Search:

Type: Posts; User: bacciagalupe

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    11
    Views
    449

    ditto easy fiix have to replace the entire glass

    ditto easy fiix have to replace the entire glass
  2. Replies
    17
    Views
    829

    on your 5 th post you said they checked out fine ?

    on your 5 th post you said they checked out fine ?
  3. Replies
    4
    Views
    253

    dual voltage unit ? 208 /230 volt unit .3 wire...

    dual voltage unit ? 208 /230 volt unit .3 wire with a neutral leg ?
  4. Replies
    8
    Views
    628

    :deadhorse:

    :deadhorse:
  5. Replies
    7
    Views
    625

    :cheers:

    :cheers:
  6. interested in moving to north or south Carolina

    i do refrigeration work. not sure what part i want to move to any suggestions. and any good companies out there ? i have been in the field for 17 plus years.
  7. Replies
    13
    Views
    5,545

    check the voltage at the water inlet valve :gah:

    check the voltage at the water inlet valve :gah:
  8. Replies
    13
    Views
    5,545

    i have seen the voltage drop out. and the water...

    i have seen the voltage drop out. and the water valve keep running water for a few seconds and over filling the sump area. and you pull the hose and see no water .your first thought would be the...
  9. Replies
    16
    Views
    1,232

    11 1/4 inches lol

    11 1/4 inches lol
  10. Replies
    14
    Views
    1,005

    the a/c vent is a no no above an open air case

    the a/c vent is a no no above an open air case
  11. when did you ever see a chest freezer with...

    when did you ever see a chest freezer with defrost just saying ?
  12. and i don't blow off crap .

    and i don't blow off crap .
  13. Replies
    17
    Views
    1,322

    chipping the ice off will help the plate :whistle:

    chipping the ice off will help the plate :whistle:
  14. Replies
    12
    Views
    737

    use the tips of needle nose pliers .i believe...

    use the tips of needle nose pliers .i believe some service wrenches had them on them ?
  15. Replies
    11
    Views
    734

    who is paying for the repair you or the customer...

    who is paying for the repair you or the customer ? now add the prices of the oil changes ? how much more is it ?
  16. Replies
    11
    Views
    734

    just use 408 and be done with it no oil change...

    just use 408 and be done with it
    no oil change needed
  17. Replies
    28
    Views
    1,453

    united refrigeration sells .036 cap tube. # tc36...

    united refrigeration sells .036 cap tube. # tc36 . i would have went with the bc2 .040 . .031 seems too small
  18. Replies
    4
    Views
    423

    It will take more than a few days to thaw. i have...

    It will take more than a few days to thaw. i have seen box's down a week and there still was ice when i took apart a box to relocate it . might want to put a few heaters in it to help thaw
  19. Replies
    5
    Views
    492

    low charge

    low charge
  20. Replies
    7
    Views
    514

    use mp 66

    use mp 66
  21. Replies
    87
    Views
    4,862

    sensing tube tool

    the guy that i work with has and old one that ranco used to sell or give away .i have been looking for one my self i use a small hose clamp and attach the end to a Phillips screw driver then wrap...
  22. Replies
    4
    Views
    517

    what ever i use out of my truck stock .i keep the...

    what ever i use out of my truck stock .i keep the box top then when i go to the supply house . i restock what ever i used .
  23. Replies
    23
    Views
    1,788

    what kind of freezer M# S# ? i have seen the door...

    what kind of freezer M# S# ? i have seen the door pins get wet when unit in defrost . i believe it was a continentail . the drain line was pitched back making water drip on to box .not in pan
  24. Replies
    10
    Views
    1,142

    that's what i was taught also

    that's what i was taught also
  25. Thread: How come?

    by bacciagalupe
    Replies
    27
    Views
    3,788

    they didn't pay the bill

    they didn't pay the bill
  26. Replies
    30
    Views
    2,762

    just do what most hacks do . leave it hooked up...

    just do what most hacks do . leave it hooked up to the unit and install another and use an acess tee on the service port . and be done with it or pinch off the line cut it free and braze the new one...
  27. the hammer kisses are the dopes knocking the ice...

    the hammer kisses are the dopes knocking the ice off the strips i would order new strips , heater , and be done with it they are sometimes hard to reinstall when they are banged up
  28. Replies
    16
    Views
    1,247

    i use nu brite for condenser coils. but you need...

    i use nu brite for condenser coils. but you need to rinse it off well . and cal clean hd for the evap coil's
  29. looking for a refrigeration job in ct.

    looking to get a refrigeration job in ct.i have 16 years in the field now need to move on before they close the doors on me. anyone hiring in ct area ?
  30. Thread: Amp meter

    by bacciagalupe
    Replies
    57
    Views
    6,239

    I use a fluke 27 love the meter . and i still...

