04-25-2013, 09:26 PM
- Replies
- 16
- Views
- 379
Does the drive itself accept your fieldbus? Lon?...
Does the drive itself accept your fieldbus? Lon? Which can tell you the speed?
-
04-25-2013, 08:26 PM
- Replies
- 16
- Views
- 379
Cutler hammer/ johnson controls drives will...
Cutler hammer/ johnson controls drives will accept floating control (motor pot up pot down)
-
04-25-2013, 07:40 PM
- Replies
- 16
- Views
- 379
I used one kele pwa-1t this week with good...
I used one kele pwa-1t this week with good results.
-
04-22-2013, 12:15 PM
Thread: Help with Niagara Bformat text
by DanInBoston- Replies
- 1
- Views
- 154
Help with Niagara Bformat text
I have an enumeration set which Id like to add an enum COS alarm extension. I want to include the enumerated text in the off normal alarm text.
For example, 0 = Normal, 1= Low Pressure, 2= Fan... -
04-21-2013, 11:56 AM
Thread: Vykon JACE-200 no station
by DanInBoston- Replies
- 14
- Views
- 435
Ok you should see the one and only station on...
Ok you should see the one and only station on your jace. Delete it and then go to Tools, New Station. Hope this helps.
-
04-21-2013, 11:26 AM
Thread: Vykon JACE-200 no station
by DanInBoston- Replies
- 14
- Views
- 435
Are you in the platform of your computer? Make...
Are you in the platform of your computer? Make sure you are in the platform of your jace
-
04-21-2013, 10:43 AM
Thread: Vykon JACE-200 no station
by DanInBoston- Replies
- 14
- Views
- 435
I would make a new station. I believe its Tools...
I would make a new station. I believe its Tools --> New Station. You may need to be in the app director
-
04-15-2013, 03:13 PM
Thread: JCI FX Bacnet
by DanInBoston- Replies
- 1
- Views
- 140
Make sure there are no duplicate bacnet...
Make sure there are no duplicate bacnet instances. I assume you're using a RS485 expansion?
Keep an eye on the busy time on the trunks with that many controllers you may need to slow polling down -
04-08-2013, 07:11 PM
Thread: JCI Dealer talk forum??
by DanInBoston- Replies
- 13
- Views
- 640
Apparently I signed up and now I am getting...
Apparently I signed up and now I am getting emails asking me to update my "status"... I looked around and its pretty useless
-
04-01-2013, 05:55 AM
Thread: Bacnet Comm error- ACH550, AX
by DanInBoston- Replies
- 15
- Views
- 628
Can you send me the info as well as I'm actually...
Can you send me the info as well as I'm actually in need of a fix
-
03-31-2013, 11:47 AM
Thread: Bacnet Comm error- ACH550, AX
by DanInBoston- Replies
- 15
- Views
- 628
The field server controller points for the Camus...
The field server controller points for the Camus boilers is going in and out of fault quickly. I saw this same issue on the PCG controller when I used a low bacnet instance number... (104). Changing...
-
03-29-2013, 04:44 PM
Thread: Bacnet Comm error- ACH550, AX
by DanInBoston- Replies
- 15
- Views
- 628
a +, -, and Common are landed. The shield is back...
a +, -, and Common are landed. The shield is back wrapped.... When the shield was connected, I saw nothing on the trunk.
-
03-29-2013, 01:17 PM
Thread: Bacnet Comm error- ACH550, AX
by DanInBoston- Replies
- 15
- Views
- 628
Bacnet Comm error- ACH550, AX
I'm getting these Bacnet comm errors from an ABB ACH 550 connected over 22/3 @19,200 baud. Theres only 5 controllers on this 25 foot fieldbus. I only have added 11 points from this VFD thus far. Some...
-
03-27-2013, 07:39 PM
Thread: JCI FX Customer Training Manual ???
by DanInBoston- Replies
- 2
- Views
- 267
I can't even get a sequence of operations for...
I can't even get a sequence of operations for their application wizards never mind training material
-
02-27-2013, 03:50 PM
Thread: PCV1620 and bacnet device instances
by DanInBoston- Replies
- 4
- Views
- 198
I think I should be able to do this using the...
I think I should be able to do this using the read/write attributes function in PCT but I keep getting an error after changing the Bacnet ID and clicking write attributes : "No attributes are defined"
-
02-27-2013, 02:57 PM
Thread: PCV1620 and bacnet device instances
by DanInBoston- Replies
- 4
- Views
- 198
PCV1620 and bacnet device instances
Is it possible to change the device instance on a PCV1620 once its been programmed (without re-downloading to the box)? I have duplicate device instances on different fieldbuses and different...
-
02-23-2013, 07:59 AM
- Replies
- 5
- Views
- 185
Thanks Dan... The factory rep sent me a link to...
Thanks Dan... The factory rep sent me a link to the pulse option doc which didn't exactly apply when I asked him some questions...
Thanks for being thorough -
02-22-2013, 07:36 PM
- Replies
- 5
- Views
- 185
359651359661 Heres the logic. The data is in...
359651359661
Heres the logic. The data is in fault because I ran the station offline. -
02-22-2013, 10:31 AM
- Replies
- 5
- Views
- 185
anyone?
anyone?
-
02-20-2013, 04:23 PM
- Replies
- 5
- Views
- 185
Help with intellimeter A277 demand meter in AX
I have several Intellimeter A-277 electrical meters that I must connect to a FX60.
I have these pulse inputs tied into a PCG1711 controller and setup as accumulators. I have inferred that the... -
12-21-2012, 05:43 PM
- Replies
- 10
- Views
- 909
The PT link is wattmaster. I would try to call...
The PT link is wattmaster. I would try to call them with any questions regarding the PT link and points communicated over it.
-
11-02-2012, 03:47 PM
- Replies
- 4
- Views
- 530
Fixed. Tech support had me hardcode the JACES...
Fixed. Tech support had me hardcode the JACES bacnet network # into the 812u via BacView. BacView Password was 09876
-
11-01-2012, 01:54 PM
- Replies
- 4
- Views
- 530
Trouble w Mammoth RTU I/O Pro 812U Bacnet
I am trying to connect an FX60 to a mammoth RTU with a I/O Pro 812u. I am connecting with a 3' piece of wire from the internal RS485 card to the port2a (net+, net-). I have setup bacnet correctly and...
-
10-04-2012, 07:00 AM
Thread: FXVMA Questions
by DanInBoston- Replies
- 7
- Views
- 633
I should add that cycling power or recalibrating...
I should add that cycling power or recalibrating the DP does not help when the controller is reading supply flow of zero.
When the controller is reading zero in these cases, I am able to measure... -
10-04-2012, 06:53 AM
Thread: FXVMA Questions
by DanInBoston- Replies
- 7
- Views
- 633
FXVMA Questions
I have installed over 300 FXVMAs (N2). I am using the FX Builder Application Wizard to generate APDs for terminal boxes. These are mostly fan powered electric heat and cool only vavs. There are over...