  3. Replies
    4
    Views
    749

    This is a good manual for checking low oil...

    This is a good manual for checking low oil pressure problems. Hope it helps.
  4. Replies
    12
    Views
    1,624

    Sounds like low load. Is it possible your getting...

    Sounds like low load. Is it possible your getting some carryover from the supply air back to the return?
  5. Replies
    12
    Views
    1,624

    What is the alarm? What are the pressures and...

    What is the alarm? What are the pressures and temperratures. You need to update your profile.
  6. Thread: Trane pcu

    by Phisher
    Replies
    2
    Views
    853

    You won't get any help here with a Sept. 2011...

    You won't get any help here with a Sept. 2011 join date, 1 post and nothing in your profile. Sorry but we have to protect the integrity of our business.
  7. Replies
    8
    Views
    504

    Sounds like you have the Voyager Microcontrols...

    Sounds like you have the Voyager Microcontrols book. That is a must have book for any tech to have on his truck. I recommend anyone who works on Voyagers to pick one up at your local Trane parts...
  8. Replies
    4
    Views
    534

    Trane had a problem with tandem scrolls loosing...

    Trane had a problem with tandem scrolls loosing oil in the 1st compressor. They installed a washer type orifice in the downstream compressor to force more oil to return into the first compressor. You...
  9. Replies
    30
    Views
    3,716

    Make sure all of the condenser fans are rotating...

    Make sure all of the condenser fans are rotating the right direction. You will bypass a lot of the coil if one of the fans is running backward. There should be a noticeable temperature drop across...
  10. Replies
    25
    Views
    1,536

    Good point klove

    Good point klove
  11. Replies
    20
    Views
    2,111

    Ever see what comes off of a lake on a cool...

    Ever see what comes off of a lake on a cool morning? The air temperature needs to be 2 degrees warmer.

    TJP you need to have a good understanding of the equipment as a whole or you will never get...
  12. Replies
    25
    Views
    1,536

    Hmm Never thought about pushing in the contactor...

    Hmm Never thought about pushing in the contactor to reset a safety. Not sure how that resets the control circuit.
  13. Replies
    25
    Views
    1,536

    Sounds like it could be something like the anti...

    Sounds like it could be something like the anti short cycle timer part of the thermostat or control circuit not resetting after the unit satisfies. Does the contactor have auxiliary switches? You...
  14. Replies
    21
    Views
    2,543

    I've used a hammer to break em loose. Reversing...

    I've used a hammer to break em loose. Reversing rotation for a couple seconds will also break em loose. This should only be done to get the customer out of a jam until the new compressor can be...
  15. Replies
    3
    Views
    1,500

    I've had problems in the past with the same...

    I've had problems in the past with the same controler. I found that if you put a time delay accross M1 and M2 on startup the problem goes away. A 10 second time delay should work.
  16. Replies
    13
    Views
    1,299

    Good luck to ya... Hope all goes well.

    Good luck to ya... Hope all goes well.
  17. Replies
    8
    Views
    1,039

    Those readings indicate low water flow. You...

    Those readings indicate low water flow. You eather have a restriction or the lines are too small. Do the lines reduce in size coming out of the heatpump?
  18. Replies
    13
    Views
    1,299

    Well you wouldn't have to worry about moister in...

    Well you wouldn't have to worry about moister in the system freezing at the TXV.:grin2: Really though 1-1/2 ton unit? Replace it and be done with it.
  19. Replies
    8
    Views
    1,039

    The water lines were sized for a 1/2 ton unit and...

    The water lines were sized for a 1/2 ton unit and a 1-1/4 ton was installed. The water lines are probably under sized, restricting flow thru the unit. Check the manufacturers IOM for flow rates and...
  20. Replies
    17
    Views
    2,474

    Mikeymoe: Now I know someone from Brooklyn

    Mikeymoe: Now I know someone from Brooklyn
  21. Replies
    4
    Views
    990

    make sure you're using a 500 volt megger to check...

    make sure you're using a 500 volt megger to check for a grounded compressor. Trane started adding sump heaters on there scroll compressors due to compressor failures. You need to add a heater on the...
  22. Thread: Trane Voyager

    by Phisher
    Replies
    8
    Views
    1,805

    You can't get a good gas pressure reading with...

    You can't get a good gas pressure reading with the inducer fan off. Did you check for voltage at the inducer motor when the gas valve energizes?
  23. Replies
    17
    Views
    2,474

    Your unit came with no options (digit 10 on page...

    Your unit came with no options (digit 10 on page 23). The damper is for minimum outside air not economizer operation. There is a wiring diagram in the back of the manual. Economizer control can be...
  24. Replies
    17
    Views
    2,474

    The economizer is an option that your unit may...

    The economizer is an option that your unit may not have come with. Can you recheck the serial no. and repost. The wiring diagram should be on the control door.
  25. Replies
    22
    Views
    2,429

    The guys on this site didn't learn Trane controls...

    The guys on this site didn't learn Trane controls overnight. It takes a lot of studying manuals on your own time and taking classes. Don't blame the manual or the fact that you can't get in touch...