Search:

Type: Posts; User: vegaman04

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    174
    Views
    23,067

    What are you trying to change?

    What are you trying to change?
  2. Replies
    14
    Views
    736

    Here is one, kinda dirty but for sale.......

    Here is one, kinda dirty but for sale....
    http://www.ebay.com/itm/Alerton-Bactalk-Stat-MS-2000-BT-/360868911332?pt=LH_DefaultDomain_0&hash=item54057698e4
  3. USB to 25 pin Parallel port ( DB-25 or IEEE 1284 ) Adapter?

    Anyone have any success using a particular USB to 25 pin Parallel port ( DB-25 or IEEE 1284 ) Adapter that works with Aladdin hardlock key(s)? Thanks
  4. Replies
    2
    Views
    371

    The 3 flashes means that there is full...

    The 3 flashes means that there is full communications. It does not act like a error code for control operation troubleshooting. You will need to extract the program and diagnose.
  5. That's why I have 2 rolls, the cheap stuff for...

    That's why I have 2 rolls, the cheap stuff for when pulling wire or doing something quick / temporary. When terminating use the better stuff, at $4.00 a roll it adds up quick especially when the...
  6. Thread: Alerton VLC

    by vegaman04
    Replies
    2
    Views
    573

    Did you recently try sending the ROC file?

    Did you recently try sending the ROC file?
  7. Thread: Alerton-WEB

    by vegaman04
    Replies
    11
    Views
    1,068

    The problem is unless you have a backup of the...

    The problem is unless you have a backup of the original job, you will be rebuilding all the displays, graphics etc. No easy way to do this without a original copy.
  8. Replies
    10
    Views
    1,251

    BTW-Key-3 serial is good up to 1.3. Serial tech...

    BTW-Key-3 serial is good up to 1.3. Serial tech keys are good to 2.6. 3.0 is software only. The biggest issue is newer pc's and laptop's no longer have serial ports to service older jobs so...
  9. Maybe I'm not understanding the OP, but if you...

    Maybe I'm not understanding the OP, but if you send an alarm email from ebt, the recipient would be cellnumber@tmomail.net, it will spit it out for you.
  10. Why not send alarms directly to your phone via...

    Why not send alarms directly to your phone via text?
  11. Replies
    12
    Views
    880

    Do you have a transfer setup, are you using a...

    Do you have a transfer setup, are you using a sub-routine for vav's?
  12. Replies
    2
    Views
    432

    What kind of controllers are in the field? Is...

    What kind of controllers are in the field? Is this an ibex to bactalk conversion? What baud rate are you running at? Have you tested the comm. cables?
  13. Replies
    8
    Views
    2,014

    The original poster never said if he was a end...

    The original poster never said if he was a end user or mechanical contractor like i asked earlier. I have heard for some dealers in IL that mechanical contractors are buying parts from other dealers...
  14. Replies
    8
    Views
    2,014

    Are you a end user or a Mechanical contractor?

    Are you a end user or a Mechanical contractor?
  15. Replies
    15
    Views
    3,094

    Then i guess your not. I dont know the limits of...

    Then i guess your not. I dont know the limits of dropbox. brb
  16. Replies
    10
    Views
    2,791

    Not true, depends if he has privileges or not.

    Not true, depends if he has privileges or not.
  17. Replies
    10
    Views
    2,791

    localadministrator is the user name to use but...

    localadministrator is the user name to use but unless you have the password that the dealer used during setup, your not going to get in. They used to have back door passwords for the older EBT...
  18. Replies
    12
    Views
    2,360

    Serial port. You have a job bu?

    Serial port. You have a job bu?
  19. Replies
    12
    Views
    2,360

    What you have is called a Microview or lanview....

    What you have is called a Microview or lanview. The cards you have are TUX's not TUC's. This is called an ibex system. Unless the rep that installed it left a backup copy, and you have ibex software...
  20. Replies
    3
    Views
    463

    Looking for a New Service Truck....

    I am in the controls industry and need help in deciding what new vehicle to get. Started out in a mini van, then moved to a pickup with boxes and ladder rack. So i need to carry spare parts,...
  21. Replies
    7
    Views
    639

    The chiller and cooling tower actually does the...

    The chiller and cooling tower actually does the work. That is the refrigeration cycle. By compressing refrigerant, and using condenser and evaporator bundles, water as the medium, cycling the water...
  22. If you do a device scan you can determine what...

    If you do a device scan you can determine what controllers you have on your site. You need to find the device instance and find it in the list. As far as the balance page, it depends on your local...
  23. There is a setpoint that can be adjusted called...

    There is a setpoint that can be adjusted called calibration factor that is displayed on a balance page. This is contingent on the controllers being gen 4 and how your site is setup.
  24. Replies
    23
    Views
    2,638

    This wouldn't happen to be Cambridge Major would...

    This wouldn't happen to be Cambridge Major would it?
  25. Replies
    46
    Views
    11,181

    If you want it to be "like new" you would need to...

    If you want it to be "like new" you would need to renumber the vlc to 9999 and send the blank.bd4 file to it.
Results 1 to 25 of 44