  1. Replies
    7
    Views
    803

    Need to same code for older Distech Free Prog...

    Need to same code for older Distech Free Prog controller. I tried using nvi17 without success.
  2. Network 8000 Signal Engineering Units Display Issue

    Signal version 4.4.1, Windows 95 machine. Recently the engineering units displayed for a Microflo II Remote Setpoint Enable point (RSPEN) started displaying "Link Type (1) or Link Type (0)". ...
  3. Replies
    1
    Views
    402

    As follow-up, found that StatusRmTmpActSpt was =...

    As follow-up, found that StatusRmTmpActSpt was = to nciSetpoints occupied heat value, even though StatusOcc read unoccupied.

    nciSetpoint valves appeared to be in correct order, i.e. Unoccupied...
  4. Replies
    1
    Views
    402

    Honeywell T7300 unoccupied issue

    Multiple T7300 tstats connected to Tridium R2 JACE (version 527). On some tstats StatusOcc shows unoccupied, yet stat appears to be controlling around occupied heat setpoint, based on review of...
  5. Replies
    1
    Views
    288

    AX Enum Writable object - override time

    Looking for enum writable object in AX that would allow for override ending time to be set as time and date rather than hours. Thanks.
  6. Replies
    3
    Views
    1,858

    BC Jetronic

    Any info out there available for these? Thanks.
  7. Replies
    17
    Views
    1,758

    See this post from 2008: ...

    See this post from 2008:

    http://hvac-talk.com/vbb/showthread.php?t=185126&highlight=trane+driver


    As dapper said, Trane used the 18/2 "purple" shielded cable early in LON; I think I have seen...
  8. Thread: Dirty group

    by ddcctrl
    Replies
    8
    Views
    654

    Check LonUtilitiesManager-Reports-Verify. This...

    Check LonUtilitiesManager-Reports-Verify. This may reveal an issue with one controller. Also if you have controllers that are offline you may not be able to clear up the dirty groups.
  9. Replies
    1
    Views
    607

    Liebert Sitelink panel

    From Liebert's website, in the SiteLink-E installation document:

    "The Liebert SiteLink-E communicates using BACnet and/or third-party protocols, and can connect to a variety of port types at...
  10. Replies
    2
    Views
    685

    AX will run on Vista Home Premium with no...

    AX will run on Vista Home Premium with no problems. If you are using the computer for engineering R2 will work fine. If you trying to run a station on the computer it will probably not work for R2...
  11. Replies
    10
    Views
    2,809

    Hello Krac: Can you contact me concerning what...

    Hello Krac:

    Can you contact me concerning what your solution was for this? I have similar opportunity. Please see email and IM info in profile. Thanks.
  12. Had similar problem even with the latest BACnet...

    Had similar problem even with the latest BACnet JAR file. I added the following in the bacnet.properties file and all has been well since (as far as I know):

    pollHeartbeatCheck=true # to...
  13. Replies
    23
    Views
    1,326

    I have seen this issue with an AX to R2 BACnet...

    I have seen this issue with an AX to R2 BACnet integration, with setpoint control. The server was R2, sending setpoint info to AX JACE. The BACnet AVP point linked to a Numeric Writable at first...
  14. Replies
    4
    Views
    741

    I have bought and sold controllers on ebay and...

    I have bought and sold controllers on ebay and have had good success. You can also find Belimo stuff on there as well.
  15. Replies
    6
    Views
    1,233

    I second dapper on this one.

    I second dapper on this one.
  16. Replies
    26
    Views
    3,474

    You could team up with a Tridium Vykon System...

    You could team up with a Tridium Vykon System Integrator (http://www.tridium.com/cs/purchase_products/north_america) to provide you with the AX hardware. You should be able to find someone willing...
  17. Thread: Career Advice

    by ddcctrl
    Replies
    8
    Views
    1,158

    Have you considered starting your own controls...

    Have you considered starting your own controls company? Or, if you are in Michigan you might consider touching base with the following company: http://www.abcsys.net/. I have had correspondance...
  18. Replies
    11
    Views
    747

    We have used a custom program object in AX 3.1.30...

    We have used a custom program object in AX 3.1.30 that does most of what you want to do. Email if interested.
  19. Replies
    12
    Views
    1,329

    What type of Network 8000 controllers do you have?

    What type of Network 8000 controllers do you have?
  20. Thread: Invensys

    by ddcctrl
    Replies
    1
    Views
    688

    Signal is the front-end software. Is the system...

    Signal is the front-end software. Is the system Nerwork 8000 (Barber Colman) or DMS (Robertshaw). Signal is connected serially to the GCM (if Network 8000). What type of field controllers do you...
  21. Replies
    9
    Views
    1,807

    I took a look at the cut sheet, and I see now...

    I took a look at the cut sheet, and I see now that these are for the Microzone or Microflo I series controllers. The companies' name has changed (as you may know) from Barber Colman, to Siebe, to...
  22. Replies
    9
    Views
    1,807

    Are you perhaps talking about the TS-90230...

    Are you perhaps talking about the TS-90230 sensor? If you are, you can order an ACI sensor, ACI/10K-AN-RO, and add an 11K ohm, 1/4 watt resistor across the sensor terminals. This sensor also has a...
  23. Replies
    3
    Views
    628

    You may be using an early version of the PEM...

    You may be using an early version of the PEM software. PEM's came out circa 1992 as an application specifc controller. PSI was used to download the application, and you could only edit values. ...
  24. Replies
    10
    Views
    1,095

    I would guess the COS alarm is for a pump. The...

    I would guess the COS alarm is for a pump. The OFF R means the condition has returned to normal. The COS block usually compares the equipment status with the equipment command. If the alarm says...
  25. Replies
    10
    Views
    1,095

    ALARM is numeric alarm (temperature, humidity,...

    ALARM is numeric alarm (temperature, humidity, pressure, etc.). It alarms based on alarm value and return from alarm value set-up in the GCM Blocks (as incontrol said you would have to look at the...