  1. Replies
    2
    Views
    616

    Thanks you! sorry if you have more statement or...

    Thanks you! sorry if you have more statement or example of the program related to its language code!
  2. Replies
    2
    Views
    616

    TAC IPCL documents

    Hi friend

    As now i begin to work on TAC product, any one please share me IPCL documents.


    thanks in advance
  3. Replies
    1
    Views
    726

    VSD Set up (Schneider)

    Hi Friend

    i have problem with VSD. as i connect Air Differential pressure sensor (ADPS) directly to the VSD. As the ADPS give the signal to VSD not so smoothly and make the VSD Variable too fast....
  4. Yes you are right. When you PD get higher VSD...

    Yes you are right. When you PD get higher VSD should slow down. and PD get lower VSD should speed up.

    You need to write the LOOP for this operation. For Loop statement you need to carefully set...
  5. Replies
    7
    Views
    1,239

    Hi, I dont know it yet. i just want to have...

    Hi,

    I dont know it yet. i just want to have document to see first. In design period.

    and want to have that document to study it first.

    Please share me first.
  6. Replies
    7
    Views
    1,239

    thanks for your reply my friend, cause now i...

    thanks for your reply my friend,

    cause now i just the beginning to work on Honey well.

    i use to work for Siemen before, for Example Siemen they have basic documentation to tell how to setup...
  7. Replies
    7
    Views
    1,239

    Honey well BMS system

    Hi everyone.

    Now i'm working on new project refer to Honeywell controller.

    Do you have any document refer to Basic Testing and commissioning on how to setup the controller, how to setup...
  8. Replies
    18
    Views
    2,087

    00010 ONPWRT(20)...

    00010 ONPWRT(20)
    00012 IF("AHU-SMT.CM1".AND."AHU-SMT.ADPS".EQ. OFF) THEN ON("AHU-SMT.FS1") ELSE OFF("AHU-SMT.FS1")
    00014 IF("R01.TEMP" .LE. "R01.TEMP.SETP" - 0.5) THEN SECND2=0...
  9. Replies
    18
    Views
    2,087

    For my idea, we should control it one by one: - ...

    For my idea, we should control it one by one:
    - If Temperature get the set point and Humidity not yet get the set point, you should set Valve to close and control heater but when you control...
  10. Replies
    4
    Views
    648

    Capacitor bank

    Hello

    i got some problem with design on capacitor bank
    Please provide me some technical data and schematic

    thanks so much
  11. Replies
    7
    Views
    1,551

    correct you have to check your sensor location....

    correct
    you have to check your sensor location. you find the best location yet. the best location mean to make your sensor not change the value to fast only 5 to 10Pa is ok
    you have to adjust PG...
  12. Thread: Apogee/Reno

    by nsokchea
    Replies
    38
    Views
    4,403

    Normally our insight software have user name and...

    Normally our insight software have user name and password if any one want to log in to our graphic we have many way to do that.
    - if you have additional software from siement call appogee go. This...
  13. your password the same to your last login...

    your password the same to your last login password. if you change your password in hyperterminal it will effect every time you login.
  14. actually when i disconnect 4 dimmer from the...

    actually when i disconnect 4 dimmer from the circuit (8dimmer/circuit) and left only 4 dimmers and i can adjust by using TXIO(TXM1.8). and when i put 4 dimmer back can not adjust. Normally when i...
  15. Lighting control (adjust the bright of the lamp)

    Hi all

    i have one problem

    i use sement product to control lighting by adjust the bright of the lamp(dimmer)

    But we have two kind of controller one is MEC and another one is TXIO.

    If we...
  16. Reno System with GSM modem (insight software, siemen)

    Hi

    I got one problem at one site. At that site we have many points during that point in alarm it will send sms to mobile phone and the problem is:
    - if only one point in alarm GSM modem will send...
  17. Graphic Problem when upgrade new version to insight

    Hi

    I still got the problem on insight graphic, when i upgrade verson on insight software and the graphic didn't show automatic and need to browse.

    Anyone know the solution!

    Thanks alot
  18. Replies
    3
    Views
    480

    I install already by run tecconv.exe After i...

    I install already by run tecconv.exe
    After i install how can i link to one background, i try to see help but still can not link.

    thanks
  19. Replies
    3
    Views
    480

    Siemen graphic layout

    Hi
    i got one problem regarding to the graphic, for TEC point (Fan, Valve, Temperature, Temp set point) all of these point need to insert to the graphic layout but one floor has many TEC that we...
  20. Thread: DDC panels

    by nsokchea
    Replies
    14
    Views
    6,792

    What revision of PXC you use? As my experience of...

    What revision of PXC you use? As my experience of Siemens controllers. When you turn on and off the power supply, I mean on and off only 1s or 2s it will cause the controller cool start. But some...
  21. Thread: DDC panels

    by nsokchea
    Replies
    14
    Views
    6,792

    What kind of equipments that you control? All the...

    What kind of equipments that you control? All the points in DDC are all important.
    Better look at the specification of the project. In the specification it will guard you to design the DDC panel.
  22. Replies
    9
    Views
    1,728

    Hi Thanks for your help! Actually it appear this...

    Hi
    Thanks for your help! Actually it appear this massage (The application can not be navigated to a modal dialog might be open). As your comment i can get back the graphic. But one more question if...
  23. Replies
    9
    Views
    1,728

    Hi Yes the browser look like this...

    Hi
    Yes the browser look like this (\\computername\ATOM$\... ) and it browse to the location of the graphic.
    Before i share the Database folder and then i unshare it is effect to the graphic?
    ...
  24. Replies
    9
    Views
    1,728

    Insight Graphic

    Hi

    When i open the graphic the first time it will appear the default graphic.
    But now when i open the graphic again it command me the browser to specific place. I already set the default...
  25. Replies
    3
    Views
    803

    For Apogee Go i try to set up already. But i...

    For Apogee Go i try to set up already. But i still face the problem with intranet.
    On the computer workstation itself can access to Apogee Go and see the graphic, schedule and alarm but another...
Results 1 to 25 of 31