  1. Replies
    3
    Views
    517

    Are there any analog ones? Which one would you...

    Are there any analog ones? Which one would you recommend?
  2. Replies
    3
    Views
    517

    Hydronic manometer

    What make/model do you guys use to calculate psi diff/gpm in chilled water/hydronic systems?
  3. Replies
    0
    Views
    232

    Chiller retrofit

    Looking to retrofit a R-22 chiller, what would be the recommended replacement?
  4. Replies
    2
    Views
    455

    No issues so far just started the units up and...

    No issues so far just started the units up and pulled the box down. Rechecking today. It's extremely noisy can't even talk on the phone near it.
  5. Replies
    2
    Views
    455

    Sporlan ser-d valves

    Has anyone experienced liquid line noise with these valves? Almost sounds like water running through the liquid line....

    Alittle background info.
    404a med temp
    Two evaps per condenser each...
  6. The unit appears to have ground going back to the...

    The unit appears to have ground going back to the panel. The uv sensor and amplifier are new (6-8months old) plus a new heat exchanger. It's a very intermittent issue I suspected a ground problem but...
  7. 7800 burner control intermittent lockout

    Has anyone seen an intermittent lockout code 15? Thoughts on what could cause this intermittent issue?
  8. Replies
    3
    Views
    426

    No, cpc e-2 controllers, i want to be able to...

    No, cpc e-2 controllers, i want to be able to connect with my laptop. Any thoughts?
  9. Replies
    3
    Views
    426

    e2b software

    Where can you download or purchase the software to connect to e2 controllers?
  10. Replies
    11
    Views
    1,134

    Yeah basically trying to find a psi washer to...

    Yeah basically trying to find a psi washer to clean larger ac units and refrigeration coils. How big of a psi washer would be needed?
  11. Replies
    11
    Views
    1,134

    Pressure washers

    What's a good psi washer to clean condenser coils? Ac and refrigeration coils?
  12. Replies
    4
    Views
    908

    Combustion analyzers

    Whats the best combustion analyzer for commercial applications?
  13. Replies
    13
    Views
    1,597

    and keeping the condenser cleaned all the time.

    and keeping the condenser cleaned all the time.
  14. Replies
    13
    Views
    1,597

    drier frosting over sounds like moisture.

    drier frosting over sounds like moisture.
  15. Replies
    11
    Views
    1,269

    does it have a txv? plugged screen possibly?

    does it have a txv? plugged screen possibly?
  16. i dont like them either. Tech support wants them...

    i dont like them either. Tech support wants them purposedly undercharged. and for the sh for eexv to be adjusted summer vs. winter. The whole setup is odd.
  17. masterbilt reverse cycle defrost system

    Anyone work on this type of system before? thoughts?
  18. Thread: fluke 922

    by spyder00087
    Replies
    0
    Views
    431

    fluke 922

    Does anyone have this meter? thoughts?
  19. Replies
    15
    Views
    1,359

    w/i freezer

    Ive got a i/c w/i freezer that always ices up the compressor but the sh is 10 at the evap. thoughts?
  20. Replies
    17
    Views
    2,512

    to check the bearings you need to loosedn the...

    to check the bearings you need to loosedn the motor on its track to allow some slack in the belts. Rolling the belts off will strain the bearings or break something. once the belts are off try to...
  21. Replies
    11
    Views
    1,113

    aggravating service call

    just took a service call for no heat, took awhile to get to the location only to find out the new rtu was never started up. the gas valve was off and the heat exchanger wasnt burned off. all of this...
  22. Replies
    17
    Views
    1,166

    Sounds low on refrigerant to me.

