Search:
Type: Posts; User: jackal
Search: Search took 0.03 seconds.
-
02-11-2013, 08:44 AM
Thread: Traulsen, TXV's but no receiver
by jackal- Replies
- 21
- Views
- 699
I think some "receiver" capacity is in the design...
I think some "receiver" capacity is in the design of the condenser. Or the condenser can hold the entire refrigerant charge. If memory serves I've serviced a few freezers with TXV's and no receiver...
-
01-03-2013, 01:43 PM
Thread: r12 refrigerator pressures
by jackal- Replies
- 8
- Views
- 768
I did appliance repair a long, long time ago and...
I did appliance repair a long, long time ago and if memory serves you could be looking at an oil cooler. Seems the compressor oil cooling was a small circuit routed through the static condenser, but...
-
08-27-2012, 02:42 PM
Thread: Convert R-12 keg cooler to R-134a.
by jackal- Replies
- 9
- Views
- 575
You may encounter high head pressure issues as...
You may encounter high head pressure issues as R-134A needs a little more condenser surface area than R-12. If it ran with low condensing pressures with R-12 it may work OK.
-
11-14-2011, 08:48 AM
Thread: Bob Vila & EdenPURE portable heater
by jackal- Replies
- 48
- Views
- 13,513
I think I will start marketing a heat pump sleeve...
I think I will start marketing a heat pump sleeve window unit with a big Amish built wood frame. At least I could advertise the energy savings and sleep a night!
-
11-03-2011, 08:49 AM
Thread: Deli Cases, Regular Headaches...
by jackal- Replies
- 15
- Views
- 1,516
You stated that your super heat was low or non...
You stated that your super heat was low or non existent, that being the case you better get that up or you'll slug and destroy the compressor. I had similar problems on a case like yours so I...
-
09-08-2011, 07:36 PM
Thread: Bohn coil leak
by jackal- Replies
- 8
- Views
- 840
Yes, I had success fixing it. I used a small...
Yes, I had success fixing it. I used a small air-acetylene tip and #15 braze. I was just nervous because once I got a copper bend too hot with my oxy-acetylene and it melted the pipe. I was amazed...
-
09-08-2011, 01:36 PM
Thread: Bohn coil leak
by jackal- Replies
- 8
- Views
- 840
Bohn coil leak
Got a 13KBTU bohn refrigeration coil with a leak on a copper loop near the TXV. Coil looks to be in reasonably good condition. I am thinking about trying to repair it, but am a little nervous with...
-
08-23-2011, 07:31 PM
Thread: Substitute liquid for suction driers...
by jackal- Replies
- 23
- Views
- 1,752
All good points--thanks.
All good points--thanks.
-
08-23-2011, 09:01 AM
Thread: Substitute liquid for suction driers...
by jackal- Replies
- 23
- Views
- 1,752
Substitute liquid for suction driers...
Can I substitute a liquid line filter drier for a suction line drier or is there some critical difference. I have a bunch of leftover large liquid line driers and i thought I could use them up as...
-
06-17-2011, 08:43 AM
Thread: I love the bar
by jackal- Replies
- 2
- Views
- 580
I've actually taken the air cooled condenser and...
I've actually taken the air cooled condenser and remoted it to a more desireable space which worked well. If you chose to do this you'd have to put a fan on the compressor to keep it cool.
-
05-25-2011, 01:47 PM
Thread: Installed last winter...
by jackal- Replies
- 11
- Views
- 2,087
I think that's actually a flexible refrigerant...
I think that's actually a flexible refrigerant pipe. Kinda remember seeing one like that out in the field quite a few years ago. You'd never even be able to get a positive pressure on a real piece of...
-
05-06-2011, 03:58 PM
Thread: converting from 134a to 404a
by jackal- Replies
- 10
- Views
- 1,637
Well you'll certainly need a new cap tube. Why on...
Well you'll certainly need a new cap tube. Why on earth would they change it from the original 134A to 404A. Better double-check with tech support people.
