  1. Replies
    29
    Views
    1,942

    Looks good. Partner's I+O manual calls for 1"...

    Looks good. Partner's I+O manual calls for 1" piping and IF a zone valve is to be used, a CAREFULLY selected one with proper Cv, etc. I would forget the zone valve engineering and put in a three...
  2. Replies
    29
    Views
    1,942

    Not liking the zone valve operated indirect zone....

    Not liking the zone valve operated indirect zone. Precious time is lost waiting for the valve to open and energize the boiler on recovery call.

    Piping should be 1" from boiler to indirect. A...
  3. Replies
    29
    Views
    1,942

    What a waste of fuel, with the boiler set up to...

    What a waste of fuel, with the boiler set up to maintain temp like it had a coil inside. Your oil company is loving it though.

    Does the indirect have a dedicated circulator? Is it prioritized?
    ...
  4. Replies
    1
    Views
    576

    IF you have an indirect, IF the boiler and the...

    IF you have an indirect, IF the boiler and the indirect are sized properly and IF things are wired properly, the boiler should not be running off a low limit at all. When the indirect calls, it...
  5. Replies
    5
    Views
    1,759

    Is this piped primary/secondary, and EXACTLY like...

    Is this piped primary/secondary, and EXACTLY like the I+O manual?
  6. Long post. Here's my thoughts..point 1: If you...

    Long post. Here's my thoughts..point 1: If you are looking at a three pass boiler, you are not looking at an expensive-to-run boiler with a hot water coil. I haven't installed a coil boiler in 10...
  7. I'm taking it that the air scoop is on the...

    I'm taking it that the air scoop is on the return. Because I HOPE the rad zone is the first set of T's off the primary loop. They using an internal pump for the primary loop?

    The Laars cousin, the...
  8. You will need an oil burner tech's keen and...

    You will need an oil burner tech's keen and practiced eye to sort this out for you..
  9. Hmm. Gravity systems were out by '55. So it's...

    Hmm. Gravity systems were out by '55. So it's possible it is a converted steam job.

    No matter. Your plan to do home runs w/ manifolds, Fosta, is a great one. Put thermostatic radiator valves on...
  10. Thread: Boilers

    by hydronicsman
    Replies
    19
    Views
    888

    What kind of domestic load are we talking?

    What kind of domestic load are we talking?
  11. Replies
    9
    Views
    1,485

    I'm not familiar with Knights reset curve...

    I'm not familiar with Knights reset curve adjustments, but if you can shift it to accomodate the CI rad emmitters that would be good. Resets work linearly, as far as I know there is no bang on below...
  12. And the oil industry eats it's young. Again....

    And the oil industry eats it's young. Again. Unbelievable.
  13. Replies
    7
    Views
    2,027

    You can run some Rohmar 9100 through it. Is it a...

    You can run some Rohmar 9100 through it. Is it a 100% water system or glycol'd?

    Keep in mind that the black boiler water is the good stuff. Dead, de-oxygenated gold.
  14. Your first mistake was to not replace the whole...

    Your first mistake was to not replace the whole thing. Fooling around with the burner nozzle and pump pressures isn't going to change anything. It SEEMS like it is, but the readings are happenstance....
  15. Replies
    46
    Views
    2,347

    "good hack work" LOL!

    "good hack work" LOL!
  16. Replies
    46
    Views
    2,347

    That's some funny stuff! If it's the supply...

    That's some funny stuff!

    If it's the supply plenum, bad. If it's the return plenum, only if they had no choice.
  17. Replies
    110
    Views
    7,553

    Musta been a humdinger for 5 pages to be...

    Musta been a humdinger for 5 pages to be vaporized :)
  18. Replies
    110
    Views
    7,553

    I'm pretty much spitting fire at the cavelier,...

    I'm pretty much spitting fire at the cavelier, general, and presumptuous
    internet statement about the BTU's per sq ft guess. 50-60 BTU's per sq ft???

    I just had a HO last week quote me the SAME...
  19. Replies
    14
    Views
    771

    The only homes that I would give a pass to with...

    The only homes that I would give a pass to with returns in the baths would be Andie McDowall's and Julianne Moore's. There is no possible way those women can emit any foul odors.
  20. Replies
    286
    Views
    14,784

    Count on more joints (read potential leak points)...

    Count on more joints (read potential leak points) with stick copper. I only use it for aesthetics on that rare job where the lineset has to run outside exposed horizontal for many many feet.
  21. Replies
    286
    Views
    14,784

    Been using my Yellow Jacket bender 10 years now....

    Been using my Yellow Jacket bender 10 years now. LOVE it. A lot of times am able to have just two connections, just like the liquid line :)
  22. Replies
    19
    Views
    2,197

    Do some more research on DV three pass boilers....

    Do some more research on DV three pass boilers. Then you can get at least Energy Star 86% +/- units. I know Buderus G115 (WS) can be had in DV, not sure if Burnham's MPO can be DV. I've done the...
  23. I have been seeing the utilities use pex type gas...

    I have been seeing the utilities use pex type gas piping for burial in the street/branch runs.

    I've even done burial with plastic for grills and generator installation.
  24. Replies
    16
    Views
    6,061

    You realize that electronics make the spark and...

    You realize that electronics make the spark and the gas valve work on modern atomospheric boilers?

    I may pick up a nail at any time driving, but it doesn't stop me from purchasing pneumatic tires.
  25. Apparently the inspectors are looking for...

    Apparently the inspectors are looking for positive grounding, and buried pipe won't cut it. Plus, they don't know if newer composite material was used, interrupting path.

    If there is a dedicated...