    Sounds low on refrigerant to me.
  23. Replies
    13
    Views
    2,313

    thanks for your insight

    thanks for your insight
  24. Replies
    13
    Views
    2,313

    its ok. i know. anyways. thanks. I did apply for...

    its ok. i know. anyways. thanks. I did apply for pro membership as well. What is the correct wall to pipe in a multiple evap system with compressor /unloading with the evaporators and compressor...
  25. Replies
    13
    Views
    2,313

    no i am not a diyer. Im a service tech.

    no i am not a diyer. Im a service tech.
  26. Replies
    13
    Views
    2,313

    more on how to pipe and layouts

    more on how to pipe and layouts
  27. Replies
    13
    Views
    2,313

    Refrigeration piping

    Does anybody know of any good refrigeration piping books?
  28. Replies
    24
    Views
    2,941

    Is there a good ground to the unit?

    Is there a good ground to the unit?
  29. Replies
    6
    Views
    614

    idont have m&s at this time. but its electric...

    idont have m&s at this time. but its electric defrost 2 independent systems. currently 45 min defrosts and defrost term at 50. Each system defrosts right after each other. Should those defrosts be...
  30. Replies
    6
    Views
    614

    w/i freezer defrosts

    What should a typical defrost schedule be for a two system freezer? and what would be a good defrost term temp?
  31. Replies
    18
    Views
    2,342

    College and trade schools are helpful. They do...

    College and trade schools are helpful. They do more than just tell you what a comp. looks like.
  32. Replies
    1
    Views
    543

    Tracker alarm

    Has anybody heard of a low resources alarm? Error code 100?
  33. Replies
    22
    Views
    4,877

    cant remember exactly the type

    cant remember exactly the type
  34. Replies
    22
    Views
    4,877

    sporlan. no, it was the second brand new valve....

    sporlan. no, it was the second brand new valve. both valves had the same problem. the valve was sized correctly. with no power to it it should close. but sometimes would stay open.
  35. Thread: txv icing

    by spyder00087
    Replies
    8
    Views
    1,602

    was this a dumb question?

    was this a dumb question?
  36. Replies
    22
    Views
    4,877

    solenoid valve problems

    found solenoid valve sticking open intermittently on a recent call. no power to coil either. any possible reasons?
  37. Replies
    10
    Views
    1,219

    liquid line solenoid valve

    recently on a call found a solenoid valve sticking open intermittently even with no power to it. any possible reasons?
  38. Thread: txv icing

    by spyder00087
    Replies
    8
    Views
    1,602

    txv icing

    is it normal for ice buildup on txvs and distrib. tubes in a freezer application?
  39. Replies
    21
    Views
    3,522

    ori/ord??

    ori/ord??
  40. Replies
    18
    Views
    1,396

    its in direct contact in the liquid line. yea not...

    its in direct contact in the liquid line. yea not much info on it, i cant seem to find much info. The condensing unit doesnt have much in the way of head psi control other than a thermostat cycling...
  41. Replies
    18
    Views
    1,396

    sorry no pics

    sorry no pics
  42. Replies
    18
    Views
    1,396

    Yes i think so. Its the first time i ever seen...

    Yes i think so. Its the first time i ever seen one before.
  43. Replies
    18
    Views
    1,396

    well its a pump in line. on the liquid line after...

    well its a pump in line. on the liquid line after the reciever. Basically similar to a b&g series 100. I believe its powered all the time when the compressor is on.
  44. Replies
    18
    Views
    1,396

    Yea stupid question right? I saw it on a older...

    Yea stupid question right? I saw it on a older bohn condensing unit. W/i Freezer application. R-22.
  45. Replies
    18
    Views
    1,396

    Liquid amplifier

    What is the purpose of it?
  46. Replies
    18
    Views
    2,027

    no it kinda looks like a honeycomb. But is made...

    no it kinda looks like a honeycomb. But is made out of aluminum, no copper. The one i saw was on a heatcraft and failed in two days of startup. A crack was on the ubend on the inlet.
  47. Replies
    18
    Views
    2,027

    Hyper core: microchannel

    Has anybody encountered this coil yet? Thoughts?
  48. Replies
    6
    Views
    952

    No problems. Just wondering. I was told that 414b...

    No problems. Just wondering. I was told that 414b was a better choice if the cap tube was starting to restrict. Is that true?
  49. Replies
    6
    Views
    952

    414b vs. 134a in cap tube systems

    which one is better?