Search:

Type: Posts; User: SoFlaDave

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. I apologize if this had been brought up already...

    I apologize if this had been brought up already but there are a few things to address.
    1: Ductless mini splits run the indoor fan constantly to keep air moving over the temperature sensor and they...
  2. Yeah, its against building code to seal the eaves...

    Yeah, its against building code to seal the eaves at least in my area.
  3. The ducts sweat because the dewpoint raises as...

    The ducts sweat because the dewpoint raises as the temp drops and humidity goes up. We get that all the time down here on houses with spray foamed attics. The temperature in the attic stays in the...
  4. Replies
    59
    Views
    2,557

    Yes eventually it would freeze up if it ran long...

    Yes eventually it would freeze up if it ran long enough.
  5. Thread: Bad cap

    by SoFlaDave
    Replies
    33
    Views
    1,298

    Congrats on learning another valuable diagnostic...

    Congrats on learning another valuable diagnostic lesson! Also, the 5-2-1 start kit is the only way to go.
  6. The tstat has it's own bridge but you need a...

    The tstat has it's own bridge but you need a dedicated bridge for the locks,lights etc.
  7. It sounds like a failed TXV. The filter drier is...

    It sounds like a failed TXV. The filter drier is on the inside of the condenser so unless he installed a second one outside of the condenser he would not be reading high pressure on the liquid line....
  8. Thread: Work Pants

    by SoFlaDave
    Replies
    32
    Views
    2,118

    We started buying TruSpec cargo's from an army...

    We started buying TruSpec cargo's from an army surplus place and they are phenomenal. Light weight but tear resistant tons of pockets and really comfortable. Nice price as well.
    ...
  9. Not in the case of these units, no. If you...

    Not in the case of these units, no. If you absolutely need it sealed just for piece of mind than use anything but foil tape and on the exterior only.

    There are gaskets and rings that need to be...
  10. Replies
    7
    Views
    474

    I have no idea what the differences are because...

    I have no idea what the differences are because their website description is identical on both models. Not a fan of the gauges because they crack easily but I hate all plastic gauges really. I put...
  11. Sealing the panels on these units is a waste of...

    Sealing the panels on these units is a waste of time and energy IMO. Anyone that puts foil tape all over an air handler is a terrible person and should be deported to a remote island lol.
  12. The price varies significantly across the country...

    The price varies significantly across the country that's why no one is answering that question. I will tell you that the entire system is under warranty till 2015 and there is no way it should cost $...
  13. Replies
    895
    Views
    63,373

    That would be great Jim. My android device just...

    That would be great Jim. My android device just died and I switched to a windows device and I miss the app already. With the Microsoft Surface 3 looking very promising I hope you guys can make it...
  14. Replies
    895
    Views
    63,373

    Not sure whether its been asked or not, but are...

    Not sure whether its been asked or not, but are there any plans for a Windows phone app?
  15. Replies
    895
    Views
    63,373

    Just wanted to say that even without the hardware...

    Just wanted to say that even without the hardware the app is fantastic! I got some good practical use out of the performance calculations today just plugging in data from my other hardware and...
  16. Replies
    12
    Views
    1,542

    I submitted my resume. Have you been with them...

    I submitted my resume. Have you been with them since you moved down here, Nutshell?
  17. Replies
    12
    Views
    1,542

    PM sent. Forgot to mention I also have some...

    PM sent. Forgot to mention I also have some electronics engineering experience if it's applicable to the position.
  18. if its a mechanical fitted TXV there is no way to...

    if its a mechanical fitted TXV there is no way to put it in backwards because its male on one side and female on the other.
  19. The XV series will only work with a TAM8C air...

    The XV series will only work with a TAM8C air handler. I would put that contractor in last place on your list of bids.
  20. We just put our first XV20 in yesterday and it is...

    We just put our first XV20 in yesterday and it is an incredible piece of engineering. The XL950 controller is extremely user friendly and the Nexia remote access is free if the controller is the only...
  21. Replies
    7
    Views
    790

    They used to go by the first letter which was...

    They used to go by the first letter which was assigned to the year. Someone surely has the date code table around here.
  22. Replies
    21
    Views
    1,585

    In related news, I sent my 6 year old Fieldpiece...

    In related news, I sent my 6 year old Fieldpiece HS36 that the temp went out on and it was $60 + shipping to them only :)
  23. +1 Bad cap is the most common reason for this.

    +1 Bad cap is the most common reason for this.
  24. Replies
    18
    Views
    1,193

    It's more to do with the compression ratio, the...

    It's more to do with the compression ratio, the difference between low and high side that effects amp draw. Typically in air conditioning applications the ratio is 3:1 for example 70 PSIG suction and...
  25. I think all the pro's here are, or should be...

    I think all the pro's here are, or should be grateful to the OP for hiring a licensed contractor and I personally hope that he is satisfied with the installation. We all love installation pics here....
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event