  1. Replies
    15
    Views
    2,689

    I have seen this a couple of times before. One...

    I have seen this a couple of times before. One was leaking at the Baso because it was loose and the other was leaking around the temp setting stem. More often I've found the burner tube nut loose,...
  2. I've seen this a few times when years ago the...

    I've seen this a few times when years ago the local utility company offered rebates for switching to natural gas appliances. If installing a gas furnace and keeping the outdoor unit of a heat pump...
  3. Replies
    26
    Views
    4,479

    Personally, I use plastic leaf bags. They take up...

    Personally, I use plastic leaf bags. They take up less room and are easier to carry on the truck. They are waterproof. And they have a built in indicator of a flame roll out or overheating. Plus if...
  4. Replies
    13
    Views
    843

    I haven't run into a 410 system with a small or...

    I haven't run into a 410 system with a small or undersized linesets, so I'm curious as to the higher pressure and velocities causing noise and or wear problems.
    I should say yet.
  5. Replies
    13
    Views
    843

    Exactly!

    Exactly!
  6. Replies
    13
    Views
    843

    I've noticed since the jump in copper prices,...

    I've noticed since the jump in copper prices, some makers have backed off the 3/8 min size for liquid lines, but with a reduction of capacity. However if they do call for that, you will void the...
  7. Replies
    11
    Views
    1,364

    Just spoke with my supplier and they are not even...

    Just spoke with my supplier and they are not even allowed to sell any. They have heard the price will be settling back down, but still about 20% higher than last week, after the next few days.
  8. Replies
    18
    Views
    3,590

    Anyone can see he didn't know what he was doing....

    Anyone can see he didn't know what he was doing. Everybody knows you don't put screws in PVC......you use a No-Hub Band!
  9. Well I'll tell you I had a similar situation...

    Well I'll tell you I had a similar situation several years ago. As a matter of fact I was working just around the corner from there today. I got a call at 3am from a customer who handed the phone to...
  10. Replies
    74
    Views
    6,222

    Check the burners and the crossover slots. Those...

    Check the burners and the crossover slots. Those burners can get enough lint, pet hair, etc buildup that can delay the lightup just enough for the flame sense circuit to open. The older WAV burners...
  11. Replies
    585
    Views
    99,356

    Also had a customer with no heat whose husband...

    Also had a customer with no heat whose husband decided to save some time by venting the dryer into the chimney. I have never seen so much lint packed into a heat exchanger flueway before or since. ...
  12. Replies
    585
    Views
    99,356

    Years ago, had a customer call about a gas leak....

    Years ago, had a customer call about a gas leak. Was sent out to check it. Walked in the basement to see some bad looking corroded pipe with a garden hose between it. The man said he knew it was...
  13. Replies
    14
    Views
    2,982

    Well it may be possible they gave the guy a high...

    Well it may be possible they gave the guy a high price intentionally so he would call someone else
  14. It does make a nice place to set your tools....

    It does make a nice place to set your tools. They'll be at arms reach
  15. Replies
    25
    Views
    4,967

    If you've been getting your septic tank pumped...

    If you've been getting your septic tank pumped out regularly and don't run any heavy vehicles, etc over the field you shouldn't have a problem. if only liquid is going out to the drain field there...
  16. Thread: pex tubing

    by KEFCOPRES
    Replies
    12
    Views
    1,261

    Unfortunately, the ability to read or understand...

    Unfortunately, the ability to read or understand what your reading is not a requirement round here. And from what I see, it is well exploited.
  17. Replies
    25
    Views
    4,967

    Where in Virginia How old is the house? Has it...

    Where in Virginia How old is the house? Has it been renovated? do you know what type of drain piping you have? The smell you are describing sounds more like sewer gas/ drain odor and could have one...
  18. It sounds like you need some clarification from...

    It sounds like you need some clarification from the salesman before you decide.
  19. Thread: pex tubing

    by KEFCOPRES
    Replies
    12
    Views
    1,261

    That is why I am not a believer in pex for...

    That is why I am not a believer in pex for heating purposes. I too have seen many boilers where the high limit gets out of calibration and runs up to 220 or more. Around here we have some houses that...
  20. Thread: pex tubing

    by KEFCOPRES
    Replies
    12
    Views
    1,261

    Does everyone has a driver's license know how to...

    Does everyone has a driver's license know how to drive? I think the reply that Gib's Son just made is going to be the correct final one. We had a meeting with the area's inspectors years back and...
  21. Replies
    3
    Views
    1,467

    I've had luck with Clenair neutralizer tubs...

    I've had luck with Clenair neutralizer tubs placed in the returns and AHU. You need plenty and they're not cheap, but it removes odor. I had luck with those bags of lava rocks sold at BGBX store work...
  22. I would recommend you get a qualified HVAC...

    I would recommend you get a qualified HVAC mechanic to come out and go over your system and explain/show you what can/cant/needs to be done. Minor variables can require different answers to the same...
  23. Thread: pex tubing

    by KEFCOPRES
    Replies
    12
    Views
    1,261

    Yes I agree,. That is a question the installer...

    Yes I agree,. That is a question the installer should answer. Did it pass a rough in inspection?
  24. Ask your contractor to provide you with some...

    Ask your contractor to provide you with some product brochures or data. It may simply be a typo. I myself had spelled out an incorrect model number a time or two on an estimate.
    Some combinations...
  25. Replies
    7
    Views
    2,167

    All you have to do is soak down the wires with...

    All you have to do is soak down the wires with WD40 and they"ll work in water just fine.
Results 1 to 25 of 37