  1. Replies
    13
    Views
    470

    I think I'm finally on the right track. Again no...

    I think I'm finally on the right track. Again no matter what I type for the PI parameters of the PID I would still get the same result. I had the prop band set to -400 and the integration at .5 but...
  2. Replies
    13
    Views
    470

    Is there anyone who can take a look at this DX...

    Is there anyone who can take a look at this DX program for me? It doesn't seem to matter what I put in for the prop band or for the integral I get the same result
  3. Replies
    13
    Views
    470

    I have been using integration and increasing the...

    I have been using integration and increasing the prop band in the PID and it has been working better but I still get the same result. I'm going to re-download it next time I'm at that building
  4. Replies
    13
    Views
    470

    I made the prob band -110 with an integral time...

    I made the prob band -110 with an integral time of 0.02. I don't think I've ever had to make the prop band on a DX9100 that low before. The reaction time is definitely slower but the PID will ramp...
  5. Replies
    13
    Views
    470

    I'm thinking this is a problem with the PID now. ...

    I'm thinking this is a problem with the PID now. This DX9100 is connected to an FX70 and all of the points are mapped in. I have been able to locate the main hot water PID output point that is...
  6. Replies
    13
    Views
    470

    Its being shut down through software. There is a...

    Its being shut down through software. There is a boiler status point for each boiler that you can watch change along with the command.
  7. Replies
    13
    Views
    470

    DX9100 PID Issues?

    I have a DX9100 controlling 3 boilers with an individual On/Off command as well as a 0-10v signal to modulate the flame for each boiler for a hot water system. Everything seems to be fine. On a...
  8. Replies
    1
    Views
    193

    I don't have any experience with it, but a...

    I don't have any experience with it, but a company that works in the same office park as me has. I've talked with the maintenance crew about them and have never heard of any problems. I've been...
  9. check out the docAndoverInfinity.pdf

    check out the docAndoverInfinity.pdf
  10. Replies
    3
    Views
    383

    What are the devices you're trying to connect and...

    What are the devices you're trying to connect and program to? You shouldn't need BBMD to do that. The settings you are looking for are under Bacnet Network>Bacnet Comm>Network>IP Port. Make sure...
  11. You should be able to manually edit the N2 points...

    You should be able to manually edit the N2 points table and change it to what you want. Or do you have the original .prn file from the unt? Open that in word pad and see what it's mapped in as in...
  12. Replies
    3
    Views
    355

    Do you have the vykon pro module installed? ...

    Do you have the vykon pro module installed? There is a "tooltip" binding that you can add to a bound label that will do what you are looking for.
  13. Replies
    9
    Views
    548

    Dang, I have about 8 of the FX60E's installed in...

    Dang, I have about 8 of the FX60E's installed in a few different buildings. This is the first one to go. I'm wondering if the brownout caused this. I think I'm going to look for a surge protector...
  14. Replies
    9
    Views
    548

    I thought there was an issue with the FX60's that...

    I thought there was an issue with the FX60's that had batteries. Wasn't that the purpose of eliminating the batteries in the first place? Now Tridium is making batteries in the FX60s again?
  15. Replies
    9
    Views
    548

    Yes I have tried that. This is an FX60E, there...

    Yes I have tried that. This is an FX60E, there isn't a battery in it. I also had to cycle power when connecting to the serial shell. I just got word back from tech support about this. It looks...
  16. Replies
    9
    Views
    548

    FX60 Java Error?

    There was a black out in one of the buildings that we service the other day. The Jace went offline but never came back when the power came back. The lights on the Jace are blinking like normal...
  17. Replies
    3
    Views
    349

    I was working on the 2nd Jace today. It is just...

    I was working on the 2nd Jace today. It is just as slow loading the point data so it looks like the Niagara network is working properly. I looked at the resource manager on the 2nd Jace too. The...
  18. Replies
    3
    Views
    349

    FX70 through Niagara Network

    I have a site that has 2 FX70s without a server. FX70 number 1 has all of the graphics and trends etc. It also pulls all of the data from FX70 number 2 through the Niagara Network. These 2 FX70s...
  19. Replies
    6
    Views
    594

    Update: I was on site last week looking at...

    Update:

    I was on site last week looking at this again. There are a total of 3 speed drives that share the same 4-20 ma signal wired in series. I took a resistance reading from the two wires...
  20. Replies
    6
    Views
    594

    Thank you for all of the input. I'm going to see...

    Thank you for all of the input. I'm going to see if I can convert it to 0-10V
  21. Replies
    6
    Views
    594

    Thanks JCIman Ill give that a try and see what...

    Thanks JCIman Ill give that a try and see what happens
  22. Replies
    6
    Views
    594

    VFD output not going to 100%

    I replaced an old Metasys AHU controller that was controlling some pumps on a water source heat pump loop with a new PCG controller. Everything is wired but the problem I'm having is that the speed...
  23. Replies
    34
    Views
    3,187

    Are you using an FX70? There ended up being a...

    Are you using an FX70? There ended up being a recall on a lot of them. Right around when I started this thread
  24. Replies
    13
    Views
    964

    I ended up just leaving it the way it is from the...

