    The site will have AX next year, so I need to get...

    The site will have AX next year, so I need to get this 1 unit back on line.
    If I could see the variables to bind I'd be done.
  2. Replies
    3
    Views
    354

    Lon Maker and CVAHU Issue

    I have a site that is Circon with Lon Maker 3.13.20.
    They are not going to upgrade the site at this time.
    I am replacing the RTU controller with a W7550C.
    I brought the controller into the Lon...
  3. Replies
    0
    Views
    411

    York OptiPlex Lon Card Program and XIF

    I am in the process of restoring the front end of an existing building.
    I have two York 50 Ton Units with OptiPlex controls and a Lon Card. The Lon card is not very good but it is what I have to...
  4. Replies
    0
    Views
    861

    Titus zeon series Zapper

    This item has been obsolete for probably 6 years. Titus and associated reps cannot find any. Does anyone have any hidden somewhere or know anywhere I could find some?
    Z-Zapper Infrared wireless...
  5. Replies
    12
    Views
    1,691

    Tried That. I'm Trying To Get Them To Get A...

    Tried That.
    I'm Trying To Get Them To Get A Phone Line Even If Temporary.
    I Do Notice I Have No Communication Lights Plugged Into Com1 And Pcl.
    Hyperterminal It's Perfect
  6. Replies
    12
    Views
    1,691

    PCLedit more issues

    I have a system that just lost the database and the facility now has a policy no phone lines. Created a problem for restore.
    Went to site with backup and PCLedit and the correct trane cable...
  7. Replies
    6
    Views
    846

    Make sure The directory...

    Make sure The directory C:\LonWorks\types\User\Echelon\ is in the Device resource files editor.
    I agree with reloading from disk though.
  8. Replies
    6
    Views
    1,466

    Are the network variables supplied with the UKLON...

    Are the network variables supplied with the UKLON enough for your application?
    If so Any lonworks controller can control the Lon points of the UKLON.
    I did a job where I used Honeywell XL50's and...
  9. Replies
    43
    Views
    12,010

    I have had many failures with this actuator motor...

    I have had many failures with this actuator motor made in china. I also had a friend with set point he had a building and he had to change all of them out (per customer). My Belimo rep through my...
  10. Replies
    8
    Views
    761

    The problem is definitely in the VariTrac PC...

    The problem is definitely in the VariTrac PC Software.
    Set up remote connection:
    COM port: 2 Name of building, phone number
    Click on the name of the building under remote connect get:
    "Unable to...
  11. Replies
    8
    Views
    761

    I'm connecting directly to the VariTrac12 no...

    I'm connecting directly to the VariTrac12 no tracker.
    My modem connects fine with everything
    I connect fine at the panel.
    I'm using the Trane software for this unit not Hyperterminal.

    When I...
  12. Replies
    8
    Views
    761

    I connect locally fine. I'm using the Tarane...

    I connect locally fine. I'm using the Tarane VariTrac Software. I guess I could use hyper terminal I thoght I would try the trane software. I configured the system with it. The device does not have...
  13. Replies
    8
    Views
    761

    VaiTrac V12 Software

    When trying to connect remotely using a modem I get the error "Unable to perform upload Comm port unavailable or busy". I verified the port is free. It is on Com 2. Then the software says to "wait...
  14. Replies
    12
    Views
    2,077

    I would like to obtain the software to download...

    I would like to obtain the software to download the P2 file if possible since there is quite a bit to enter. Also I dont have a print out of the points set up. I'm not familiar with CDM software and...
  15. Replies
    12
    Views
    2,077

    Federated Database Utility 6.1.8

    Noticed this Powers Landis/Gyr system has a backup file with a P2 extension The Job Log Text file says it's Objectivity Federated Database Utility Version 6.1.8. I'm getting ready to re type in the...
  16. Replies
    12
    Views
    2,077

    Thank you for the help, thats what I needed.

    Thank you for the help, thats what I needed.
  17. Replies
    12
    Views
    2,077

    Landis Gyr Load Program

    I need to reload a program, about 10 years ago I had taken care of another 600 system. I seem to have forgot or I have some settings wrong. I do not get the option for dataransfer only the cassette....