Search:

Type: Posts; User: Controlsman01

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    1
    Views
    239

    This item has been sold. Thank you.

    This item has been sold. Thank you.
  2. Replies
    1
    Views
    239

    Trane Tracer VV550 & 551

    I have 13 VV550 VAV Controllers with the actuators and differential pressure sensors. These were shipped to us from the factory, installed in the VAVs that we purchased, and were replaced with...
  3. I also have 2 ECL-610 controllers, but they have...

    I also have 2 ECL-610 controllers, but they have been opened and used. Still work great, could not add them to an FX system.

    $120.00 each or $200.00 for both. Email is in my profile (click on...
  4. Distech ECL-300 Controllers for sale.

    I have 2 Distech ECL-300 controllers, brand new, in-the-box, never opened. These are left over from a school project that requires Distech only and that was our first and LAST district job. Cost,...
  5. On the 7751G, I had to reconfigure and commission...

    On the 7751G, I had to reconfigure and commission on LONSPEC, but do not recommission on Ax. If you are not using a Honeywell JACE, you will have to change the LonNetmgnt address to Length: 1, Id:...
  6. Replies
    2
    Views
    332

    Thank you! That is the same reason that I am...

    Thank you! That is the same reason that I am here today. Do I set the nviRequest to Manual? It is defaulted to Automatic. Thank you.

    CM01
  7. Replies
    1
    Views
    409

    SOLD! Thank you. CM01

    SOLD! Thank you.

    CM01
  8. These devices have been sold locally. Thank you....

    These devices have been sold locally. Thank you.

    CM01
  9. Replies
    2
    Views
    360

    This NAE has been sold at work. Thank you. ...

    This NAE has been sold at work. Thank you.

    CM01
  10. This post has been sold. Thank you.

    This post has been sold. Thank you.
  11. Replies
    4
    Views
    540

    Alerton point list...

    I have probed many Alerton BACnet MS/TP boards, among them, VLC-1188,
    VLC-853, VLC-444, VAV-SD, etc. If you have a specific part number, I may have a text file with the instance number, vendor id,...
  12. >>>SOLD

    These are actuators that are left from my business for which I am paying storage. There will be more parts to come. My wife has spoken, "we have far exceeded the net worth of the parts in what we...
  13. Replies
    2
    Views
    360

    Picture of the NAE..

    http://hvac-talk.com/vbb/picture.php?albumid=3031&pictureid=17331
  14. Replies
    2
    Views
    360

    >>>SOLD

    Hello all:

    I replaced an NAE today with an FX-60 and the owner told me that he spent way too much money to (un-named company) to maintain that thing. Trash it.

    One persons trash is another...
  15. lowdrive, Alerton Key...

    Lowdrive:

    The key is an Alerton ENV-BT-2.6-MED.

    If you are still interested please email me. My address is in my profile, just click on my name above.

    CM01
  16. Replies
    11
    Views
    773

    I have a whole boatload of display files,...

    I have a whole boatload of display files, graphics, VisioLogic templates, etc. I don't know if you need something specific to your job, but I have the whole library. My email address is in my...
  17. Which key?

    Unfortunately, I am not an Alerton person. I removed these controls from a building where the owner was EXTREMELY pissed at the installer. It seems that they installed the controls on the heat side...
  18. Replies
    2
    Views
    626

    Welcome...

    Thank you. Glad to be here.
  19. Replies
    2
    Views
    398

    NAE1 Thank you.

    BrunoRoad:

    Thank you for your help. I hope I can return the favor in the future.

    Sincerely, CM01
  20. http://hvac-talk.com/vbb/picture.php?albumid=3031&...

    http://hvac-talk.com/vbb/picture.php?albumid=3031&pictureid=17311

    This is a picture the Alerton Devices for sale from controlsman01.
  21. Replies
    12
    Views
    892

    You may have to disconnect the I-vue temporarily...

    You may have to disconnect the I-vue temporarily and use the service tool to change the addresses. Once you have a clean scan and discovered all of the components, you can connect a keyboard, mouse,...
  22. Replies
    26
    Views
    2,220

    ASAP: Always say a prayer before opening the...

    ASAP: Always say a prayer before opening the panel...
  23. Replies
    2
    Views
    398

    Metasys NAE1 Static IP

    Good morning all:

    I took over a building that had a JCI Metasys system installed with no front end. I replaced the NAE1 with a JCI FX-60 JACE. The JC tech was nice enough to leave the prn files...
  24. Replies
    7
    Views
    806

    N2 protocol explaination...

    Are you trying to write to the N2 via FX? If so, you will need the JCI LX productivity tools to access the wizards. If I understand correctly, you are trying to program an FCU controller, which is...
  25. Replies
    20
    Views
    2,527

    3D Floorplans...

    Google Sketchup has tremendous support and provides a full library of files that can easily be modified to meet your needs for floorplans. Once you download the program, you will have full access to...
Results 1 to 25 of 29