Edition can be...
  48. Replies
    4
    Views
    503

    The colors aren't exactly the same on this...

    The colors aren't exactly the same on this connection diagram of this Packard 81671 motor, but maybe it will help - see attachment.
  49. Replies
    1
    Views
    252

    Not that I am aware of. Maybe it was a local code...

    Not that I am aware of. Maybe it was a local code requirement?

    The IMC has read the same since at least the year 2000.

    307.1 Fuel-burning appliances.

    Liquid combustion by-products of...
  50. Replies
    9
    Views
    574

    Not to change the subject, but with 84 posts, why...

    Not to change the subject, but with 84 posts, why haven't you applied for PRO membership?