    Thanks for all the information. I still haven't...

    Thanks for all the information. I still haven't done anything. If the "special pricing" is cheap enough I will probably try one. However, it bothers me too. Guys with no license can go the...
  2. Replies
    32
    Views
    1,718

    Goodman Equipment ?

    I usually install Ruud or ICP equipment. The local Goodman dist. has signed me up for special pricing.(?) I use to install Goodman equipment, but had too many issues and had to get off it. I was...
  3. Replies
    24
    Views
    1,221

    I have used the saws all several times. I cut...

    I have used the saws all several times. I cut the three top tubes on the valve and used a tubing cutter on the bottom making sure no cuttings get into the system. Then I heated the tubing ends to...
  4. I installed a "bunch" of Nordyne equipment...

    I installed a "bunch" of Nordyne equipment (Tappan) about three years ago. I had too many leakers. I have 5 coils to replace right now. I bet I am running about 70% on evaporator coils, which...
  5. Thread: ADP Coils

    by Becool
    Replies
    4
    Views
    474

    I have installed several ADP coils recently and...

    I have installed several ADP coils recently and have had no issues. I have another one to do tomorrow.... I sure hope they don't bite me in the but.. I have had a "bunch" of Nordyne coils leak a...
  6. Replies
    12
    Views
    497

    It worked fine in a/c mode which told me the...

    It worked fine in a/c mode which told me the sensing bulb was good. I pumped system down and then purged both sides with N2. N2 flowed freely in the high side and out the low at service valve and...
  7. Replies
    12
    Views
    497

    After ruling out the indoor TXV, I checked the...

    After ruling out the indoor TXV, I checked the dryer. I blew nitrogen thru the loop both ways and there was no blockage.
  8. Replies
    12
    Views
    497

    In Hp mode, it is pumping the 3/8 line down to 10...

    In Hp mode, it is pumping the 3/8 line down to 10 lb and the vapor line goes the other way. It is the piston as the services access is down stream from the piston. The piston in Hp mode shifts...
  9. Replies
    12
    Views
    497

    This piston is in front of the high side service...

    This piston is in front of the high side service valve on the out side of the condenser. When I try to remove it, it seems like there is a lip in the tube that prevents it from slipping out. I...
  10. Replies
    12
    Views
    497

    Heil 3Ton Dry Hp with piston sticking

    I installed a Dry (Nitrogen) 3 Ton Hp Condensing unit two years ago. It has been working fine until a few weeks ago. The piston in the Hp is locking up when the unit is in Hp mode. I can see it...
  11. Replies
    34
    Views
    1,414

    The shipping box stated that the Compressor is a...

    The shipping box stated that the Compressor is a FSP (Factory Specification Part) product of Whirlpool corporation made in Brazil.
    I did not see anything about product of USA.
  12. Replies
    34
    Views
    1,414

    I finally broke down and bought a new compressor....

    I finally broke down and bought a new compressor. It came in Thursday, but did not have time to install it until this morning. I had not changed out a refrigerator compressor before, but it was...
  13. Replies
    34
    Views
    1,414

    I read Consumer Reports and Whirlpool was rated...

    I read Consumer Reports and Whirlpool was rated at the top of the list. The last Frig. I bought in 1971 and it is now running in a rental property and this one is only about 2 years old and is...
  14. Replies
    34
    Views
    1,414

    Good idea! I will do that tomorrow. thanks

    Good idea! I will do that tomorrow. thanks
  15. Replies
    34
    Views
    1,414

    Just go in ... The liquid line is hot and that...

    Just go in ... The liquid line is hot and that is what bothers me and I know the suction pressure is too high. It might be bye passing into the suction side? I have had a/c units do it. As far as...
  16. Replies
    34
    Views
    1,414

    It is 134a....

    It is 134a....
  17. Replies
    34
    Views
    1,414

    I mounted a saddle clamp on the process stub and...

    I mounted a saddle clamp on the process stub and took a reading with my gauges.
  18. Replies
    34
    Views
    1,414

    Domestic refrigerator not cooling..

    I do mostly residential A/C (installation and repair), so I need another opinion . My 2 year old Whirlpool frig. is not cooling properly. Freezer drawer on bottom and frig. on top. Info: Unit is...
  19. Thread: AHRI Directory

    by Becool
    Replies
    8
    Views
    632

    I generally go to the Manufacture's website and...

    I generally go to the Manufacture's website and get the Ahri number for the equipment and just enter it in the directory. It is much easier...
  20. Thread: INSIDER....

    by Becool
    Replies
    4
    Views
    426

    We are installing an Intertherm straight elect....

    We are installing an Intertherm straight elect. AH with an A-Coil and Ruud a/c Condensing unit. Ice and snow shut us down, but we did get the HO some heat. The a/c will come when the weather gets...
  21. Thread: INSIDER....

    by Becool
    Replies
    4
    Views
    426

    Thanks for the advice. The unit came out of the...

    Thanks for the advice. The unit came out of the closet just like they all do. This one was just much heavier a bit larger. Thank goodness for two "wheelers". Once we got the truck under it, we...
  22. Thread: INSIDER....

    by Becool
    Replies
    4
    Views
    426

    INSIDER....

    I have to pull an Insider(self contained) heat pump mobile home unit tomorrow. I have not seen one before never mind removing one. If anyone has experience with these units, all suggestions would...
  23. Replies
    4
    Views
    457

    I do not know of a reg. I usually start at 4 in....

    I do not know of a reg. I usually start at 4 in. off an exterior wall and make sure you do not get one in a walk -way (door).
  24. Replies
    6
    Views
    717

    I typically used a camera. I bought it last year...

    I typically used a camera. I bought it last year and it has paid for itself. It saves a lot of time and eliminates the ques work.
  25. Thread: EMC End Bells ?

    by Becool
    Replies
    5
    Views
    792

    EMC End Bells ?

    I have found several ECM evaporator motors that have bad end bells recently. They are out or warranty and I was wondering if anyone has had any luck trying to rebuild these things? Usually it is a...