Search:

Type: Posts; User: fridg

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. I have 2 leak detectors a cps eliminator 3000 & a...

    I have 2 leak detectors a cps eliminator 3000 & a javac D-Tek select ,,, always has the javac found the smallest leaks imaginable & including leaks in ceiling cavities that the air conditioning...
  2. Thread: Truck stocks app

    by fridg
    Replies
    4
    Views
    400

    Hey guys , think this is going to work really...

    Hey guys , think this is going to work really well.
    Link is below , pass it on.



    Stock Control
    List your items, sort them into categories and associate them with places of storage....
  3. Thread: Truck stocks app

    by fridg
    Replies
    4
    Views
    400

    Truck stocks app

    Hey guys , getting sick of remembering what my stocks are like in my truck , any good (free) mobile apps out there for inventory levels ?
  4. Replies
    2
    Views
    757

    Could be a safety , like evaporator probe holding...

    Could be a safety , like evaporator probe holding compressor out.

    Some manufactures use this as a freeze up safety if the evap coil temp gets below say -11deg C

    More info may be of some help.
  5. Covers OH&S also. But unless there is no stock...

    Covers OH&S also.

    But unless there is no stock , I think there will always be window shoppers , or people that just like to inconvenience us as much as possible.
  6. Replies
    35
    Views
    5,247

    A few of our guys have traded the traditionnal...

    A few of our guys have traded the traditionnal oxy act setup for these beauties , I have been told "you do use 2 bottles of Oxygen to 1 bottle of Mapp but well worth it" I am on my way to get myself...
  7. Replies
    11
    Views
    1,829

    Some useful info for another time , after being...

    Some useful info for another time , after being in design of cabinets & cases of the cap tube variety , most only run at 1K subcooling.

    Also receiver should never be installed on cap tube , but...
  8. Replies
    8
    Views
    1,115

    Have seen this on small cabinet freezers , from...

    Have seen this on small cabinet freezers , from manufacture new solenoid hammering hot gas to coil , spring tension on danfoss valve incorrect , hence not seating correct.
  9. Replies
    16
    Views
    2,050

    We have just had this phase ourselves ,...

    We have just had this phase ourselves , Refrigerant R404A, widely used in industrial and supermarket refrigeration, will increase from $92.88 per kilo to $377.71 per kilo following the implementation...
  10. Replies
    6
    Views
    1,822

    Ahhh , that is going straight to the library...

    Ahhh , that is going straight to the library :spitball:
  11. Replies
    7
    Views
    545

    Totally agree , a compressor efficiency test will...

    Totally agree , a compressor efficiency test will tell you with 100% accuracy if it is doing the job it has been designed to do.
  12. Replies
    15
    Views
    1,453

    The manufacturer will tell you that a cap tube...

    The manufacturer will tell you that a cap tube system is critically charged , they are to some extent but you can cut off up to 200mm on some and be confident that it will still run to design...
  13. Replies
    11
    Views
    954

    Why not have it on auto mode with a timer in the...

    Why not have it on auto mode with a timer in the outdoor unit to start + stop ?
  14. Replies
    17
    Views
    2,751

    Manitowoc requires you to use one of these so as...

    Manitowoc requires you to use one of these so as to not interfere with the charge , they do work.

    http://t1.gstatic.com/images?q=tbn:ANd9GcSH8Go3XP9KAZlxVfgijOIbYz0MwdORsa7UNJcHL3Qiqvvxf8zo2P2P1OCK
  15. Thread: Simulator

    by fridg
    Replies
    4
    Views
    819

    Innotech does a program that lets you build a...

    Innotech does a program that lets you build a control circut then test for functionality.

    Innotech Software
  16. Replies
    227
    Views
    45,500

    I only see one lock-out device in all these bags....

    I only see one lock-out device in all these bags.

    Is it mandatory to lock-out & isolate the supply like it is here in OZ. :.02:
  17. Replies
    9
    Views
    979

    The Accumulator is primarily there for off cycle...

    The Accumulator is primarily there for off cycle safety.

    Refrigerant is going to migrate to the coldest place in an off cycle , this is the evap , when the system calls for cooling again the...
  18. Replies
    111
    Views
    5,777

    I beg to differ with the price shown in Australia...

    I beg to differ with the price shown in Australia $3.84 Gallon

    That equates to $1.01 Litre , if that is true this would be the cheapest fuel in OZ , the station serving this would be one popular...
  19. Replies
    111
    Views
    5,777

    "Unleaded fuels carry a RON (Research Octane...

    "Unleaded fuels carry a RON (Research Octane Number) rating. Put simply, RON determines petrol's 'anti-knock' quality or resistance to pre-ignition; or if you want to put in another way, the Octane...
  20. Replies
    111
    Views
    5,777

    Self service stations here are $1.26 L for...

    Self service stations here are $1.26 L for Regular Unleaded (91 RON) & $1.36 L for Premium Unleaded (98 RON)

    But if you you go to a drive through with service provided the price jump is absurd. ...
  21. Replies
    10
    Views
    2,168

    If the capacity of the system was based on 134A...

    If the capacity of the system was based on 134A and you are Retro-fitting to 404A you will need to have a good look at the system in total , the load & thermodynamic properties of 404A.

    Do some...
  22. Replies
    4
    Views
    728

    I agree with using the OEM , but sometimes it...

    I agree with using the OEM , but sometimes it takes months to recieve parts from the U.S , and not mention Manitowoc's price mark up on spare parts.

    From the information i have recieved , the...
  23. Thread: Corned Beef

    by fridg
    Replies
    33
    Views
    3,686

    A good way to cook pickled pork that turns out...

    A good way to cook pickled pork that turns out like leg ham.


    Fire up the webber BBQ with coals get them burnin hot , let them cool down , throw some pine cones in on the coals so they smoke...
  24. Replies
    4
    Views
    728

    QD 132A Compressor Change

    Manitowoc QD 132A Undercounter Ice Machine

    This might seem like a basic question , but does anyone have any ideas on the change out of the original compressor in this system ?

    What would be...
  25. Replies
    64
    Views
    4,411

    There is no condensing of refrigerant so it is...

    There is no condensing of refrigerant so it is called a gas cooler , it boils off at around 32 Degrees c
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event