Search:
Type: Posts; User: ambarton
Search: Search took 0.01 seconds.
-
02-15-2012, 06:33 PM
- Replies
- 86
- Views
- 3,393
I think that's a heat pump so it should have one...
I think that's a heat pump so it should have one already. You can't pipe accumulators in series.
-
02-13-2012, 08:25 PM
Thread: can I use R-134A instead of R-12
by ambarton- Replies
- 4
- Views
- 1,143
if your buying that stuff at the auto part stores...
if your buying that stuff at the auto part stores they do offer the drop in for r12 systems in the little jugs. youll just need some adaptors to get you from 1/2 inch acme to 1/4 flare so you can use...
-
02-13-2012, 08:04 PM
Thread: can I use R-134A instead of R-12
by ambarton- Replies
- 4
- Views
- 1,143
I think they make a drop in replacement for 12 now
I think they make a drop in replacement for 12 now
-
These are the bearings on the enthalpy and...
These are the bearings on the enthalpy and sensible wheels. little dinky sealed for life bearings. our annexair units are in there second season of operation. they use hot and chill water decks to...
-
02-13-2012, 07:42 PM
- Replies
- 86
- Views
- 3,393
I did'nt think Carrier liked underground lines. I...
I did'nt think Carrier liked underground lines. I have read many articles on this and listened to both sides of the argument. Some say CCH's work and some say they don't. Depending on the situation I...
-
Really? Did you mean carrier? Thats interesting...
Really? Did you mean carrier? Thats interesting because we were told by Trane that they were their reps. Some more info on that would be nice
-
02-10-2012, 10:34 PM
Thread: OLD G.E Split.. Need Compressor
by ambarton- Replies
- 26
- Views
- 1,266
Some of those old GE units were bullet proof. I...
Some of those old GE units were bullet proof. I can tell you where more than a couple dozen are still running while some other brands have come and gone more than once. if that were my unit and both...
-
02-06-2012, 10:37 PM
Thread: New System Charge Question
by ambarton- Replies
- 9
- Views
- 444
See there Mr. Homeowner, go ahead and feel that...
See there Mr. Homeowner, go ahead and feel that big line there. I got her really good and cold now. Did you say you had cash?
-
02-06-2012, 10:31 PM
Thread: New System Charge Question
by ambarton- Replies
- 9
- Views
- 444
I never get tired of hearing that one. LOL
I never get tired of hearing that one. LOL
-
02-06-2012, 10:24 PM
- Replies
- 23
- Views
- 3,851
Hey boss, whats this here plastic hickey cover'n...
Hey boss, whats this here plastic hickey cover'n up all them wire terminals? i don't know. uh hey boss, what!, what u want me to do with all this leftover wire? just tie it up somewheres dilbert?
-
02-06-2012, 09:54 PM
Thread: New System Charge Question
by ambarton- Replies
- 9
- Views
- 444
Did you not get the memo? All u gotta do is grab...
Did you not get the memo? All u gotta do is grab that big line there see and when she gets really good and cold well thats about right!:grin2:
-
02-06-2012, 09:41 PM
Thread: New System Charge Question
by ambarton- Replies
- 9
- Views
- 444
yes. some manufacturers want you to do just that....
yes. some manufacturers want you to do just that. open the suction valve to an evacuated lineset to boil off any liquid refrigerant in the compressor. york i think
-
02-06-2012, 09:36 PM
- Replies
- 6
- Views
- 555
when did you have this put in. a ph10 is a ten...
when did you have this put in. a ph10 is a ten seer unit?? am i missing something/
-
01-21-2012, 11:35 PM
Thread: Trane XL16i ice build up outside unit
by ambarton- Replies
- 17
- Views
- 1,344
a lot of folks here in the south like to set the...
a lot of folks here in the south like to set the defrost intervals on the max. i disagree with that because we see a lot of 30something degree rain which is hard on a heat pump. maby they need to...
-
01-21-2012, 11:28 PM
Thread: Carrier Blower Motor Question
by ambarton- Replies
- 15
- Views
- 1,360
If you feel that your capable of changeing the...
If you feel that your capable of changeing the motor yourself, go to a local hvac company and buy the motor. and afterwards for good measure schedule a inspection of your system i dont have a...
-
Thanks it has been a while since i have visited...
Thanks it has been a while since i have visited this website and a lot has changed. I have applied for (*) Sorry for the harshness, Andrew
-
02-18-2010, 10:53 PM
Thread: All out of ideas....
by ambarton- Replies
- 19
- Views
- 860
what was it during heating between acc and comp?...
what was it during heating between acc and comp? (superheat)
-
02-18-2010, 10:41 PM
Thread: All out of ideas....
by ambarton- Replies
- 19
- Views
- 860
it mite be a ***** but try reading superheat...
it mite be a ***** but try reading superheat between accumulator and compressor. that mite tell you if your flooding or not
-
02-18-2010, 10:32 PM
Thread: All out of ideas....
by ambarton- Replies
- 19
- Views
- 860
that makes sense but only if your running in ac...
that makes sense but only if your running in ac mode. rember a hp is sending hot gas to the air handler and converting to a liquid so any oil in the hot gas becomes mixed with the liquid and gets...
-
02-18-2010, 10:27 PM
Thread: reversing valve
by ambarton- Replies
- 1
- Views
- 305
70 degree water wow!
70 degree water wow!
-
02-18-2010, 10:25 PM
Thread: All out of ideas....
by ambarton- Replies
- 19
- Views
- 860
That is only when the evaporator is below the...
That is only when the evaporator is below the compressor and strictly for cooling only. where did they suggest putting the trap?
-
02-18-2010, 10:19 PM
Thread: All out of ideas....
by ambarton- Replies
- 19
- Views
- 860
where do they want you to put the inverted trap...
where do they want you to put the inverted trap on a heat pump?
-
02-04-2010, 07:55 PM
- Replies
- 11
- Views
- 2,220
a sheet of ice? where u cooling with it when...
a sheet of ice? where u cooling with it when that happened? you can get a unit with a better seer rating but finding a contractor that can install it and keep that rating may be harder and you mite...
-
01-29-2010, 12:42 AM
Thread: FS: Carrier Comfort Zone parts & Dampers
by ambarton- Replies
- 38
- Views
- 5,111
what u take for the whole lot?
what u take for the whole lot?
-
01-29-2010, 12:35 AM
Thread: Help -- Older Apartment
by ambarton- Replies
- 11
- Views
- 642
i have seen this in older apartments in the south...
i have seen this in older apartments in the south from the 60's. good when power was cheap and most people never had air conditioning before. bad in todays market. what is that rusty pipe thing...
Results 1 to 25 of 181