  1. If you're connecting to it with Ethernet you need...

    If you're connecting to it with Ethernet you need to pull the DNA jumper off, reset and then you can software address the device. RTFM
  2. Replies
    4
    Views
    359

    Line 2 is rotating the program to line 3 after a...

    Line 2 is rotating the program to line 3 after a 10 second delay.
    You need to contract the services of a professional programmer.
    This site is not for amateurs or DIY's. You could cause serious...
  3. Replies
    13
    Views
    746

    You'd be surprised at how many people in this...

    You'd be surprised at how many people in this business can't figure out the square root of 1 without a calculator.
    And it's very difficult to find someone who knows what "root of the mean squared"...
  4. This is not DIY site. you should hire a...

    This is not DIY site. you should hire a professional!
  5. Replies
    20
    Views
    1,174

    By the way... That controller was great back in...

    By the way... That controller was great back in the 1980s. But this is a whole new century already. Time to upgrade..
    Just my $0.02
  6. Replies
    20
    Views
    1,174

    There should be a small paper tag on the control...

    There should be a small paper tag on the control board with &neXXX number and the password typed below it.
    There is also a switch on the board to select the connection between c-port and s-port or...
  7. Replies
    20
    Views
    1,174

    When Was the last time you changed the Batteries?...

    When Was the last time you changed the Batteries? There should be 2 each 12 volt 7AH batteries in the enclosure wired in series connected to the power supply.
  8. Replies
    20
    Views
    1,174

    Your first problem is the number of IOUs. If I...

    Your first problem is the number of IOUs. If I remember correctly a AC256M plus could support 2 IOUs and 32 LCUs. But that was along time ago. There maybe a few Andover guys who might remember...
  9. Like I said "Real Control guys aren't made.......

    Like I said "Real Control guys aren't made.... Their born that way" this thread is really starting to show the personality traits the wanabes would like to have.



    I was in a meeting once with...
  10. I like the idea Matrix. Put a teaser in the...

    I like the idea Matrix. Put a teaser in the mouse and give the LUser a zap of varying degrees of High Voltage based on the problem he's about cause.

    And prompt him with the question

    "yes...
  11. Natural born A$$holes Control techs aren't made....

    Natural born A$$holes
    Control techs aren't made. Their born that way.
    They suck it up and do the job ease. The wanabes struggle all the way.
  12. Replies
    11
    Views
    480

    Actually I think using and Event to monitor a...

    Actually I think using and Event to monitor a device is a good idea. Set up and Event Log (EVL) and it will record each online and offline event. as well as send an alarm to the end LUser.
  13. Thread: Delta GCL+

    by AutoPilot
    Replies
    12
    Views
    419

    Onfor and Offfor Statements set internal timers...

    Onfor and Offfor Statements set internal timers in the program. The trace dots are just indicating that those lines with specified conditions are setting/resetting the timers.
  14. Replies
    2
    Views
    315

    I use a Fluke Model 1587 multimeter. The best...

    I use a Fluke Model 1587 multimeter. The best meter I've ever had.
  15. Replies
    11
    Views
    480

    Yea that makes sense. I would still use an EV...

    Yea that makes sense.
    I would still use an EV pointed at the Device to alarm if the device is really offline.
    If you use an AI the AI could go into fault, but the device may still be online.
    If...
  16. Replies
    11
    Views
    480

    Weird. Try this workaround. Create an EV...

    Weird. Try this workaround.
    Create an EV (event) Object that's "Change Of State" and make it monitor the Dev Object from the device in question.

    No need to set the alarm state.
    Program a line...
  17. Replies
    11
    Views
    480

    What kind of Device and Manufacture?

    What kind of Device and Manufacture?
  18. Replies
    11
    Views
    480

    Does the device show up in ORCAview navigator?...

    Does the device show up in ORCAview navigator?
    Use Dev in filter bar in the right hand side of navigator and check the value.
    If the device is online it should indicate "operational".

    In the...
  19. Replies
    11
    Views
    480

    I would use something like "if (9122.dev9122 ...

    I would use something like "if (9122.dev9122 <> operational) then".
  20. Replies
    4
    Views
    757

    Andover Continuum is probably the most powerful...

    Andover Continuum is probably the most powerful building automation software there is. I have been working with Andover stuff for almost 20 years. I've never run into anything I could not do with...
  21. Thread: Delta GCL+

    by AutoPilot
    Replies
    12
    Views
    419

    I think the trace dot is related to the "OnFor"...

    I think the trace dot is related to the "OnFor" timers. To make the code easier to read and understand you should use only one "Onfor" or "Offfor" on a single line only. Create local variables for...
  22. Replies
    4
    Views
    401

    If there are no Access Control panels or...

    If there are no Access Control panels or personnel records in the system, the owner of site should have no problem giving you a temporary logon. Even if there were access records on the system he...
  23. Replies
    15
    Views
    1,691

    Have you tired to contact the contractor who...

    Have you tired to contact the contractor who installed your Delta system for support?
  24. You need to check the Modbus side at the VFDs. ...

    You need to check the Modbus side at the VFDs. Check out getting a Modbus RTU Simulator.
    If both Drives have the same Modbus address you won't get any data.
  25. Replies
    7
    Views
    905

    Thanks Joey My older G.E. Turbo-Encabulator has...

    Thanks Joey
    My older G.E. Turbo-Encabulator has been given me trouble lately... Wont restart automatically after a power outage, and G.E. doesn't make spare parts for it anymore.
    Some of the idiots...