05-16-2013, 06:43 AM
Thread: Will excessive evap load cause
by SouthTex- Replies
- 6
- Views
- 280
forget the indoor temp if you are looking for...
forget the indoor temp if you are looking for evap load in the heat mode, the condenser is now the evap. Have found in years past on some units we would cycle the outdoor fan in the heat mode by...
-
05-10-2013, 06:43 AM
Thread: using gauges on multipal refrigerants
by SouthTex- Replies
- 13
- Views
- 562
Why I like the digital gauges all the imformation...
Why I like the digital gauges all the imformation is built in
-
05-10-2013, 06:36 AM
Thread: Bryant blower motor
by SouthTex- Replies
- 16
- Views
- 448
sometimes alignment of the puller can be a...
sometimes alignment of the puller can be a problem, on 1/2" shafts put a copper coupling on the shaft of the motor, sure makes it easier
-
05-09-2013, 06:43 AM
Thread: Siemans 24v contactor coil keeps failing
by SouthTex- Replies
- 4
- Views
- 262
If it has a multi tap transformer make sure it is...
If it has a multi tap transformer make sure it is on the right tap. Have seen where they are taped for 230 volt and there is 208 being supplied. Will make a difference when the contactors pull in. ...
-
04-06-2013, 07:20 AM
Thread: off cycle sluging
by SouthTex- Replies
- 9
- Views
- 312
crankcase heater will keep the liquid refrigerant...
crankcase heater will keep the liquid refrigerant out of the crankcase but will do nothing to keep large amounts of refrigerant from slugging that has accumulated in the coil or in the lineset. I...
-
04-03-2013, 06:36 AM
Thread: Inspection camera recomendations
by SouthTex- Replies
- 6
- Views
- 370
Recently picked one up at Home Depot called the...
Recently picked one up at Home Depot called the whistler for under a hundred. First day out found 2 dirty evap coils going thru the high limit, of furnaces paid for itself right then and there.
-
03-24-2013, 07:08 AM
- Replies
- 21
- Views
- 1,537
Don't forget checking the temp drop accross the...
Don't forget checking the temp drop accross the indoor coil, I have seen units that have the correct subcooling / superheat but still have a low temp drop.
-
03-06-2013, 08:09 AM
- Replies
- 6
- Views
- 438
Sounds as tho there is a Lovejoy coupling. Get...
Sounds as tho there is a Lovejoy coupling. Get shaft size and you should be able to find a replacement. The tough part is getting the old one to move, sanding and lots of wd 40. May have to pull...
-
01-25-2013, 06:38 AM
Thread: carrier clo
by SouthTex- Replies
- 1
- Views
- 316
install a icm voltage monitor and set it up for...
install a icm voltage monitor and set it up for auto rest
-
11-22-2012, 07:55 AM
Thread: Which socket wrench do you have ?
by SouthTex- Replies
- 48
- Views
- 3,962
Keep a set of gear wrenches to 9/16" in bag along...
Keep a set of gear wrenches to 9/16" in bag along with set of Dewalt magnetic nut setter to 1/2" for my impack driver. Very seldom have to use sockets any more. Keep an extension for the nut...
-
08-12-2012, 07:22 AM
Thread: trane and york filter drier
by SouthTex- Replies
- 7
- Views
- 980
You are right it is a filter drier, had a...
You are right it is a filter drier, had a customer that had 3 compressor failures and the company doing the work thought it was a muffler and never changed it. It was a split York heat pump figured...
-
08-12-2012, 07:08 AM
- Replies
- 28
- Views
- 2,320
You said this was a heat pump outdoor, would not...
You said this was a heat pump outdoor, would not use a solenoid with a heat pump with out some specical consideration for the heating cycle. Is there a suction acculator installed between the...
-
07-28-2012, 06:59 AM
Thread: welded contactor
by SouthTex- Replies
- 17
- Views
- 1,583
Had similar problem, Rheem unit with 4...
Had similar problem, Rheem unit with 4 compressors set up for 2 stages, thermostat 150 ft run. When contactors pulled in they chattered, especially if calling for both stages, low voltage dropped to...
-
10-06-2011, 08:20 AM
Thread: leaky furdowns
by SouthTex- Replies
- 17
- Views
- 742
is the coil clean?
is the coil clean?
-
10-04-2011, 08:35 AM
Thread: Anyone ever do promotional fans?
by SouthTex- Replies
- 7
- Views
- 110
-
09-23-2011, 08:55 AM
Thread: Free Estimates
by SouthTex- Replies
- 6
- Views
- 137
-
09-20-2011, 01:28 PM
Thread: Slow Summer Here
by SouthTex- Replies
- 24
- Views
- 1,398
Guys all getting their hours, but the residential...
Guys all getting their hours, but the residential change out market is slow. Figured there were two reasons. Last year we had the $1500.00 tax credit and alot of units got changed out, and people...
-
09-20-2011, 08:53 AM
- Replies
- 52
- Views
- 1,774
They still make a good product. As far as...
They still make a good product. As far as inventory they all have their issues. I've waited as much as six months for a Carrier condenser coil for a package unit that was a week old. Locally we...
-
09-12-2011, 10:51 AM
- Replies
- 32
- Views
- 1,770
Most contractors do not carry the off brands...
Most contractors do not carry the off brands because in the overall cost of the job there is normally not a huge difference in equipment cost. I would venture to say there is less than 5% difference...
-
09-10-2011, 01:06 PM
Thread: Light Commercial Automation System?
by SouthTex- Replies
- 12
- Views
- 1,106
Take a look at Auto Zone by Wattmaster, have used...
Take a look at Auto Zone by Wattmaster, have used it for years and has proven to be extremely reliable and user friendly. With a basic system you can do everything you have described. In addition...
-
08-30-2011, 08:41 AM
Thread: Sheave replacement
by SouthTex- Replies
- 2
- Views
- 1,166
pull the entire blower assembly out and change it...
pull the entire blower assembly out and change it outside the unit,
-
08-14-2011, 08:00 AM
Thread: coleman coil
by SouthTex- Replies
- 23
- Views
- 2,354
had one one time installers installed txv didn't...
had one one time installers installed txv didn't take out the flow rater, low suction poor split unit was charged by subcooling to specs
-
08-11-2011, 02:18 PM
Thread: Data Loggers
by SouthTex- Replies
- 5
- Views
- 602
Ditto- we use them for temps/humidity, another...
Ditto- we use them for temps/humidity, another set for volts/amps have had them for 6 or 7 years still working
-
08-11-2011, 01:51 PM
Thread: New HVAC student
by SouthTex- Replies
- 23
- Views
- 1,842
Ladders are used every day by most of our people,...
Ladders are used every day by most of our people, commerical guys are on roofs alot.
-
08-07-2011, 07:24 AM
- Replies
- 24
- Views
- 2,161
Look into a damper system, increasing the size of...
Look into a damper system, increasing the size of the unit or duct will not solve the problem as the unit will follow the commands of the thermostat which I assume is located downstairs. Remember...