    I ended up just leaving it the way it is from the factory. Whatever points are in the heat pump is what I'm going to map in. No matter what I did I couldn't get the microtech boards to update or...
  25. Replies
    4
    Views
    332

    I ended up changing the Lon board again. This is...

    I ended up changing the Lon board again. This is the 3rd board but its finally communicating on the network.
  26. Replies
    4
    Views
    332

    I'm using an fx60 to discover and commission. I...

    I'm using an fx60 to discover and commission. I was thinking about direct connecting but thought that might be a waste of time
  27. Replies
    4
    Views
    332

    Lon Heat Pump Discover

    I'm having trouble discovering a heat pump on a lon network. There was a new McQuay heat pump added to an existing lon network. I took the comm from the closest heat pump and daisy chained it to...
  28. Replies
    13
    Views
    964

    ruchc03, I can't make it past the first step...

    ruchc03,

    I can't make it past the first step in your instructions. I got the files from the factory for program ID 57 48 50 45 31 42 00 00. They sent me the XIF file, the heat pump comes in as...
  29. Replies
    13
    Views
    964

    No one has seen this message before? ...

    No one has seen this message before?

    http://i.imgur.com/DTZEWV5.jpg
  30. Replies
    4
    Views
    373

    I know they're practically the same thing but I...

    I know they're practically the same thing but I haven't seen PCT do this. I haven't used CCT in a while but that always annoyed me too
  31. Replies
    12
    Views
    1,206

    License Manager in the platform

    License Manager in the platform
  32. Replies
    13
    Views
    964

    Has anyone seen the message "Not a Station VM"...

    Has anyone seen the message "Not a Station VM" before or know what it means?
  33. Replies
    40
    Views
    4,223

    Isn't Lon the protocol that's expensive? I...

    Isn't Lon the protocol that's expensive? I thought you had to buy Lon credits depending on how many nodes you want to integrate to? I don't mind Lon and have done several integrations with the jace...
  34. Replies
    13
    Views
    964

    I'm trying to use the AppDownload button to...

    I'm trying to use the AppDownload button to download the .NXE file I got from McQuay tech support. I keep getting this error though.

    http://i.imgur.com/DTZEWV5.jpg
  35. Replies
    3
    Views
    321

    I'm not familiar with Phoenix or field servers...

    I'm not familiar with Phoenix or field servers controls but I wouldn't be surprised if they have a Lon to bacnet gateway

    http://store.fieldserver.com/ez-gateway/
  36. Replies
    13
    Views
    964

    Do I need any special cables for NodeUtil?

    Do I need any special cables for NodeUtil?
  37. Replies
    13
    Views
    964

    Lon Heat Pump Integration

    I have a building with some older lon McQuay heat pumps. I have no problem communicating and seeing the points in them with an FX Jace. The problem I'm having is with the McQuay heat pumps that use...
  38. I doubt I would get the exact same deal with...

    I doubt I would get the exact same deal with another employer and I know unions are different in each state. Overtime depends on the job but it's typically after 8 hours. And in the temperature...
  39. I'm not in a union and I get all of those...

    I'm not in a union and I get all of those benefits. I also get to keep my benefit money and hourly wage when I work on a prevailing wage job. So why join a union?
  40. You can check what the jace is licensed for by...

    You can check what the jace is licensed for by looking at the license manager in the platform
  41. Do you know what version you updated it to? Was...

    Do you know what version you updated it to? Was the jace licensed for the update?
  42. What does a union do for an employee other than...

    What does a union do for an employee other than take their money?
  43. Thread: FOXS in AX

    by Igotworms
    Replies
    15
    Views
    898

    Can you update the jace to 3.8?

    Can you update the jace to 3.8?
  44. Replies
    5
    Views
    713

    Either way it's still easy as long as you have...

    Either way it's still easy as long as you have workbench. Just go to the station copier, there is an option to change it there. Here is the link to change the log in page as prtadko was describing....
  45. Replies
    9
    Views
    872

    I know the feeling

    I know the feeling
  46. Replies
    9
    Views
    872

    Tell us how you really feel

    Tell us how you really feel
  47. Replies
    8
    Views
    588

    Do you have workbench? Are you able to connect...

    Do you have workbench? Are you able to connect to the platform for the jace?
  48. Replies
    12
    Views
    1,229

    I believe the firmware rev is 3.03. I can see...

    I believe the firmware rev is 3.03. I can see this when I scan for devices on the N2 trunk. I have the all of the point mappings converted from the old NCM to the new FX70 and the points list. ...
  49. Replies
    12
    Views
    1,229

    Also, when I create a new AHU configuration with...

    Also, when I create a new AHU configuration with what I believe is the correct Q/A session, HVAC Pro will give me the option to "Import AHU DOS Config." When I select that it is now looking for a...
  50. Replies
    12
    Views
    1,229

    I finally got around to replacing this controller...

    I finally got around to replacing this controller with a new PCG. I have the AHU controller on my desk in my office hooked up to a power supply and HVAC Pro. I go to the upgrade option in HVAC Pro...