Search:

Type: Posts; User: jdservice

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    21
    Views
    1,742

    Good thing its only produce!! Next they will do...

    Good thing its only produce!! Next they will do the same with the meat case at Thanksgiving....
  2. Replies
    60
    Views
    11,567

    Tif ZX1 will find the leak.

    Tif ZX1 will find the leak.
  3. Replies
    53
    Views
    3,862

    Split and wash out the "inside condensor". Pull...

    Split and wash out the "inside condensor". Pull the top off where the condensor fans are located. Set the whole condensor fan assembly on the top of the unit. Thats why you have all that extra...
  4. Thread: Racked

    by jdservice
    Replies
    35
    Views
    2,714

    Sounds like the TXV is not working. Maybe try...

    Sounds like the TXV is not working. Maybe try replacing the powerhead. Its a lot easier then replacing the valve.
  5. Replies
    8
    Views
    696

    Had new E2 installed during recent upgrade at one...

    Had new E2 installed during recent upgrade at one of my accounts by another contractor. The mechanic from Source was Justin. Cool guy that I met in Petaluma.
    More power to them for trying to save my...
  6. Replies
    12
    Views
    1,396

    We did a major rebuild of a 1959 Ray Winther...

    We did a major rebuild of a 1959 Ray Winther installed TD system in San Rafael,Ca last spring. Due to space concerns at the market the customer chose to rebuild as opposed to replacing. It was a...
  7. Replies
    194
    Views
    19,344

    If you install a sight glass on the discharge...

    If you install a sight glass on the discharge line of compressor. It said Hill on that guys shirt.
  8. Replies
    194
    Views
    19,344

    If you install a new lineup of meat cases and...

    If you install a new lineup of meat cases and your crew cuts one of the rails with a torch and blows molten steel
    all over the customers new floor tiles. I think they will be paying to replace about...
  9. Replies
    11
    Views
    1,066

    You need to have a suction accumulator on low...

    You need to have a suction accumulator on low temp applications and with R-22 it needs all the cold it can get on the hot days. Should be insulated. Also crank case heaters are installed on most low...
  10. Replies
    2
    Views
    575

    Try setting all the head pressure controls for a...

    Try setting all the head pressure controls for a 70 degree condensing temp. This will most likely be quite a bit lower then it is set for now and will save money. Wash out the condensors 2 times per...
  11. Replies
    7
    Views
    1,165

    Sounds like a problem with the design, the piping...

    Sounds like a problem with the design, the piping or both.
    What suction pressure did those units run during normal operation.
  12. Replies
    17
    Views
    1,475

    Those compressors don`t have handles on them for...

    Those compressors don`t have handles on them for a reason.
    Chain fall is the only way roll. I have changed a couple of 3D 10HP solo but not by choice. Both were also one on one systems. To hard to...
  13. Thread: rmcc panel

    by jdservice
    Replies
    6
    Views
    840

    What questions do you have? I have a manual handy.

    What questions do you have? I have a manual handy.
  14. Replies
    2
    Views
    510

    Have a Recold tube bundle in a JC-165 to change...

    Have a Recold tube bundle in a JC-165 to change out. Bundle is solid rock and has already had passes cut out of the low temp due to leaks. The new bundle is 1600 pounds shipping weight. I think we...
  15. Thread: wages

    by jdservice
    Replies
    2
    Views
    750

    42.00 dollars per hour plus paid health and...

    42.00 dollars per hour plus paid health and welfare and paid pension and paid 401A supplemental pension. Total package around 60.00 dollars per hour. I worked 3000 hours last year doing only market...
  16. Replies
    22
    Views
    1,470

    How about the Einstein E2. It seems to work well....

    How about the Einstein E2. It seems to work well. Really do like the RMCC. Just started up a store in 04 that had 6 RMCC controllers. We do have one store in our area with Danfoss. Have had no...
  17. Replies
    5
    Views
    732

    Dave are you tellin me you run the evaporator...

    Dave are you tellin me you run the evaporator temp 10 degrees above design and that works without a problem. What kind of product do you get in the bin? Have been told by Howe to lower temp to -10...
  18. Replies
    22
    Views
    1,470

    Sorry Dave I just have a sour taste after being...

    Sorry Dave I just have a sour taste after being told by the aftermarket parts distributer for the "global" company I worked for that if I had a bad Sporlan Sol. coil that it would be more profitable...
  19. Replies
    50
    Views
    4,824

    Our shop is in Santa Rosa. We pretty much cover...

    Our shop is in Santa Rosa. We pretty much cover all of the wine country down to the bridges. We don`t cross the bridges, plenty of work up here. Does everybody know about the TD system were talking...
  20. Replies
    41
    Views
    11,987

    Had my first ZX1 for two years with no problems....

    Had my first ZX1 for two years with no problems. Started having charging problems and replaced battery. I think the key is to have a sensor for R-22 and blends and another one for HFC refrigerants. I...
  21. Replies
    22
    Views
    1,470

    Lets start direct depositing all of our money...

    Lets start direct depositing all of our money into Finlands economy, and while were at it lets give praise to GE for making 9W motors in China. Bet those workers in Garrett Indiana were stoked about...
  22. Replies
    5
    Views
    732

    Has any body out there had problems with Howe ice...

    Has any body out there had problems with Howe ice flakers connected to rack systems? Got a 3000 RLE connected to a 6 compressor Protocol system. Lots of problems with the barrel icing up. Have been...
  23. Replies
    50
    Views
    4,824

    We still have plenty of TD systems running in...

    We still have plenty of TD systems running in northern CA.
    We still have an original Ray Winther install from the early 1960's that is still running!. I have seen Raleys retrofit a TD to R-404A!...
  24. Replies
    41
    Views
    11,987

    Well if Raleys uses it, they must be the...

    Well if Raleys uses it, they must be the best.LOL. What a hoot. Tif ZX-1 will find more leaks then you will want to fix. It will get you close enough to find it with either soap bubbles or with R-22...
  25. Replies
    19
    Views
    1,711

    Shoppers just go about their buisness while the...

    Shoppers just go about their buisness while the SMOKE escapes from the kneeknocker case.Do I smell a faint odor of juicy fruit gum in the air? At least its O-ZONE friendly. Nice day to own the...
Results 1 to 25 of 44
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event