  1. Thread: Bad pucky

    by THEone2223
    Replies
    7
    Views
    761

    Same stuff I just spelt it wrong

    Same stuff I just spelt it wrong
  2. Thread: Bad pucky

    by THEone2223
    Replies
    7
    Views
    761

    Yes but it was like soup and one time I poured...

    Yes but it was like soup and one time I poured the moisture off and mixed but had clumpy result
  3. Thread: Bad pucky

    by THEone2223
    Replies
    7
    Views
    761

    Bad pucky

    What makes your pucky break down and build up water in to weeks if you don't use it all and reseal it
  4. Replies
    16
    Views
    657

    An 18 with 3 90's and 10 foot of pipe at least if...

    An 18 with 3 90's and 10 foot of pipe at least if possible
  5. Replies
    16
    Views
    657

    An 18 with 3 90's and 10 foot of pipe at least if...

    An 18 with 3 90's and 10 foot of pipe at least if posinle
  6. Replies
    16
    Views
    657

    Seconded should be a simple fix

    Seconded should be a simple fix
  7. Thread: New record

    by THEone2223
    Replies
    29
    Views
    1,496

    Most equipment manufactures recommend tolerance...

    Most equipment manufactures recommend tolerance for run capacitors be within 5% of equipment rating
  8. Replies
    2
    Views
    279

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  9. Got your back on the sheet metal was worried...

    Got your back on the sheet metal was worried everybody on this site was ruined with duct board
  10. Replies
    45
    Views
    3,541

    Metal duct should be insulated on the out side...

    Metal duct should be insulated on the out side not the inside fiberglass is a thing of the past within a duct system
  11. Replies
    45
    Views
    3,541

    It's been proven that fiberglass fibers lead to...

    It's been proven that fiberglass fibers lead to health issues and damage to electronics
  12. Replies
    45
    Views
    3,541

    What were the insulation levels like

    What were the insulation levels like
  13. Replies
    45
    Views
    3,541

    Next time I pan some thing in I will we insulate...

    Next time I pan some thing in I will we insulate everything from the out side we don't put any fiberglass within the duct system except what is in side the unit
  14. Replies
    45
    Views
    3,541

    Change outs still have meet code we have horrible...

    Change outs still have meet code we have horrible code inspectors here so people get away with doing installs and change out in correctly all the time when you do change outs that's something...
  15. Replies
    45
    Views
    3,541

    Did not know it was a change out and I would have...

    Did not know it was a change out and I would have replaced the duct bored with metal
  16. Replies
    45
    Views
    3,541

    Is there a code that requires it or do they do...

    Is there a code that requires it or do they do that so it is faster when they have to redo it after the hurricanes every year
  17. Replies
    45
    Views
    3,541

    Duct board is not very professional Hey...

    Duct board is not very professional Hey sheet-metal transition and a sheet-metal returned with look way more professional I have the same problem with people wanting to work with me due to the fact...
  18. Replies
    45
    Views
    3,541

    Not trying to be rude just so you know for future...

    Not trying to be rude just so you know for future reference chapter six of the imc by icc
  19. Replies
    45
    Views
    3,541

    That dryer vent is against code I don't know...

    That dryer vent is against code I don't know where your located but that won't fly in Oklahoma
  20. I'm a mechanical journeyman in the state of...

    I'm a mechanical journeyman in the state of Oklahoma and BPI certified energy auditor
  21. Thats funny how difficult is it to get a pro...

    Thats funny how difficult is it to get a pro status on hear i would like to have mine
  22. Than no LP comity to worry about check your local...

    Than no LP comity to worry about check your local code then ez your costumers mind bi explaining the concentration that would be needed for combustion to actually a cure. i assume the BBQ is located...
  23. There is no such code in the ICC code books you...

    There is no such code in the ICC code books you need to check local code but i don't think there will be is it LP or NG
  24. You could egg crate filter grill almost double...

    You could egg crate filter grill almost double the air flow.