    Looking for work in Sacramento

    I have worked in controls for over 20 years. I was laid off from my last job due to lack of work (you know it is slow when you are programming controllers for the owner's house). I have worked on...
  2. I have used the USB-COMi-M for both Barber...

    I have used the USB-COMi-M for both Barber Coleman Network 8000 & Johnson N2. It seems to get the job done. Here is the link to Byte Runner for it....
  3. Replies
    3
    Views
    744

    My bad, the baud rate is 2400.

    My bad, the baud rate is 2400.
  4. Replies
    3
    Views
    744

    it uses TTL (Transistor Transistor Logic), in...

    it uses TTL (Transistor Transistor Logic), in other words 0 to 5vdc. Siemens had a converter to RS-485 (around 10 years ago) but that was for interfacing to the MBC, I don't know if they would sell...
  5. Replies
    313
    Views
    56,031

    To start off with your second picture is of a...

    To start off with your second picture is of a PEM, not a LCM. You need PSI (DOS program) or XPSI ("windowfied" DOS program) to backup, restore or program a PEM. Hyperterminal will not do any of...
  6. I tried disabling the driver and all it did was...

    I tried disabling the driver and all it did was make connecting to a ASD device impossible. I did a little more testing & found this happens on any machine, virtual or physical, I installed the...
  7. Replies
    313
    Views
    56,031

    Yes, those files need to be installed. You may...

    Yes, those files need to be installed. You may need to contact the author as I believe the expiration date on the download is passed.
  8. Replies
    313
    Views
    56,031

    I had to look for a backup program for the GCM...

    I had to look for a backup program for the GCM lately & I could only find 1,
    http://quicksilverintegrations.com/downloads.htm
    It works well but costs about $500. I believe the author allows a...
  9. Sorry for not getting back to this thread sooner,...

    Sorry for not getting back to this thread sooner, things have been a bit crazy. I have the serial tunneling correct as far as I can tell. I am using virtual machines & this occurs whether it is an XP...
  10. Niagara Serial Tunnelling & Barber Coleman XPSI

    I am working on a job where we have replaced the GCMs with Johnson FX Jaces. I have tried using XPSI with the serial tunneling to be able to look directly at the PEMs & MZ2s. What I am seeing is that...
  11. Replies
    23
    Views
    4,313

    Could you please send me a copy of both problock...

    Could you please send me a copy of both problock & the licence file?
  12. Replies
    33
    Views
    2,959

    The fact manufacturers are moving away from...

    The fact manufacturers are moving away from Tridium is not surprising. Remember, Tridium made its bones by making a standard way to allow different control systems to talk to each other. Now that...
  13. Thread: PEM Program

    by Ex-Man
    Replies
    2
    Views
    348

    PEM Program

    I have a site with 69 Barber Coleman PEMs that all appear to have the same program. We are replacing the GCM with a jace. The PEM application name (APPL) is 24021VNR. It is controlling fan units with...
  14. Replies
    6
    Views
    514

    N2 to Ethernet convertion?

    I have a high school with an older Johnson system that has the N2 comm wire run underground to the various buildings. The problem is the underground conduit is always getting full of water & messing...
  15. Replies
    1
    Views
    319

    IBSMS driver for Microsmart controllers

    I believe the IBSMS driver is for Robert Shaw MicroSmart controllers.
  16. Replies
    23
    Views
    4,313

    Worked fine for me

    I used Problocks for over 2 years without any real problems, so I am inclined to use it again. The only real problem I had was it didn't completely back up the OSS blocks, it didn't pull in the...
  17. Replies
    23
    Views
    4,313

    I know this thread has been dead for quite awhile...

    I know this thread has been dead for quite awhile but my company had decided to start working on Network 8000. Since I used to work on Network 8000 many years ago I have been tasked with getting a...
  18. Replies
    35
    Views
    3,559

    I would be grateful for a copy of your guide....

    I would be grateful for a copy of your guide. Thanks in advance.
  19. Replies
    1
    Views
    323

    TAC's ASD driver has an object (labelled PSI)...

    TAC's ASD driver has an object (labelled PSI) that has to be installed in the station for PSI to work on the ASD bus.
  20. Replies
    313
    Views
    56,031

    Windows XP was the last version of windows that...

    Windows XP was the last version of windows that any software was made for Network 8000.
  21. Replies
    13
    Views
    4,835

    The K-factor is a fudge factor to get correct air...

    The K-factor is a fudge factor to get correct air flow. It will be different for identical vav boxes because of the ducting. In real life you do not find the recommended 5 to 10 duct diameters of...
  22. Replies
    10
    Views
    1,719

    Where can I find a copy of NUDL?

    Where can I find a copy of NUDL?
  23. Replies
    3
    Views
    600

    Control Man, That may all be well & good, I...

    Control Man,
    That may all be well & good, I realize all good (and not so good things) must come to an end. I don't thing my ex boss was bsing me. He tends to be a bit colorful in his descriptions....
  24. Replies
    3
    Views
    600

    Another Network 8000 Request

    I worked for an Invesys distributor 4 or 5 years ago. My new employer has a number of sites with Network 8000 & wants me to take care of them. I tried contacting the local Shneider Electric dealer,...
  25. Replies
    10
    Views
    1,729

    When I was working at Siemens I would use the...

