    Sometimes I think we have lost a simple thing...

    Sometimes I think we have lost a simple thing called common sense, and a sense of what's right and wrong. How do you dicern a crime is being committed through a closed door? Screaming? Maybe it's the...
  2. Replies
    7
    Views
    668

    Don't know about batteries, but I have an ammeter...

    Don't know about batteries, but I have an ammeter that I have problems

    with when taking it from the cold van to a warm house or if working outside

    in rain or snow. Believe it is moisture...
  3. Replies
    35
    Views
    2,058

    Hot Shot is a replacement for R-12. Can't use for...

    Hot Shot is a replacement for R-12. Can't use for R-502.
  4. Replies
    39
    Views
    11,676

    All of your readings are on the lo side...

    All of your readings are on the lo side indicating a lo load. You mentioned ice on coil and

    suction line. You may have been still iced up. You have to look at both sides to verify

    that it is...
  5. User Interface. Ploease don't give DIY here.

    User Interface.

    Ploease don't give DIY here.
  6. Replies
    31
    Views
    2,246

    Oops, I knew that. Don't know what I was...

    Oops, I knew that. Don't know what I was thinking. Guess I wasn't.
  7. Replies
    31
    Views
    2,246

    Aren't Goodman RV's energized in heat mode? If...

    Aren't Goodman RV's energized in heat mode? If the RV is stuck, shouldn't he be getting

    conditioned air in either mode, just not the condition he wants? Is the heat he is getting

    coming from...
  8. Replies
    4
    Views
    1,834

    We install Carriers which are made by...

    We install Carriers which are made by Climatemaster so I am going to assume some

    things to be the same, but they may not be. If your water loop is what is called an open

    loop,the unit may be...
  9. Replies
    9
    Views
    1,601

    Don't know what manufacturers pressurize to nor...

    Don't know what manufacturers pressurize to nor why. The lo side on a heat pump

    becomes the high side and sees working pressures higher than that, 410a substatially

    higher. A/C only,R22 ,left...
  10. Replies
    9
    Views
    1,601

    Can you tell us what his reason is or is it a...

    Can you tell us what his reason is or is it a secret?
  11. Replies
    10
    Views
    830

    Might want to make sure your stat is not set to...

    Might want to make sure your stat is not set to Em. Ht. before you call. In em. ht.

    mode the electric heat will run, the ht. pump won't. Kind of an obvious thing but it

    sounds like you are not...
  12. Replies
    7
    Views
    1,064

    If I understand the O.P. correctly, the space...

    If I understand the O.P. correctly, the space temp displayed on the stat is 45 degrees.
    Is that true?
  13. Hi voltage does not have to be present at O.D....

    Hi voltage does not have to be present at O.D. unit to display O.D. temp.

    Cooling load in our area does not justify Two stage cooling only. We sell

    Infinity heat pumps only. They come with O.D....
  14. Replies
    37
    Views
    3,412

    There is no heated air from the furnace, heat...

    There is no heated air from the furnace, heat pump and furnace do not run

    at the same time.
  15. Replies
    3
    Views
    496

    Don't know who "advised" you, but that is not...

    Don't know who "advised" you, but that is not even close to right.

    Can't give you instructions, against the rules. Kinda surprised someone

    sold you that control.
  16. Nathan, remove your e-mail from your post. It's...

    Nathan, remove your e-mail from your post. It's not allowed. Labor rates will

    vary from region to region, even between companies in the same area.

    Contact a couple of contractors in your area...
  17. Replies
    14
    Views
    10,304

    Is there a reason they can't include a wiring...

    Is there a reason they can't include a wiring diagram of the switch in the package?
  18. Replies
    9
    Views
    1,031

    Wow. I was taught (by a manufacturers service...

    Wow. I was taught (by a manufacturers service rep) that all I needed was a hole in duct and insert hose or cover the hole w/ hose for static pressure.
    He even demonstrated by removing a screw and...
  19. Replies
    199
    Views
    8,707

    Idaho

    Idaho
  20. Replies
    20
    Views
    1,280

    Off topic but jmacOO mentioned zucchini. Early...

    Off topic but jmacOO mentioned zucchini. Early 70's a bunch of my hippie
    friends rented 6 acres of ground and planted some vegetables. It was
    "practice" for when we came out west to start a...
  21. After registering, I lurked for a year. Got brave...

    After registering, I lurked for a year. Got brave and wanted to post but
    couldn't. Hooked up with Boss, he couldn't tell me what the problem was
    (security thing I guess). Asked him if he could kick...
  22. When Boss was running the show I got kicked off...

    When Boss was running the show I got kicked off without ever posting.
    Always wondered if that might be a record.:)
  23. Replies
    15
    Views
    7,444

    Don't rule out the sewer gas comment. Have had...

    Don't rule out the sewer gas comment. Have had three calls for gas leaks
    that were solved by pouring water into dried out open traps.
  24. Replies
    12
    Views
    1,421

    Thanks for the replies. Tag on compressor said...

    Thanks for the replies. Tag on compressor said MIN. No markings to indicate
    field changes. I put 3GS in it.
  25. Replies
    12
    Views
    1,421

    Compressor Oil

    Got an MRA20500TFC800 Compressor, low temp, 502. Needs a little oil.
    I know it's mineral oil but don't know the viscosity. What can I use? I have
    3GS and 4GS available right now.