Search:

Type: Posts; User: thermofridge

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    13
    Views
    750

    I think I would be looking at that blower motor....

    I think I would be looking at that blower motor. I have three of the Genius t6-11's. Not my favorite piece of equipment. I have learned that nobody in the USA knows anything about these machines so...
  2. Replies
    126
    Views
    2,928

    Ran into these...

    Ran into these http://www.lairdtech.com/products/aa-230-48-44-00-xx while servicing telecommunications equipment years ago. They work great. They were using them on battery compartments.
  3. Replies
    7
    Views
    507

    Thanks Nick, yes I have TEC's. 37 I believe. I do...

    Thanks Nick, yes I have TEC's. 37 I believe. I do have access to report builder. I will look tomorrow to see if I can see trends. Compared to ALC, this Siemens is in the stone ages.
  4. Replies
    7
    Views
    507

    Ken, not sure what you mean by TEC's. I have...

    Ken, not sure what you mean by TEC's. I have limited access. Wish I could see trends and logic. My IT department may have a higher level of access. Not sure how operator privileges are done in...
  5. Replies
    9
    Views
    416

    Flat white it is then. The flat is the important...

    Flat white it is then. The flat is the important part.
  6. Replies
    9
    Views
    416

    I love flat black. Fixes everything. Kinda like...

    I love flat black. Fixes everything. Kinda like duct tape.
  7. Replies
    7
    Views
    507

    Siemens Insight 3.11

    I have a 32000 sf. office building with Siemens Insight 3.11. Let me just say it. I don't like this program. As an operator, I was left with no ability to see the logic in this program. I am not a...
  8. That's tough, and tragic. If it were me, I would...

    That's tough, and tragic. If it were me, I would consider major work. Ask yourself why this is happening. You already know. Major heat gain. What you are proposing probably wont make much difference....
  9. Obviously there is exhaust air. There has to be....

    Obviously there is exhaust air. There has to be. Hopefully its not in an office building. We don't have enough info here to give advice. No reheat? New install or existing?
  10. I agree, EEV is the way to go.

    I agree, EEV is the way to go.
  11. Thread: New Here

    by thermofridge
    Replies
    17
    Views
    1,115

    Welcome. Read, lurk, whatever you need to do to...

    Welcome. Read, lurk, whatever you need to do to learn. You get out of it what you put into it.
  12. With that attitude Treestar, your Techs will...

    With that attitude Treestar, your Techs will appreciate you and your customers will appreciate them and that comes right back to you. Very few business owners understand that in my opinion. The way I...
  13. I asked our guys about this. (Amana and Goodman...

    I asked our guys about this. (Amana and Goodman coils are one and the same) No problems at all with the aluminum coils. ECM modules? Most manufacturers use the same exact modules and motors....
  14. Treestar, the beauty of this trade is that with...

    Treestar, the beauty of this trade is that with accurate measurements, you can troubleshoot a system pretty easily. Make sure your measurements are accurate and refer to post #2. It really is that...
  15. It is fine the way he did it but you could have...

    It is fine the way he did it but you could have done that yourself. When you call a company out, expect to pay the bill. Personally I would have removed the inverted trap and added a trap to the A/C...
  16. Replies
    30
    Views
    2,025

    Try 940 a month for just my wife and I. Caused me...

    Try 940 a month for just my wife and I. Caused me to look for and find my new job. I will be now paying 336 a month for much better coverage. That even includes vision and dental that I had no...
  17. Have them trap the A/C condensate pipe then vent...

    Have them trap the A/C condensate pipe then vent it immediately after the trap. ( so when it dries out it doesnt blow up the vertical pipe to the furnace trap.) Then get rid of that riser near the...
  18. That looks like the terminal strip for an AMVC or...

    That looks like the terminal strip for an AMVC or GMVC. If you have the original book, read it. If not, call the company that installed it and request a copy. It is all in there. There are additional...
  19. Excellent, Timebuilder. One more thing. The new,...

    Excellent, Timebuilder. One more thing. The new, black coated CSST piping has different requirements on bonding than the old yellow coated CSST did. I have been repeatedly told by inspectors and...
  20. Actually, as I said I am no electrician. I am...

    Actually, as I said I am no electrician. I am simply repeating what was told me from probably the best electrician I know. I too would like to know the reference as there is still much confusion on...
  21. Exactly, the key is that everything in the system...

    Exactly, the key is that everything in the system must be at the same potential. The only way to ensure that is to use the same bonding point. For the same reason, the conductor size should be the...
  22. Question 1: Not usually but probably not a bad...

    Question 1: Not usually but probably not a bad idea.
    Question 2: No, because that doesn't satisfy the reason the wire is there. The wire is required to bond the gas pipe to the grounding system. It...
  23. I believe they can be cured. The problem is that...

    I believe they can be cured. The problem is that if homosexuality is not seen as a problem then how can there be a solution? It originates in the brain where what we get out depends on what we put...
  24. I don't have a problem at all with two men or two...

    I don't have a problem at all with two men or two women loving each other. It's the sex that changes it .It's not natural, not right at all. Love has absolutely nothing to do with being gay. These...
  25. Replies
    27
    Views
    7,159

    I just ran into this the other day. System was...

    I just ran into this the other day. System was tripping on oil. Customer said they reset it a few times. I found it low on oil, running low oil pressure, and one of the TXVs (2 evaps) was starving(30...
  26. Poll: If it is in the crawlspace, how much damage would...

