Search:

Type: Posts; User: Gross

Page 1 of 17 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    5
    Views
    659

    Excessive? Idk, that's a comfort question only...

    Excessive? Idk, that's a comfort question only you can answer. I can tell you the higher the indoor air temp the higher the discharge temp/pressure will be. Higher pressures=more strain.
    That being...
  2. Honeywell truease (believe it or not) Very easy...

    Honeywell truease (believe it or not)
    Very easy for a home owner to service, motorized damper to keep unnecessary bypass to a minimum, comes with easy to use digital humidistat
  3. Replies
    35
    Views
    3,929

    Prestige iaq, vision pro 8000, 6000,5000,3000,...

    Prestige iaq, vision pro 8000, 6000,5000,3000, t87
    We like honeywell :)
  4. How the heck do you get banned in 6 hours?!

    How the heck do you get banned in 6 hours?!
  5. Replies
    26
    Views
    2,118

    First thing I would do is call the HVAC company...

    First thing I would do is call the HVAC company (or the builder, what ever that builders protocol is) and give them opportunity to fix. Like I said, it could be a number of different things. Some are...
  6. Thread: Time to Replace?

    by Gross
    Replies
    4
    Views
    487

    The energystar.gov site says once your heat pump...

    The energystar.gov site says once your heat pump is over 10 years old, you should strongly consider replacement before repairing it. 1998 was a LONG time ago, almost 18 years. Think of it this way,...
  7. Replies
    26
    Views
    2,118

    Everything is covered under a new home...

    Everything is covered under a new home warranty(unless you break it). How well they address it really matters on how much they value not getting negative feedback. Who was the builder?
  8. Replies
    26
    Views
    2,118

    It could be oversizing, it could be over fired,...

    It could be oversizing, it could be over fired, it sure needs to be balanced. Where is the home located? Is the builder a major builder or just a local joe?
  9. Replies
    2
    Views
    388

    You should apply for pro membership and ask this...

    You should apply for pro membership and ask this in the appropriate forum. You'll have better luck.
  10. Thread: Odor from ducts

    by Gross
    Replies
    5
    Views
    556

    What kind of filter are you using and is the...

    What kind of filter are you using and is the smell constant? You mentioned there isn't flooding issues which makes me think u have a downflow furnace, is that correct?

    Burnt moisture doesn't make...
  11. Thread: Trane airflow

    by Gross
    Replies
    7
    Views
    906

    Awesome, thanks!

    Awesome, thanks!
  12. Thread: Trane airflow

    by Gross
    Replies
    7
    Views
    906

    Tam7 is an air handler....I need a furnace....

    Tam7 is an air handler....I need a furnace.
    Maybe I'm asking the question the wrong way if I have any trane variable speed furnace and I set the cooling airflow to 1600 CFM. What will my air flow be...
  13. Thread: Trane airflow

    by Gross
    Replies
    7
    Views
    906

    Avptc is a goodman airhandler.hence the improper...

    Avptc is a goodman airhandler.hence the improper af. I'm asking for model numbers here... I'm not getting rid of the xl19, simply the airhandler.... I need to know if ALL trane VS furnaces have the...
  14. Thread: Trane airflow

    by Gross
    Replies
    7
    Views
    906

    Trane airflow

    As a percentage of nominal, what is y1 airflow?
    I have a xl19 hooked up to a avptc ah and the latent removal has always sucked due to the 75%y1 af vs the low stage comp at 50%. I'm switch to Lp...
  15. Replies
    35
    Views
    3,512

    Almost agreed...even if it's under warranty...

    Almost agreed...even if it's under warranty (there are a few) you just get a g20
  16. Replies
    6
    Views
    681

    You would need hvac tools to do it. It's...

    You would need hvac tools to do it. It's something a technician shouldve measured in the diagnosis of a bad txv. 59 degrees MAY be a good temp, again, not enough info.
    If you can get a tech to give...
  17. Replies
    6
    Views
    681

    Well, I know you weren't asking for advice on...

    Well, I know you weren't asking for advice on pricing buttttt please be mindful of our policy on listing pricing in the future...
    Anywho, the answer to your question is a definite maybe. A filter...
  18. Thread: Trane XL14i

    by Gross
    Replies
    4
    Views
    581

    It's a sound blanket. It makes it quieter.

    It's a sound blanket. It makes it quieter.
  19. Replies
    12
    Views
    1,689

    They are against code in some localities

    They are against code in some localities
  20. Replies
    9
    Views
    1,086

    It also sounds like you're using the same...

    It also sounds like you're using the same velocity for supply and return ducts in your math. That's where you're messed up
  21. Replies
    9
    Views
    1,086

    It can't have a higher cfm than the supply....

    It can't have a higher cfm than the supply. Velocity is lower in order to have less noise and to compensate for filter restriction
  22. Replies
    6
    Views
    926

    What model indoor and outdoor and what is the...

    What model indoor and outdoor and what is the indoor temp when it's blowing cooler air and the outdoor temp when it's when your measuring the indoor temp?

    Heat pumps don't "create" heat by turning...
  23. Replies
    58
    Views
    8,802

    I would spit on someone if they gave offered me...

    I would spit on someone if they gave offered me 20/hr
  24. Thread: Safety Third

    by Gross
    Replies
    35
    Views
    6,507

    Way too much focus/caring about a trailer that...

