05-09-2013, 06:43 AM
Thread: Need some assistance
by Dowadudda- Replies
- 5
- Views
- 202
Need some assistance
I am in the final stages of completion of updating a control system at a site which has refrigeration, hvac VAV, CAV, Lighting ect. This is a supermarket with rack refrigeration. It's more than a...
-
04-29-2013, 08:10 PM
Thread: Serial Server
by Dowadudda- Replies
- 6
- Views
- 181
Serial Server
Anyone have much luck doing rs232 to ip with a serial server. I have an old school rs232 comm for two plc controllers I plan to connect to a lan.
-
04-08-2013, 05:38 AM
- Replies
- 32
- Views
- 1,080
The points made are about knowledge no? Being...
The points made are about knowledge no? Being prepared and understanding what it is and how it can react. I am not trying to be arrogant, but I mean if your prepared for the job, and the new...
-
04-06-2013, 06:31 PM
- Replies
- 32
- Views
- 1,080
I will see one with in the year. Looking forward...
I will see one with in the year. Looking forward to it. I have heard some horror stories, but I think the stories were dramatized only because it's CO'2. What start up isn't a crazy few weeks. ...
-
03-24-2013, 10:28 PM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
I am excited to having a steady diet of all kinds...
I am excited to having a steady diet of all kinds of ems work again and before too long I will have it in my brain again.
JP, if you recall me telling you, this was the same store where someone... -
03-24-2013, 10:22 PM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
I was a little too much in a hurry, should have...
I was a little too much in a hurry, should have stayed the day I was there and check it all very fine tooth comb but did not.
I did not just walk away, I was poking around at stuff but you know.... -
03-24-2013, 10:17 PM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
I caught that one on this controller. You know...
I caught that one on this controller. You know as you step up the DB, which btw thanks to you I learned that JP. Any ways, it when you go from whatever to VR2.081, it tells you, that. Tells you to...
-
03-24-2013, 10:00 PM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
For some reason, pulling the old DB, running it...
For some reason, pulling the old DB, running it through firmware upgrade, then uploading it to the new controller, it swapped 4 esr circuits. No idea why. The old DB same as new, but Markettechs...
-
03-24-2013, 09:52 PM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
That was me. Oh well.
That was me. Oh well.
-
I have a ton to do. It's the database swap over,...
I have a ton to do. It's the database swap over, where you have to suck the old database, and key in by hand over to the new platform, after you do a few, it just gets very old very quick. It...
-
03-24-2013, 09:37 AM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
Oh god. Seen it happen myself. Sparkticians got...
Oh god. Seen it happen myself. Sparkticians got the job to run and land wire, by whinning about why a reefer guy was originally intended to do it. Big ole mess on that. But they eventually got...
-
03-24-2013, 09:15 AM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
JP, bear in mind buddy, I now again work for an...
JP, bear in mind buddy, I now again work for an HP Dealer. I am just practicing my lines.
HP is GGGRRRREAT. ;) -
Oh God. Thanks for memory lane. And the...
Oh God. Thanks for memory lane. And the refresher. I have quite a bit of work ahead of me cutting over these guys. Quite a few.
It's the plugging the existing database to the new I am not... -
03-24-2013, 09:05 AM
Thread: rack supermarket system question
by Dowadudda- Replies
- 10
- Views
- 798
I had a cpc engineer sales guy tell me one time...
I had a cpc engineer sales guy tell me one time that you could put any number in the capacity of a compressor in the suction application, as long as the number represented in some fashion the size of...
-
03-24-2013, 08:58 AM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
it's not that bad. start up guy should be...
it's not that bad. start up guy should be getting that stuff tight. I actually like the set up.
-
03-23-2013, 08:15 PM
Thread: r22 conversions
by Dowadudda- Replies
- 45
- Views
- 1,351
Jp, I was just asking cause the ones I have been...
Jp, I was just asking cause the ones I have been involved with, a total of 3 in my career, not many, 1 in TX, 2 in MI, we did change them.
Its gotta depend on the valve manufacturer. Gotta. I... -
03-23-2013, 07:31 PM
Thread: r22 conversions
by Dowadudda- Replies
- 45
- Views
- 1,351
JP, so ball valves and what not, your customers...
JP, so ball valves and what not, your customers are not requiring it?
-
03-23-2013, 03:16 PM
Thread: r22 conversions
by Dowadudda- Replies
- 45
- Views
- 1,351
Like Matt just said Ice. Customer is requiring...
Like Matt just said Ice. Customer is requiring ball valves and stuff. I did not understand the swelling and just read more about that, your right on.
Its a pretty big job in short time frame... -
03-23-2013, 10:04 AM
Thread: r22 conversions
by Dowadudda- Replies
- 45
- Views
- 1,351
That's what I have been apart of doing. Oil done...
That's what I have been apart of doing. Oil done ahead of time. And it takes 3 changes to get to 98% I believe they want to see. I might have that % wrong. U have to use a refractometer to check...
-
03-23-2013, 08:19 AM
Thread: r22 conversions
by Dowadudda- Replies
- 45
- Views
- 1,351
I dunno. Thats a pretty optimistic look.
I dunno. Thats a pretty optimistic look.
-
03-23-2013, 08:09 AM
Thread: Hussman RL-5 cases
by Dowadudda- Replies
- 63
- Views
- 2,056
your first sentence is untrue. the second...
your first sentence is untrue. the second sentence was about pacifying you.
the second statement is accurate. I talk a great game. -
03-23-2013, 07:48 AM
Thread: Vertical pie display cooler
by Dowadudda- Replies
- 8
- Views
- 425
what kind of start? CSIR or CSCR? PSC or RSIR? ...
what kind of start? CSIR or CSCR? PSC or RSIR? The later two start configs would perhaps be why you would possibly need to look at equalization pressures causing you an issue. You adjusted the...
-
03-23-2013, 07:24 AM
Thread: real head scratcher
by Dowadudda- Replies
- 18
- Views
- 1,151
325 is 123ish Saturated. You got 115ish liquid...
325 is 123ish Saturated. You got 115ish liquid line temp. So you have subcooling, but flashing through the glass. I would be curious the delta T across the condenser and the TD. I think this...
-
03-23-2013, 07:07 AM
Thread: r22 conversions
by Dowadudda- Replies
- 45
- Views
- 1,351
This conversion storm is about ready to launch...
This conversion storm is about ready to launch here across the country with in the next 18 months. Great time to be in the refrigeration trade. There is gonna be so much work it's just incredible. ...
-
03-23-2013, 06:58 AM
Thread: Temperature rise on defrost
by Dowadudda- Replies
- 12
- Views
- 457
KE2 Therm taking the refrigeration world by...
KE2 Therm taking the refrigeration world by storm. I will be seeing mucho grande of this shortly and need to get studied up.