    If it is in the crawlspace, how much damage would occur it the drain gets plugged? I would be more concerned about the furnace condensate line myself. Usually when the heat is on inside, the cold is...
  27. Replies
    15
    Views
    1,345

    So you are dealing with cap tubes. I would...

    So you are dealing with cap tubes. I would suggest reading information from SUPCO. They are the cap tube pros. Good luck.
  28. Sticky: I can't imagine your hurt but you must put your...

    I can't imagine your hurt but you must put your feelings aside and realize that she is at peace now. You will heal. She suffers no more. Just remember.
  29. Replies
    7
    Views
    743

    701. It covers all conditions if the cap tube is...

    701. It covers all conditions if the cap tube is placed correctly. I usually make a bulb out of the first 12 inches of tube and insert into the evaporator. Have very few problems. No freeze ups. For...
  30. Walker pisses alot of people off but thats...

    Walker pisses alot of people off but thats because he is a realist. Look at everything he does and it makes sense. The problem is that those negatively affected have narrow vision. Hell, I had narrow...
  31. Replies
    471
    Views
    51,623

    https://www.youtube.com/watch?v=trinU3VD1Zo ...

    https://www.youtube.com/watch?v=trinU3VD1Zo gotta be a crazy refer tech to understand
  32. Replies
    851
    Views
    60,969

    And another thing, Had a 17 hour day yesterday...

    And another thing, Had a 17 hour day yesterday and just said screw it today. I couldn't do it. Too exhausted, I took the day off today. This marks the beginning of the end. I've never felt so...
  33. Replies
    851
    Views
    60,969

    After reading all this crap I really don't give a...

    After reading all this crap I really don't give a s**t except PHM's contributions. The guy always has an intelligent post. ahh who am I kidding, nobody cares.
  34. Use an aquastat on the incoming boiler line to...

    Use an aquastat on the incoming boiler line to lock out the heat strips unless the water cools off.
  35. Replies
    18
    Views
    1,671

    You are the future. Be humble, work hard and soon...

    You are the future. Be humble, work hard and soon you will be rewarded. Like my signature says...............
  36. Replies
    3
    Views
    353

    L1 and L2 are connected by the primary winding....

    L1 and L2 are connected by the primary winding. So, yes, you would see 120V to ground on L2 if the L2 fuse was blown. You would not see voltage between L1 and L2 as they are now the same line.
  37. Replies
    38
    Views
    5,451

    I agree with J.P. I have filtered refrigerant...

    I agree with J.P. I have filtered refrigerant like this many times and never once had moisture problems. Like he said, charge it back as a liquid and it also eliminates non condensibles.
  38. Compound compressors. I guess it would have gone...

    Compound compressors. I guess it would have gone faster if I could have identified the source of the liquid faster. I kept thinking it had to be coming from one of the circuits and it wasted alot of...
  39. What is the fastest way to get a flooded rack pumping?

    Had a real PITA. 4 compressor compound Carlyle low temp. All compressors and oil reservoir flooded with liquid. 407a, -10 ambient, midnight. Had all i could handle trying to get it going again....
  40. Humidity is relative. In other words, as the...

    Humidity is relative. In other words, as the temperature changes, so does Relative Humidity. Warm air holds more water than cold air. So, as air is heated, the humidity decreases relative to its...
  41. You need to know the gas pressure. Do you have a...

    You need to know the gas pressure. Do you have a magnahelic gauge? An electronic manometer? Also, did you remove the burner cover and make sure the screen is clean? Check the orifice for obstruction.
  42. I would give them about 2 weeks. Then that cooked...

    I would give them about 2 weeks. Then that cooked POE oil will have everything plugged up. This is gonna be bad. I had a 24 ton Carrier RTU lose all 4 condenser fan blades because the set screws were...
  43. Guys, all of this effort and time spent on...

    Guys, all of this effort and time spent on learning something new instead of laughing at this poor guy and maybe we all become better techs. Just saying.
  44. I service 9 supermarkets. Refrigeration and HVAC....

    I service 9 supermarkets. Refrigeration and HVAC. Plus a wide range of smaller commercial accounts. It has been my experience that a new, young manager will want to be hands on with his racks. I will...
  45. Why did you recharge it? Was there a leak? Did...

    Why did you recharge it? Was there a leak? Did you fix it? Who cares about the valve, is the cooler working?
  46. Replies
    133
    Views
    12,532

    When you start to stack customers like that, you...

    When you start to stack customers like that, you know you are doing fine. That is what keeps me going. Never be satisfied with what someone tells you, go find out for yourself. Everyone does things...
  47. Replies
    133
    Views
    12,532

    Sometimes a line set is long enough and receiver...

    Sometimes a line set is long enough and receiver small enough that the charge will not fit into the receiver when the receiver liquid line is seated closed. VIP99, if the solenoid is near the evap....
  48. Replies
    52
    Views
    8,731

    Hisser- big leak Weeper- small leak Crank it...

    Hisser- big leak
    Weeper- small leak
    Crank it up- time to get to work/ make some money
    Blow the b*tch- turn on the nitro flow
    Gas-freon
  49. Why is the air coming in and not going out? Is it...

    Why is the air coming in and not going out? Is it always the same or does it get worse when it is colder?
    Ask yourself this question. Why is the air entering my house through my kitchen exhaust...
  50. Replies
    39
    Views
    5,702

    When you do find a leak, don't assume you are...

    When you do find a leak, don't assume you are done. JP's method is good and should be followed to the end whether you find a leak before you get there or not. By being thorough, we have drastically...