Search:

Type: Posts; User: subdewd

Search: Search took 0.00 seconds.

  1. Replies
    15
    Views
    1,202

    RoBo that's hilarious, Here you are giving all...

    RoBo that's hilarious, Here you are giving all this great advice on all the latest hvac equipment and you run window units?
  2. Replies
    27
    Views
    2,340

    I've got a similar system and it's great except...

    I've got a similar system and it's great except I'd use a true 3 stage tstat. The vision pro won't control the back up rather relies on the furnace's control to time it in. I think white rogers has a...
  3. Replies
    0
    Views
    470

    Anyone recommend an install contractor near...

    Anyone recommend an install contractor near Nassawadox VA?
    Job involves installing Ductwork, AH and conpmressor.
  4. Replies
    13
    Views
    2,419

    Wont work for 3 stage if 1 is HP and 2/3 are gas....

    Wont work for 3 stage if 1 is HP and 2/3 are gas. Ask me how I know. You need a different Tstat or use the 2 stage setting and let the furn. hickon hi @ 10 min. Or get a white rogers which supposedly...
  5. Good reason to have pre-season checkout, Couldn't...

    Good reason to have pre-season checkout, Couldn't you fire up the aux and for the a/c to melt the coil?
  6. Replies
    9
    Views
    1,753

    On the plus side if you or your contractor has a...

    On the plus side if you or your contractor has a problem
    you can ask RoBo!
  7. Replies
    9
    Views
    1,753

    Deep down you know what to do, If #3 treata you...

    Deep down you know what to do, If #3 treata you like this before he even has a contrct how do you think it will be after he's cashed your check, Don't they have any other rheem dealers? I had a...
  8. Replies
    18
    Views
    1,804

    I had a GMV90 installed and as someone stated...

    I had a GMV90 installed and as someone stated earlier
    it's really hard to know if the fan is on in circ mode.
    According to the lit. they left with me the blower is
    56% of the high stage cooling. ...
  9. Replies
    18
    Views
    5,679

    I keep lowering mine. Started at 40 dropped to...

    I keep lowering mine. Started at 40 dropped to 35,30
    now @ 25 in st. louis. 2 story 8"cement block with 4"
    brick. New windows and 8" blown in attic. Was down to
    20 last night so gas finally...
  10. Replies
    22
    Views
    2,398

    had a Goodman 93 variable speed w/ 3.5t HP...

    had a Goodman 93 variable speed w/ 3.5t HP w/90/60 2 stage aux heat installed last month.
    Just got my electric bill $65 w/434 degree days
    compared to $50 w/0 degree days last month. Tstat set @ 68....
  11. Replies
    15
    Views
    1,314

    Yeah thanks that's where the confusion is and the...

    Yeah thanks that's where the confusion is and the work around seems to be an external relay.
    That or go with the white roger 371 I think. Funny
    I posted asking for people to compre the two and...
  12. Replies
    15
    Views
    1,314

    That figures jultzya, so how about stage three?...

    That figures jultzya, so how about stage three? which is gas stage 2. So far the closest thing I can see is just set the VP to 2 stage and let the furnace time from low to high output.The Vp...
  13. Replies
    2
    Views
    724

    Do you have a squirrel in the squirrel cage...

    Do you have a squirrel in the squirrel cage blower?
  14. Replies
    15
    Views
    1,314

    yeah that'll work, Run the call for stage 1 HP...

    yeah that'll work, Run the call for stage 1 HP through NC
    contracts. Have the call stage 2 through coil and NO contacts to W1 on furnace. Call stage three straight to W2 on furnace. You would think...
  15. Replies
    15
    Views
    1,314

    OK so can you say how it, namely the VP would be...

    OK so can you say how it, namely the VP would be used with a 2 stage fossil back up? They have aux and emergency terms.
    Y is first srage (HP), second is Aux? or is it put Y2 on
    first stage of the...
  16. Replies
    15
    Views
    1,314

    that's a thermister not a tstat

    that's a thermister not a tstat
  17. Replies
    15
    Views
    1,314

    OK. You would think the firmware would keep that...

    OK. You would think the firmware would keep that test
    from being available with Single stage chosen as option
    during setup. Is the white rogers 3 stage a better choice?
    Or does that need to be...
  18. Replies
    15
    Views
    1,314

    I have read that the vision pro 8321 is a 3 stage...

    I have read that the vision pro 8321 is a 3 stage t-stat
    however there seems to be the opinion that it can't be used on 1 stage
    heat pump w/2 stage fossil back-up.
    I like the technology of the VP...
  19. Replies
    10
    Views
    946

    Thanks the honeywell looks awsome hopefully...

    Thanks the honeywell looks awsome hopefully functional and durable as well. Anyone on have experience with White Rogers
    they make a 3 stage also. ...
  20. Replies
    10
    Views
    946

    I am planning on getting the system replaced in...

    I am planning on getting the system replaced in my home Currently 4T a/c and 100btu old nat gas furnace.
    I've seen people talk about duel fuel which is the way I think I should go here in Missouri....
Results 1 to 20 of 20