Search:

Type: Posts; User: alamo1718

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    484

    Check the duckbill drain. It is a duck bill...

    Check the duckbill drain. It is a duck bill shaped end on the defrost drain line that will get gummed up and not let the defrosted ice (water) out.
  2. Replies
    17
    Views
    1,201

    I had that exact ladder for a while. I used it...

    I had that exact ladder for a while. I used it about 3 or 4 times a week. Before it broke, it was great. Easy to carry, great in tight spaces. At full extension, it did bow when I got half way up...
  3. Replies
    21
    Views
    3,512

    As Snidley Whiplash or Dick Dastardly would...

    As Snidley Whiplash or Dick Dastardly would say........"Curses, Foiled again".:grin2:
  4. Replies
    142
    Views
    10,708

    Another tool I need, but didn't know I needed, a...

    Another tool I need, but didn't know I needed, a chopstick.

    Fortunately, they come two per tool bag.:grin2:
  5. Replies
    12
    Views
    1,268

    The aggravating thing is that I got .48 TSP,...

    The aggravating thing is that I got .48 TSP, which should be just under 800CFM.I believe I had the supply probe in a "slack" air pocket or I made some other mistake in static testing. I did test...
  6. Replies
    12
    Views
    1,268

    40,000 BTU, 80%

    40,000 BTU, 80%
  7. Replies
    12
    Views
    1,268

    I just went on a "blowing cold air" call. It is a...

    I just went on a "blowing cold air" call. It is a York Tg8s040ao8mp11a. I think its about 4-5 years old with a board. On the "first" call for heat, the high limit has cooled enough that the inducer...
  8. Replies
    12
    Views
    964

    Try this one. I think it will work for you. Look...

    Try this one. I think it will work for you. Look like a giant PIA. The fan assembly is attached to the evaporator, i think behind it.
    I included some pages of fan test procedures too. I have the...
  9. Replies
    12
    Views
    964

    I think this may be what you need. If not let me...

    I think this may be what you need. If not let me know, I have some other stuff too.
  10. Replies
    23
    Views
    1,732

    sloppyjoe1 I think you have to add an email...

    sloppyjoe1 I think you have to add an email address to your profile before I can private message you.
  11. Replies
    23
    Views
    1,732

    In my experience, Ge fridge delays are in the...

    In my experience, Ge fridge delays are in the board. Jumping the connector when it is disconnected from the board would by pass any delay.
    Also, take the cover off the board and rap on the relays....
  12. Replies
    23
    Views
    1,732

    I've got several service manuals for GE fridge's,...

    I've got several service manuals for GE fridge's, I don't see your model number. Is that the full model number? I have read that a bad evaporator motor or condenser motor can make a board go bad. A...
  13. Replies
    30
    Views
    2,106

    Hvacrmedic beat me to it. Car wash.

    Hvacrmedic beat me to it. Car wash.
  14. Replies
    9
    Views
    1,841

    Thank you for the responses. I was hoping...

    Thank you for the responses. I was hoping hearthman would see my post and reply. I didn't realize all the science behind soot but it makes sense. I will call and ask her about candle use Monday. I...
  15. Replies
    9
    Views
    1,841

    Soot in house from gas logs

    I was called to a customers condo today. The complaint was what appeared to be soot from the gas logs. The area directly over the fireplace is "black" dirty in the middle and it fades away mostly at...
  16. Thread: Jump?!?

    by alamo1718
    Replies
    1
    Views
    1,212

    Jump?!?

    Back on January 9th, a group of Pekin, Illinois Bikers were riding west on I-74 when they saw a girl about to jump off the Murray Baker Bridge so they stopped.

    George, their leader, a big burly...
  17. Replies
    54
    Views
    8,413

    Two questions occur as I read this thread. 1....

    Two questions occur as I read this thread.

    1. Fieldpiece SC56, my meter, has 2%+10 points on Amps.
    On capacitance it has,μF, 50μF, 500μF, 5mF Resolution: 1nF
    Accuracy: ±(3% + 15) 5μF, ±(3%...
  18. Replies
    21
    Views
    3,198

    I am currently enrolled in a Residential design...

    I am currently enrolled in a Residential design class, so my real world experience is very limited but I have the book with me.. We are using Manual Jae(Abridged Edition). It is not as many pages and...
  19. Replies
    15
    Views
    2,293

    I have a Danby Premiere in my shop.(12X24, walls...

