Search:
Type: Posts; User: cynic
Search: Search took 0.01 seconds.
-
07-27-2005, 08:58 PM
Thread: Hoshizaki km-450 MAB
by cynic- Replies
- 14
- Views
- 2,007
How big is the bin ?
How big is the bin ?
-
11-17-2004, 07:13 PM
Thread: hot water heating
by cynic- Replies
- 16
- Views
- 2,083
Think you are right Noel.... wonder if that air...
Think you are right Noel.... wonder if that air vent has anything to do with it filling up.
-
11-09-2004, 08:26 PM
Thread: Call Back-A-Rama
by cynic- Replies
- 19
- Views
- 1,149
I love a challenge but following people around...
I love a challenge but following people around too much does tend to get depressing. A consultant was in where I work and said callbacks and non billable hours resulting from them were the...
-
11-09-2004, 06:59 PM
Thread: TRASH ROOMS
by cynic- Replies
- 4
- Views
- 1,136
Low bid ? :) the cooler the better we run them...
Low bid ? :) the cooler the better we run them about the same temps as a regular walk in cooler, and all of them are basicly walk in coolers that happen to be full of trash or in a few cases dead...
-
10-14-2004, 06:33 PM
Thread: Submarine Pool
by cynic- Replies
- 11
- Views
- 740
dunno how much more damage salt water would do...
dunno how much more damage salt water would do but had a resturant where the basement turned into a swimming pool, replaced all the fan motors and relays made new fan shrouds and all is still running...
-
10-14-2004, 06:25 PM
- Replies
- 13
- Views
- 930
Cam and microswitch setup like on the older...
Cam and microswitch setup like on the older scottsman cubers. slow running motor with a disk mounted to it,then cut in as many spaced out areas as needed to get the switch to make and break when...
-
09-29-2004, 10:14 PM
Thread: Head Pressure Controls
by cynic- Replies
- 10
- Views
- 796
Multi circuit condensors is probably why they do...
Multi circuit condensors is probably why they do it that way. That and have to agree with cost also 2 stats and the dual input p66 are cheaper than the 4 pressure controls plus p66 that would be...
-
09-27-2004, 10:39 PM
Thread: VFD savings calculation software
by cynic- Replies
- 3
- Views
- 3,180
Not sure but this might help ...
Not sure but this might help
http://www.alliantenergy.com/stellent/groups/public/documents/pub/bus_exp_eff_012399.hcsp -
09-25-2004, 07:06 PM
Thread: Service valve gland nut tool
by cynic- Replies
- 16
- Views
- 2,537
If you cant find one deep socket and a grinder...
If you cant find one deep socket and a grinder can make one.
-
09-23-2004, 09:07 PM
- Replies
- 13
- Views
- 1,544
Dunno if hot gas would be a good idea on a heat...
Dunno if hot gas would be a good idea on a heat pump. does the unloader actually work ? I have seen more than one carrier that had something stuck under the unloader solonoid right from day one...
-
09-23-2004, 08:56 PM
Thread: Cleaning corrosion
by cynic- Replies
- 5
- Views
- 732
Might want to leave it alone, sometimes what...
Might want to leave it alone, sometimes what looks bad is actually doing a better job than paint would. Whats the evaporater made of ? fish don't like copper.
-
09-23-2004, 08:50 PM
Thread: Tech support charge
by cynic- Replies
- 38
- Views
- 1,948
Anyone care to imagine what the vast majority of...
Anyone care to imagine what the vast majority of calls to GE tech support are ? Hotel ptacs and who looks at them first ? Then again if they wanted to pay for my time on hold..... :)
-
09-21-2004, 10:05 PM
Thread: leak sealant for refrigeration system?
by cynic- Replies
- 19
- Views
- 2,091
well if its leaking how do you follow the...
well if its leaking how do you follow the instructions ??? Have already found and repaired leaks on 2 units that someone put that stuff in one did have a dead compressor due to a blocked drier and...
-
09-18-2004, 10:00 AM
Thread: got rear ended!
by cynic- Replies
- 30
- Views
- 1,473
I got sideswiped by a schoolbus last winter...
I got sideswiped by a schoolbus last winter getting paid for the time was not even an issue, same thing when a van dies even on overtime. Remind me to thank my boss for not being a total A$$ and...
-
09-18-2004, 09:37 AM
Thread: AAON rooftop.....removing condenser
by cynic- Replies
- 15
- Views
- 1,555
Ask the brilliant engineer who placed it there :)...
Ask the brilliant engineer who placed it there :)
Is there enough space to put a duct on the "return" and pull air from above roofline without killing condensor airflow ? or a combination of a... -
08-17-2004, 06:29 PM
Thread: Painting Natural Gas Pipes in Basement.
by cynic- Replies
- 12
- Views
- 4,174
Lable the pipes, see yellow and grey mostly
Lable the pipes, see yellow and grey mostly
-
08-17-2004, 06:16 PM
Thread: Psychotic Dispatchers ...
by cynic- Replies
- 25
- Views
- 1,270
No sane person would do it where I work :)
No sane person would do it where I work :)
-
08-17-2004, 06:01 PM
Thread: Mr. Slim Problems
by cynic- Replies
- 11
- Views
- 4,734
http://www.mrslim.com/home.asp roam around...
http://www.mrslim.com/home.asp
roam around and download the service info for it. old page it was eaiser to find but the info is still there. -
08-16-2004, 06:46 PM
Thread: blowing out the return
by cynic- Replies
- 14
- Views
- 1,268
Ran into that last summer not one unit... all 6...
Ran into that last summer not one unit... all 6 on the roof of a strip mall ducted backwards.
-
08-16-2004, 06:20 PM
Thread: How to clean Trane coils?
by cynic- Replies
- 11
- Views
- 1,262
Sonc... havent had the misfortune of seeing one...
Sonc... havent had the misfortune of seeing one of those yet. have had the misfortune of changing a few of those tandem bristols though.
-
08-15-2004, 09:50 AM
Thread: How to clean Trane coils?
by cynic- Replies
- 11
- Views
- 1,262
what kind of york has split coils ? only yorks I...
what kind of york has split coils ? only yorks I have seen with them are the older residential ones. If its a coil like the tranes and carriers that need to be split there is no way to get them...
-
08-09-2004, 06:44 PM
Thread: BEACON SYSTEM
by cynic- Replies
- 7
- Views
- 914
They have changed sensors/thermistors yet again...
They have changed sensors/thermistors yet again now they are all white. They are so reliable if one is bad I just toss in the 3 or 4 other ones while in the coil.
-
08-07-2004, 10:09 AM
Thread: Sporlan Sold?
by cynic- Replies
- 12
- Views
- 1,300
uh oh well it could have been worse imagine if...
uh oh well it could have been worse imagine if emerson bouyght them :)
-
08-07-2004, 10:07 AM
Thread: Acid cleaning condensers
by cynic- Replies
- 8
- Views
- 935
A regular steel bolt ? thats a good idea need...
A regular steel bolt ? thats a good idea need to try it on the next one I do.
-
08-07-2004, 09:58 AM
Thread: coffin freezer
by cynic- Replies
- 3
- Views
- 1,530
Have rewired a couple that someone thought the...
Have rewired a couple that someone thought the fans should have been off during defrost. Terminator/overtemp limit shut off defrost before coil was cleared of ice and bottom layer of product was...
Results 1 to 25 of 152