    I use a fluke 27 love the meter . and i still have the smaller amp probe that is no longer sold .the newer ones are all big
  31. Replies
    0
    Views
    634

    Solaronics Radiant Tube Heater

    I installed a Solaronics Radiant Tube Heater and for some reason the Ignition Detection control keeps failing . every three years is this normal for these heaters?solaronics changed the original...
  32. Replies
    3,469
    Views
    149,060

    Because I Can . How would i go Hunting ? How...

    Because I Can . How would i go Hunting ? How would i go Target Shooting ? How would i stop the ******* that is robbing me at gun point ?
  33. Replies
    73
    Views
    13,063

    go to work in a supply house . crawling around on...

    go to work in a supply house . crawling around on your knees in a cluttered attic or basement isn't that fun. and when the temps reach 100 it gets even harder . Just Saying
  34. Replies
    16
    Views
    3,026

    if its flaking get a new one sounds unsafe to me...

    if its flaking get a new one sounds unsafe to me . OSHA also wants to see the labels or they will comdem them .
  35. how can you weigh in the charge on a remoted cap...

    how can you weigh in the charge on a remoted cap tube system ? the unit needs a expansion valve and a receiver and cold controls to work properly
  36. Replies
    9
    Views
    1,561

    here we go with the hot shot . hot shot sucks ....

    here we go with the hot shot . hot shot sucks . and it has r22 in it anyway . just use r22 and be done with it. or have him get a new icemaker
  37. Replies
    20
    Views
    3,923

    :whistle:

    :whistle:
  38. Replies
    27
    Views
    2,863

    i see this al the time . all they needed was a...

    i see this al the time . all they needed was a zip tie
  39. looks like a subway i/m the also get pretty...

    looks like a subway i/m the also get pretty slimed up
  40. Thread: hoshi

    by bacciagalupe
    Replies
    24
    Views
    2,153

    Hoshizaki tech service # 1- 800-233-1940 check...

    Hoshizaki tech service # 1- 800-233-1940 check the plates ? if its making ice on top and bottom and not middle / i suspect tubing seprating from the plates seen it happen alot and they kinda run ok...
  41. Replies
    18
    Views
    1,475

    isnt the sight glass usless with out a reciever....

    isnt the sight glass usless with out a reciever. need to contact master built and get proper name plate charge for that box . and weigh it in . and make shure there is not a cpr valve on that system...
  42. Replies
    18
    Views
    1,475

    did you weigh in the charge ? does the unit have...

    did you weigh in the charge ? does the unit have a reciever on it ?
  43. Thread: hoshi

    by bacciagalupe
    Replies
    24
    Views
    2,153

    make shure you dont have plate sepration from the...

    make shure you dont have plate sepration from the tubing
  44. Thread: hoshi

    by bacciagalupe
    Replies
    24
    Views
    2,153

    record perssures through out a cycle sounds like...

    record perssures through out a cycle sounds like a hot gas valve problem . what type of erra codes are you getting .
  45. Thread: hoshi

    by bacciagalupe
    Replies
    24
    Views
    2,153

    make shure the plates are clean.

    make shure the plates are clean.
  46. Thread: Wendy's

    by bacciagalupe
    Replies
    49
    Views
    11,733

    plan b burgers are very good

    plan b burgers are very good
  47. Replies
    56
    Views
    4,215

    tape a plastic cap over the relief valve . we had...

    tape a plastic cap over the relief valve . we had a rack problem simler to this and we found out that the relief valve was blowing off at night . and we traced it back to a faulty hold back valve
  48. i used threaded rod from the top ribs of the roof...

    i used threaded rod from the top ribs of the roof to the top of the shelfs . they never moved .and to this day are tight . a bit difficult to get the nut on the rod above the rib but worth it.been...
  49. Thread: Hot Shot

    by bacciagalupe
    Replies
    13
    Views
    7,158

    i use 409 or mp39 for a replacement for r 12 ...

    i use 409 or mp39 for a replacement for r 12 never use 134 as a replacement for r12
  50. whats a henway LOL :grin2:

    whats a henway LOL
    :grin2:
Results 1 to 50 of 164
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image