TRANE XR 15 System - Which furnace should I get?
Is XT80 ok , or do i need the XV80?
location is North Texas - I do not need the 2 stage heating feature
Is there any advantage on the cooling mode to get the XV
Is having variable speed... -
07-23-2012, 03:13 AM
- Replies
- 1
- Views
- 293
What is the correct sealant between coil and furnace
My coil was sealed to the furnace with silicone and there is air leaking
did the install guys use the right stuff and what can / should be done to fix? -
07-23-2012, 03:10 AM
- Replies
- 20
- Views
- 1,468
the dips that installed the system left all of...
the dips that installed the system left all of the dip switches on default settings
so, since they never came out, or even called me back all week, I just put on my big boy pants and removed the... -
07-19-2012, 09:00 PM
- Replies
- 20
- Views
- 1,468
howdy I will get you some pictures of outside...
howdy
I will get you some pictures of outside unit and inside unit install
there was no central air in house before install on a 1950's house.
there was a centrally located coat closet which... -
07-19-2012, 08:21 PM
- Replies
- 20
- Views
- 1,468
I do not know what you mean "correct design...
I do not know what you mean "correct design temperature"
today was 102 and Saturday it will be 105
The installing company said that 95 used to be the design temperature , but after last summer... -
07-19-2012, 07:07 PM
- Replies
- 20
- Views
- 1,468
Hi guys ... thank you for bothering to reply to...
Hi guys ... thank you for bothering to reply to my thread
you are right the delta T needs to be measured inside supply plenum , just above the coil to get a more accurate reading
supply plenum... -
07-19-2012, 04:29 AM
- Replies
- 20
- Views
- 1,468
Hi...its not a barn ...but I do have some...
Hi...its not a barn ...but I do have some chickens in my yard
heat load was performed and it came out to 3 tons
I am happy with the system and do not think it is oversized
the unit runs on 2... -
07-18-2012, 05:01 PM
- Replies
- 20
- Views
- 1,468
I do not understand what you are saying ? ...
I do not understand what you are saying ?
Oversized?
The manual J indicated 3 tons
it is 98 degrees currently and holding 79 on first stage
can airflow be adjusted by tech to a lower cfm... -
07-18-2012, 04:10 PM
- Replies
- 20
- Views
- 1,468
Hi, thanks .. I've been lurking on these forums...
Hi, thanks .. I've been lurking on these forums for a while - listening and learning from you Pros.
Yes I am comfortable for the first summer since I bought the house in 2004.
I had a broken... -
07-18-2012, 03:44 PM
- Replies
- 20
- Views
- 1,468
Need Help with My new install - Trane XL20i system
Hello and thank you for all that you do!
I have just had a complete TRANE XL20i system installed in my home.
The system is as follows :
XL20i 4 ton 2 stage
XV 80 Furnace
Trane comfort...