  1. Replies
    1
    Views
    50

    I would imagine that you could do it with Static...

    I would imagine that you could do it with Static or DHCP. Some home routers won't allow a static IP to attach to the network and you either have to add a static route in the router or enable it to...
  2. Replies
    6
    Views
    312

    What is your network infrastructure? Do you have...

    What is your network infrastructure? Do you have the GX tool or HVACPro and cables?
  3. Have you tried to discover the points with a 3rd...

    Have you tried to discover the points with a 3rd party solution like YABE?
  4. What version of NAE are you running? What BACnet...

    What version of NAE are you running? What BACnet encoding type are you trying to use?
  5. Replies
    1
    Views
    140

    At version that old you have to use IE6 and...

    At version that old you have to use IE6 and depending on the patch that is applied to the NAE either 1.3.1_15, 1.5.0_04, _06 or _11. You should probably contact your local JCI office to get them to...
  6. Replies
    1
    Views
    130

    Not sure what you mean by this, but the NIC tool...

    Not sure what you mean by this, but the NIC tool is JCI proprietary. You could try to purchase it from your local branch but it is doubtful.
  7. Replies
    24
    Views
    4,532

    You've got mail.

    You've got mail.
  8. Replies
    2
    Views
    312

    When I worked for JCI they sent me to the FEC...

    When I worked for JCI they sent me to the FEC class, DX-9100 class, and the LON class. The beginner level classes are not very useful if you have experience in the field. The only class that I got...
  9. Try this:...

    Try this: http://www.csimn.com/CSI_pages/VP4-23-mstp.html

    What system do you have? A lot of older protocols can now be translated to BACnet using a gateway so you could pull the chiller into your...
  10. Replies
    1
    Views
    186

    PPCL is just stored as a text file. You can...

    PPCL is just stored as a text file. You can technically edit it with notepad, but you should use program editor as it has all of the syntax checking and point resolution built in. If you have an...
  11. The maximum length for an Ethernet cable run is...

    The maximum length for an Ethernet cable run is 100 meters or 328 feet. You were already exceeding that before you moved the server and you made it worse by extending the cable. Adding a switch isn't...
  12. What exactly does the vendor expect the FX07 to...

    What exactly does the vendor expect the FX07 to do, the Modbus-RTU? What connections are available on the refrigeration product? From the looks of it the Xweb500 talks Modbus-RTU to the devices but...
  13. Is the NAE at 5.0? If you do an insert field...

    Is the NAE at 5.0? If you do an insert field device you can re-run the auto discovery and it should rediscover your devices. If you deleted the device but it is still on the bus then the auto...
  14. Replies
    3
    Views
    153

    Does the point latch when it is commanded? I have...

    Does the point latch when it is commanded? I have had issues with these modules before where they don't latch. Not sure of the cause but I cycled power and it started working.
  15. Replies
    3
    Views
    244

    You've got mail. I have never used the tool...

    You've got mail. I have never used the tool personally, but you will probably have to run the tool on the archive machine.
  16. This is a Lab Pressure Controller with Hot Water...

    This is a Lab Pressure Controller with Hot Water Reheat. I have run into a few of these at a lab that utilize the fast acting actuators for the exhaust and supply.

    Here a list of the points in the...
  17. Replies
    4
    Views
    259

    In hand the module should change as you move the...

    In hand the module should change as you move the slider. You might try and remove the signal line from the module and see if it will move that way. I have had to replace a ton of these modules at a...
  18. Replies
    5
    Views
    500

    I don't think this will work as with BACnet part...

    I don't think this will work as with BACnet part of the required message is the Object Type. If you are polling a Multi-State but telling it that you want an Analog Value I don't believe it will...
  19. Replies
    1
    Views
    235

    Metasys version 4 does not support login from a...

    Metasys version 4 does not support login from a 64bit machine. I don't believe that they supported 64bit til version 6. You can try installing the launcher and see if it will launch.
  20. Thread: Siemens TEC ?

    by NickDeal
    Replies
    3
    Views
    203

    If you are not using WCIS you won't see the raw...

    If you are not using WCIS you won't see the raw value. Is global commander reporting a successful command? What version of Insight are you using?
  21. Thread: Siemens TEC ?

    by NickDeal
    Replies
    3
    Views
    203

    Is the Raw value changing for the point? What...

    Is the Raw value changing for the point? What version of WCIS are you using? Version of the 2023 application?
  22. Replies
    1
    Views
    255

    I don't have experience with that particular...

    I don't have experience with that particular version but I have used BabelBusters on several jobs and recommend them. They are easy to configure and for the most part are stable. I had some issues...
  23. Replies
    15
    Views
    1,420

    I don't know about other countries and I don't...

    I don't know about other countries and I don't currently work for JCI, but when I was with them and after when I worked for a large customer a computer loaded with AIM tools was not available for...
  24. Replies
    15
    Views
    1,420

    You can't buy the point schedule. Someone gave it...

    You can't buy the point schedule. Someone gave it to him and if JC knew about it they wouldn't be happy. Nowadays they have it so tied to the branch laptops that it won't work outside of a full blown...
  25. Replies
    11
    Views
    537

    http://cgproducts.johnsoncontrols.com/CAT_PDF/1900...

    http://cgproducts.johnsoncontrols.com/CAT_PDF/1900195.pdf?x=2522#xml=http://cgproducts.johnsoncontrols.com/search_lit.aspx?cmd=pdfhits&DocId=275&Index=C%3a%5cinetpub%5cwwwroot%5c72%2e3%2e145%2e66%5cqu...
Results 1 to 25 of 151
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event