    Way too much focus/caring about a trailer that sounds like everyone would be better off if it did burn to the ground.
  25. Systems are less efficient and will fail sooner...

    Systems are less efficient and will fail sooner when running on low stage constantly
  26. Tell him to check your subcooling. Banging may be...

    Tell him to check your subcooling. Banging may be an indication over over charging
  27. Replies
    6
    Views
    2,230

    The amana dgsx exists on computers and warranty...

    The amana dgsx exists on computers and warranty forms only. It is a goodman( hence the g) but you pay extra to call it an amana. All it really does is give you a better compressor warranty at 13 seer.
  28. Replies
    0
    Views
    1,047

    True steam question

    Since honeywell customer support is useless, here:
    I realized that the hm512w1005 is discontinued. How ever, it looks like the package was discontinued, but it's still the model number of the...
  29. Replies
    3
    Views
    2,073

    Did you want it?

    Did you want it?
  30. Replies
    3
    Views
    2,073

    Sure do

    Sure do
  31. Replies
    7
    Views
    1,498

    hm. i have elite and wrightsoft. i prefer...

    hm. i have elite and wrightsoft. i prefer wrightsoft. if they accept elite ill bet they take wrightsoft as well

    best advice? take the class on how to use it.
    too many little things to learn with...
  32. Thread: Megger?

    by Gross
    Replies
    10
    Views
    5,547

    i have a supco as well...m500 i think.. for...

    i have a supco as well...m500 i think..
    for residential, its the best.
    heres why: it literally says good or bad. involve the homeowner, have them push the button...they see if its good or bad for...
  33. Replies
    43
    Views
    19,179

    since youve set up so many nest...

    since youve set up so many nest thermostats...you'd know they dont work with dual fuel set ups with out an all fuel board.....

    so no, its not going to work.
  34. Replies
    3
    Views
    2,073

    TIF 8500A CO analyzer

    It's basically new. It was bought and used one time by the old manager and he left it behind...that was two years ago and its time to get out of my warehouse! Mechanically its complete, the only...
  35. Replies
    43
    Views
    19,179

    ecobee's are really neat. expensive as all get...

    ecobee's are really neat. expensive as all get out, but neat. still would take the infinity
  36. Replies
    43
    Views
    19,179

    its still a downgrade

    its still a downgrade
  37. Replies
    43
    Views
    19,179

    http://lmgtfy.com/?q=nest+compatibility

    http://lmgtfy.com/?q=nest+compatibility
  38. Replies
    43
    Views
    19,179

    it is a downgrade. ive installed them...they...

    it is a downgrade.
    ive installed them...they are cool, but no where near as functional or as capable as the infinity control. get teh wifi infinity control if you want the iphone app.
  39. Brand, in my opinion( and consumer reports) has...

    Brand, in my opinion( and consumer reports) has almost nothing to do with quality. Picking a qualified and thorough contractor is what matters the most
  40. Replies
    38
    Views
    5,643

    I've had a York package unit blow the glass outta...

    I've had a York package unit blow the glass outta the compressor in Afghanistan bc the filter drier was on the discharge line and it was completely blocked... 165 degree odt and condenser coils dont...
  41. Replies
    29
    Views
    6,683

    In response to " attend a class" do you know Jim...

    In response to " attend a class" do you know Jim Davis teaches THE class??
  42. Replies
    6
    Views
    1,553

    309961 this is it most of the way done

    309961

    this is it most of the way done
  43. Replies
    6
    Views
    1,553

    i had the same issue....what i did was put 2...

    i had the same issue....what i did was put 2 20x25 4" in...now i have a .07" drop!
  44. Thread: Magic Pak!

    by Gross
    Replies
    6
    Views
    1,389

    piercing valves make your life much easier!...

    piercing valves make your life much easier!
    http://www.hvacr-tools.com/product/c-d-valve-cd4311-fastap-tube-piercing-pliers
  45. Replies
    39
    Views
    10,872

    Sounds like a cop out answer, BUT I'm glad your...

    Sounds like a cop out answer, BUT I'm glad your issue has Bren resolved!
  46. Replies
    1
    Views
    688

    If what you have described is accurate, then you...

    If what you have described is accurate, then you most likely dont have a properly ventilated attic...BUT dont worry! most people dont!
    if you dont have humidity issues, a great way to keep that heat...
  47. Replies
    19
    Views
    2,601

    #1: could be normal. sounds like yours is either...

    #1: could be normal. sounds like yours is either sweating too much OR hers is not sweating enough. that could be a charge issue, air flow issue, or even a sizing issue

    #2 it can be adjusted......
  48. Thread: DOA scroll

    by Gross
    Replies
    3
    Views
    884

    The static was .63, I measured actual airflow ...

    The static was .63, I measured actual airflow

    It was 410a. It was about 145 low and 345 hi
  49. Replies
    23
    Views
    4,466

    www.certaincomfort.org you can find certified...

    www.certaincomfort.org

    you can find certified air balancers there who will solve your problems
  50. Thread: DOA scroll

    by Gross
    Replies
    3
    Views
    884

    DOA scroll

    im wanting to know what, specifically, is going on inside this compressor...if anyone has cut one open because of this, it would be great!

    brand new 3 ton hp would not cool... i had 13 degrees sc...