Search:

Type: Posts; User: CantWaitToMove

Search: Search took 0.00 seconds.

  1. Replies
    1
    Views
    315

    Emailed you the TechView link

    Emailed you the TechView link
  2. Replies
    11
    Views
    1,495

    Drain's Fixed

    319801
  3. V 5.0

    V 5.0
  4. Class tomorrow. I am assuming they will review it.

    Class tomorrow. I am assuming they will review it.
  5. Trane Varitrac CCP Priority shutdown Hight Temp Input???

    I have a Varitrac approx 5+ years old that keeps randomly shutting down on me with a 3 High Temperature Input. It is approx 10 zones with one RTU. I have updated it with the current service pack. It...
  6. Replies
    3
    Views
    858

    Trane Intellipak

    Has anyone used the newer style programmable zone sensors(BAS-SVX17A-EN) on an Intellipak RTU(7 year old unit). It previously had a thermistor style non digital room sensor. We have wired the unit up...
  7. Replies
    4
    Views
    576

    Check this out. ...

    Check this out.

    http://www.viconics.com/zoning.php
  8. Replies
    0
    Views
    328

    Honeywell XL100CU

    I have 3 used ones for sale 2 2006 date codes and 1 2008 date code. I also have 1 XM100A2. We installed AX and new controllers.
    PM me if interested
    If not where is the best place to get rid of...
  9. Replies
    4
    Views
    699

    Do you still need this? I have 2 disks Service...

    Do you still need this?
    I have 2 disks Service tool 4 Version 1.0 1997
  10. Replies
    6
    Views
    754

    Any luck on this. I have 6 UHC200G3 That come up...

    Any luck on this. I have 6 UHC200G3 That come up the same. I have service integrator and I can see what all of the I/O channels are and app variables. I cannot figure out how to convert them. Any...
  11. Replies
    7
    Views
    660

    Have you watched the new webcast yet?

    Have you watched the new webcast yet?
  12. Replies
    2
    Views
    472

    At the top of the page in Lonspec. Network then...

    At the top of the page in Lonspec. Network then Refer points. Source controller point SpaceTempOut to Destination controller NviSpacetemp.
  13. Replies
    7
    Views
    758

    There always has to be a hang up.

    There always has to be a hang up.
  14. Sell them a magic wand. It should be an easy sell.

    Sell them a magic wand. It should be an easy sell.
  15. Replies
    4
    Views
    1,221

    I have a new furnace but no airflow

    :beat:
  16. Replies
    7
    Views
    758

    New to me. I am calling my distributor right now....

    New to me. I am calling my distributor right now. He is calling Tridium. I could use one right now.
  17. Replies
    33
    Views
    2,413

    Is your VVT using spyder's for your zones or...

    Is your VVT using spyder's for your zones or smarts? I am going to change our office 33cs out. I am going to try a spyder but have a 15c next to it in case. I was going to use smarts for zones. I am...
  18. Got It. Thanks

    Got It. Thanks
  19. YORK YPAL RTU ?'S STOPS WHEN BOOTING UP

    I have a York YPAL095CFB46LSAS VAV RTU that seems to have lost all of its logic. On the Optilogic Contol Center it displays

    Version A09
    Address 32
    Status No comm
    Startup OK OK OK

    Then it...
  20. Replies
    293
    Views
    10,048

    Well Said.

    Well Said.
Results 1 to 20 of 23