    I have a Danby Premiere in my shop.(12X24, walls insulated, ceiling not) It's a 2 hose version, 317826 and it works great. On high the fan is a little loud but its fine on low. I use the timer to...
  20. Replies
    28
    Views
    3,156

    A way to minimize risk would be to take the...

    A way to minimize risk would be to take the condenser home after you've disconnected it. I don't know about your insurance but I'm pretty sure mine covers equipment in the truck/van.
    Also, business...
  21. Replies
    32
    Views
    4,487

    Thank you everyone, especially satuatedpsi. ...

    Thank you everyone, especially satuatedpsi.
    So, I'm going to return and remove the TXV, install a a piston, vacuum and charge to SH.:) I suspect a visiting Super installed TXV's to fix problem...
  22. Replies
    32
    Views
    4,487

    TXV bulb install question

    Several weeks ago I followed the failed maintenance supers's(several guys) attempts to fix a no cool. I found contaminated R-22 and a TXV installed with the piston still installed. The bulb was also...
  23. Replies
    8
    Views
    2,903

    Just thought i'de throw in my two cents. I am...

    Just thought i'de throw in my two cents. I am also dealing with an apartment customer with 20 plus year old filthy coils. I called the Coil Jet factory and was put in touch with a local sales rep. He...
  24. Replies
    9
    Views
    1,402

    Garyed, I have not checked blower speed yet....

    Garyed,
    I have not checked blower speed yet. That seems like a good thing to try. I thought about a plastic register also. I'll have to see if I can get one. These registers are 27 years old.
    Is...
  25. Replies
    9
    Views
    1,402

    Garyed, The condenser is a goodmanGSH130481AD....

    Garyed,
    The condenser is a goodmanGSH130481AD. My understanding of Goodman numbers gives a 4 Ton Condenser. The AH I can't tell for certain, ARUF486016BA.
    I didn't measure CFM out of the air...
  26. Replies
    9
    Views
    1,402

    Technically, it's in the wall, and I used caulk...

    Technically, it's in the wall, and I used caulk to seal it to the wall.
  27. Replies
    9
    Views
    1,402

    Sweating register

    Customer complaint was that one register is sweating during the afternoon only. I went by Tuesday morning and discovered an uninsulated duct boot. I insulated, taped and caulked, and they called back...
  28. Replies
    13
    Views
    2,162

    Thanks for the answers. One more question. The...

    Thanks for the answers. One more question.
    The condensate pan is rusted through. Do you know who it's made by? It is labeled RTD-24-CH. Serial number 1700691. It's dimensions are 2 inches deep, 9...
  29. Replies
    13
    Views
    2,162

    Is this the metering device?

    I found this today. It's on a Split Carrier indoor unit. I didn't see any other metering devices on this system.
  30. I put my amprobe on during testing. I tried three...

    I put my amprobe on during testing. I tried three times. The breaker tripped so fast I couldn't get a reading, even when I set it on "max".
    The disconnect was 1 foot from away from the service...
  31. Good call Comfortablynumb, compressor locked up....

    Good call Comfortablynumb, compressor locked up. After I repaired enough wire to to try to start the compressor, it tripped the 50A breaker. First time ran for a second then tripped.
    Still good...
  32. Could under sized cap cause a wire to blow off

    Two questions just for my curiosity.
    Here's what I found. Customer moved in Saturday, claimed it worked Sunday and Monday. No cooling on Tuesday.
    Lennox 10ACB48-10P outdoor unit, 4 ton cool only...
  33. Replies
    14
    Views
    2,226

    My interperation of Martyinlincoln was that his...

    My interperation of Martyinlincoln was that his guys that didn't have digital gauges, used the ssx34 to measure temps. That's how i use mine. For me the advantage is duplication of abilities; a cheap...
  34. Replies
    14
    Views
    2,226

    I've had one for years. Mine has been extremely...

    I've had one for years. Mine has been extremely durable. The temperature clamp can be finicky if you put it directly on a joint with solder build up or on small than 3/8.
    I use it in conjunction...
  35. Replies
    9
    Views
    1,019

    What's the best clog prevention

    Whats the best condensate clog prevention? I use various tablets and a long brush to scrub the interior of the trap when possible. My last job tonight had a clogged condense drain that they say has...
  36. Thread: New member

    by alamo1718
    Replies
    0
    Views
    800

    New member

    Hello,
    I'm new to this site. I've been reading for a couple months and figured I'd join. I am a handyman in NC. I own my own business and have been on my own for 6 years. Before that I worked in...
Results 1 to 36 of 64