    When I was working at Siemens I would use the following procedure.
    1. Set P to a large & probably outrageous value, I & D set to zero.
    2. Adjust P down until you get the smallest P value without...
  26. Replies
    9
    Views
    1,665

    Can't find my old CD's

    I can't find my old Insight CD's :(, I haven't worked for Siemens in a quite a while, but I was able to look up the application guide for VAV TEC's on the internet & point 58 is the point to change...
  27. Replies
    9
    Views
    1,665

    Depends on the TEC Application

    What application is the TEC using? Check the application point list. If you can change the action there will be a binary point to change the action. You should then be able to change the action from...
  28. Replies
    6
    Views
    1,948

    Probably Low On RAM

    I haven't worked on Siemens equipment in 5 years now & I haven't worked on their BACNet equipment :rolleyes: but what you describe sounds like the panel is low on RAM. The panel is probably rebooting...
  29. Replies
    13
    Views
    1,151

    Extra Code

    Check to see if there is an object called PSI in the R2. This is required because the ASD driver did not allow for PSI (as a second master) originally. I'm not sure if it is required for tunneling...
  30. Replies
    18
    Views
    1,697

    Your com port should be COM1 or COM2. PSI is a...

    Your com port should be COM1 or COM2. PSI is a DOS program & so can only see those 2 com ports.
  31. Replies
    7
    Views
    984

    GCM Conversion

    You might want to look at Smartware Tech. They are a TAC (formally Invesys, ect. dealer). The claim to be able to convert your GCM database to a R2 data base, for a fee of course. It would be...
  32. Replies
    7
    Views
    998

    RS-485 Driver

    Since your system originally had a GCM & the problem has been around since the UNC was installed, it could be an ASD wiring issue. When Invensys gave Tridium their specs for the RS-485 hardware in...
  33. Replies
    15
    Views
    2,962

    A Possibility

    There is a possibility you have a corrupted node table. It has been a few years since I was at Siemens but let me see if I can explain it. If any of the MEC's & PCX were added to the BLN from one of...
  34. Replies
    2
    Views
    534

    Need the point list

    You need the point list from McQuay. Alerton is bacnet so they do not control the points McQuay chooses to show the system. The board might be a gateway from McQuay's proprietary communications &...
  35. Thread: Siemens FLN

    by Ex-Man
    Replies
    4
    Views
    1,441

    TEC & UC's Oh My

    Siemens TECs have their programs burned into EEPROM at the factory & you can't change them. They use a points list of 0-99. Included are the TEC address, the application number, and the rest are...
  36. Too Old?

    It could be they don't want to deal with a front end as old as yours. Since you mention Powers I am guessing your front end is using at best Win95, more likely Win3.1. They may not have anyone...
  37. Replies
    313
    Views
    56,031

    Network 8000 Programming Manuals

    I have a job coming up that will be replacing 2 GCM's with Jaces using the ASD driver. I need a copys of the GCM, MicroZone2 & PEM programming manuals. Can anyone help me here. I worked for an...
  38. Replies
    7
    Views
    1,738

    In the GCM

    Everything you see on the Signal screen is happening in the GCM. You need to figure out your GCM programming to figure out what is going on.
  39. Replies
    7
    Views
    1,738

    You may be SOL

    There is nothing you can do to program the micronet controllers from Signal. The terminal program is emulating a terminal to the GCM. To program a micronet controller you need the MNET software and a...
  40. Replies
    3
    Views
    632

    What you need

    If you are connecting directly to the MicoZone II what you need is an RS-232 to RS-485 converter. You will also need a cable to convert it to a 6 conductor RJ-11 connection. If you are connecting to...
  41. Replies
    4
    Views
    1,034

    Try TAC

    Try your local TAC contractor. TAC bought the division that supported RobertShaw from Invensys about 2 years ago. That would be the place to start.
  42. Thread: Siemens apogee

    by Ex-Man
    Replies
    12
    Views
    1,687

    Good Luck

    Siemens is a proprietary system:nopity:. Any interfacing is through them and their gateways. The only option is if the card is set up for their FLN protocol, which I would doubt. You may be better...
  43. Thread: Siemens VFD

    by Ex-Man
    Replies
    11
    Views
    1,001

    Keep Hoping

    I took care of a site, in another life, that had Siemens VFD's installed. In the 2 years I was there 3 were replaced and at least 2 others before I got there. So all I can tell you is keep...
  44. Replies
    7
    Views
    666

    Get one from Trane

    Although I haven't worked on Trane my experience is you will probably need to get one from Trane. Modem makers implement their commands differently from each other and differently from one revision...
  45. Replies
    2
    Views
    822

    Its in the mail

    Check your email.:rolleyes:
  46. Replies
    30
    Views
    6,355

    Easier Yet

    You can access the value of a point in one controller by just using its name in the PPCL in another controller. For example if you call the outside air temperature "OAT" you can user "OAT" in the...
  47. Replies
    17
    Views
    1,467

    Do You Want To Start A Flame War?

    I have been in the industry for 24+ years, most of them as a service tech but I have spent a good amount of time on the install side. I could go on about how many sites I have been to that were never...
  48. Replies
    7
    Views
    827

    TAC Choices

    TAC offers a driver for ASD devices for the Tridium R2 & AX (I believe). Of course they want to sell the hardware to you as well. They also have a serial driver for the GCM.
  49. Replies
    17
    Views
    2,404

    This might help

    I've used the USB-COMi-SI-M with Win XP but you can find a Vista driver for it. Here is the web page for it...
  50. Replies
    6
    Views
    824

    MicroFlo2 Discontinued

    Last year I was working for the Barbara Coleman-Siebe-Invensys-TAC rep in the area. At that time I was told TAC was discontinuing the MicroFlo2 at the end of the year. Their tech support said they...