-
04-15-2011, 01:36 PM
Thread: Portable Water Flow Meter, 23 21 13, 2.6
by jackal- Replies
- 2
- Views
- 412
Hugh?
Hugh?
-
04-15-2011, 08:58 AM
Thread: Tecumseh high vs. medium torque compressor
by jackal- Replies
- 6
- Views
- 712
Works fine. You'll like the extra starting torque.
Works fine. You'll like the extra starting torque.
-
04-08-2011, 01:37 PM
Thread: Monumental CO2 Misinformation
by jackal- Replies
- 31
- Views
- 2,332
I may be wrong, but I'm guessing the CO2 would be...
I may be wrong, but I'm guessing the CO2 would be made from the CO2 already in existence in our air and not CO2 as a result of chemical reaction like the combustion process of an automobile so there...
-
03-23-2011, 07:25 AM
Thread: Charging self-contained units by weight?
by jackal- Replies
- 27
- Views
- 2,522
I always use dial-A-Charge for those critically...
I always use dial-A-Charge for those critically charged units. Seems to work really well for accuracy.
I hear reference to subcooling for charge on small units, but what kind of subcooling numbers... -
03-21-2011, 12:44 PM
Thread: Walk in cooler coil acid
by jackal- Replies
- 23
- Views
- 1,880
One of the big problems is the thin copper they...
One of the big problems is the thin copper they are using in modern coils. I have seen old evaporators in terrible environments 20 and 30 years old with no leaks. They have really thick copper and if...
-
11-01-2010, 01:07 PM
Thread: Apolitical Blues
by jackal- Replies
- 13
- Views
- 752
I regret that this is not really democracy or...
I regret that this is not really democracy or representative democracy anymore (whatever you like to call it) what we have is a system of legalized bribery. Corporations can now give unlimited funds...
-
09-08-2010, 01:28 PM
Thread: Heat Reclaim
by jackal- Replies
- 9
- Views
- 638
Heat reclaim is used to give people comfort so...
Heat reclaim is used to give people comfort so run it off a normal thermostat and kick it in when the space needs heat.
Water valve? I assume you mean to control condenser head pressure? You can set... -
07-30-2010, 08:57 AM
Thread: 401b/MP66 not that popular around here
by jackal- Replies
- 6
- Views
- 435
I just reread your post and realized you were...
I just reread your post and realized you were wondering why contractors don't use 401B, well that's probably due to price and as others have stated and there aren't that many R-12 low temperature...
-
07-30-2010, 08:52 AM
Thread: 401b/MP66 not that popular around here
by jackal- Replies
- 6
- Views
- 435
R401B has much better capacity at those lower...
R401B has much better capacity at those lower evaporator temperatures and allows for healthier compressor operation. Low temperaure compressors really hate high superheat (which can occur from a...
-
07-16-2010, 03:46 PM
Thread: Rotary compressors
by jackal- Replies
- 4
- Views
- 598
I've seen some cases where rotary compressors are...
I've seen some cases where rotary compressors are factory equipped with a potential relay and start capacitor. They have more umph on start up, but I don't know if they could be installed with a...
-
05-27-2010, 09:22 AM
Thread: air cooled to water cooled
by jackal- Replies
- 4
- Views
- 452
air cooled to water cooled
I have converted air cooled refrigeration equipment to water cooled with no problems, but I am wondering if I could run a water cooled condenser off the compressor in series with an air cooled...
-
10-06-2009, 01:45 PM
- Replies
- 29
- Views
- 3,290
The evaporator on that unit is designed to run at...
The evaporator on that unit is designed to run at around zero degrees F., since you are running it continually at a higher temperature the compressor is working very hard and will likely fail.
... -
08-06-2009, 09:40 PM
Thread: GE refrigerator question
by jackal- Replies
- 2
- Views
- 457
GE refrigerator question
Hi all.
(I posted this in refrigeration and ice making as well)
I got a call from a friend who wanted some phone technical support from me to troubleshoot his GE PDS22MISABB refrigerator.
I...
Results 1 to 25 of 217