  1. Thread: "A" vs "B" nozzles

    by kdt
    Replies
    13
    Views
    1,202

    Thanks Doc. Beckett recommends a HAGO .65 60...

    Thanks Doc. Beckett recommends a HAGO .65 60 B nozzle for my burner/boiler combination. Your chart sparked me to do some more research and I found the HAGO site that outlines their nozzles....
  2. Thread: "A" vs "B" nozzles

    by kdt
    Replies
    13
    Views
    1,202

    Thanks for the responses. My oil company was...

    Thanks for the responses. My oil company was responsive and sent out another tech to change the nozzle. I wish I could say that I was pleased by the experience, but unfortunately it turned out...
  3. Thread: "A" vs "B" nozzles

    by kdt
    Replies
    13
    Views
    1,202

    I think it was what was available on the truck,...

    I think it was what was available on the truck, as there were no performance issues with the burner. I noticed the red cap after he installed it (the prior nozzle had a blue cap), so I looked at the...
  4. Thread: "A" vs "B" nozzles

    by kdt
    Replies
    13
    Views
    1,202

    "A" vs "B" nozzles

    I have a Buderus G115-28 boiler with a Beckett AFG oil burner. It has always worked fine. The specs say to use a .65 X 60 degree B nozzle. The oil company tech was here today for the yearly...
  5. Thread: Mixing valve

    by kdt
    Replies
    6
    Views
    1,426

    I'm having an issue with a newly installed mixing...

    I'm having an issue with a newly installed mixing valve. I'm not sure they put piped it for a "heat trap". So I can be a little more informed when I call my installer, could someone define what a...
  6. Replies
    16
    Views
    6,744

    Dave, I'm from PA. Beenthere and Oil LPMan: ...

    Dave, I'm from PA.

    Beenthere and Oil LPMan: Thanks for the tips. The Honeywell AM-1 Series mixing valve is right above the tank (a little off to one side). I have well water with a water...
  7. Replies
    16
    Views
    6,744

    Update: They installed a Honeywell tempering...

    Update: They installed a Honeywell tempering valve off my Buderus hot water tank, as well as the separate circulator to supply the tank. The valve seems to work OK, but there is a complication. When...
  8. Replies
    19
    Views
    5,328

    Dave, They installed the tempering valve off...

    Dave,

    They installed the tempering valve off my Buderus hot water tank, as well as the separate circulator. The valve seems to work OK, but there is a complication. When set at 120 degrees (the...
  9. Replies
    16
    Views
    6,744

    r&mcc He will be installing a separate...

    r&mcc

    He will be installing a separate circulator and a tempering valve next week, at no extra charge. I am pleased that he is willing to make it right. He provided a lot of little "extras" at...
  10. Replies
    19
    Views
    5,328

    Dave, On the second picture down, is that a...

    Dave,

    On the second picture down, is that a flow check valve on the boiler water supply to the tank? My install did not have any flow checks installed, so I was wondering if one is needed both on...
  11. Replies
    16
    Views
    6,744

    Thanks for the feedback and tips. It appears...

    Thanks for the feedback and tips. It appears pretty certain that the zone valve is malfunctioning, letting hot boiler water into the tank when it is not called for.

    Dave, I like the idea of a...
  12. Replies
    16
    Views
    6,744

    I recently had a Buderus G115 boiler installed,...

    I recently had a Buderus G115 boiler installed, with a Buderus ST-150 40 gallon indirect hot water tank. The aquastat for the hot water tank is a Goldline SP-30D, one of the controls recommended by...
Results 1 to 12 of 12