  1. Replies
    6
    Views
    231

    It looks like you are trying to add a network...

    It looks like you are trying to add a network point from spyder tool into niagara point folder. You would have to add the point to the spyder control program and then proxy it into niagara
  2. Replies
    6
    Views
    231

    Try using a custom enumeration instead of a val...

    Try using a custom enumeration instead of a val ubyte point.
  3. Replies
    6
    Views
    231

    In the advanced tab of the software point in the...

    In the advanced tab of the software point in the Spyder select MSV instead of AV
  4. Replies
    20
    Views
    660

    Just get a Lon Spyder and make your life simpler

    Just get a Lon Spyder and make your life simpler
  5. Replies
    4
    Views
    168

    Sorry, if your points were going stale your unit...

    Sorry, if your points were going stale your unit should default to its preset setpoints in the unit which should prevent your freeze up issue.
  6. Replies
    4
    Views
    168

    It sounds like you have stale points, meaning the...

    It sounds like you have stale points, meaning the data is not updating on your front end. What type of front end do you use to access your equipment?
  7. If you are writing to the nviDACLSP (LON) it will...

    If you are writing to the nviDACLSP (LON) it will override other setpoint. Unsure about bacnet but would assume the same.
  8. Replies
    25
    Views
    1,524

    Are the Java settings the same in each PC? I have...

    Are the Java settings the same in each PC? I have found unchecking keep temp files on computer fixes browser issues.
  9. Replies
    2
    Views
    164

    Actually after playing around with the setpoints...

    Actually after playing around with the setpoints I found that changing the nciOccHeatSetpoint changes both the Occ Heat and the Morning Warmup setpoint in the RTU, updates on the HI to reflect...
  10. Replies
    2
    Views
    164

    Trane IntelliPak MWU question

    Been a while since I've dealt with these units. I was under the impression that the morning warmup used the occupied heating setpoint as its termination setpoint but the warmup seems to shut down...
  11. Thread: Vehicles

    by mechmike2
    Replies
    0
    Views
    177

    Vehicles

    Boss is looking to get new trucks and is looking into Nissan mini cargo vans. i have heard that you can't fit a 6' ladder in 1 of these. Anyone have one? What do you think?
  12. Thread: Trucks

    by mechmike2
    Replies
    23
    Views
    917

    Trucks

    Boss is looking to get new trucks and is looking into Nissan mini cargo vans. i have heard that you can't fit a 6' ladder in 1 of these. Anyone have one? What do you think?
  13. Replies
    7
    Views
    389

    It is recommended that you change the default...

    It is recommended that you change the default user name and password when you commission a Jace. It makes it a pain in the a.ss but it is recommended. There are programs out there that can search for...
  14. Drop 15cforLearn device on lon bus, rename as...

    Drop 15cforLearn device on lon bus, rename as needed. Match up field device to the XL15cfor Learn device. In actions do a learn then upload. You can then view wiresheet of I/O, Flex and Logic...
  15. Check your email

    Check your email
  16. Thread: Carrier vvt

    by mechmike2
    Replies
    4
    Views
    373

    Check out one of these zoning stats Honeywell...

    Check out one of these zoning stats Honeywell TB6980B1006/U. Have used them in the past. Would install discharge sensor and the stat would simply open damper if space needed cooling and supply air is...
  17. Replies
    16
    Views
    629

    If you are licensed the honeywell AX Wizard...

    If you are licensed the honeywell AX Wizard module makes it simple. If you not licensed the lonHoneywell module is there but not as easy.
  18. Replies
    1
    Views
    307

    York Literature

    Trying, in vain, to find literature for a York RTU M# Y13AN4413OABBCC. Google gives me nothing, Johnson nothing. Looking for IOM / Wiring Diagrams.
  19. Replies
    4
    Views
    264

    Add your email to your profile and I can send you...

    Add your email to your profile and I can send you some info
  20. Replies
    1
    Views
    217

    Spyder upgrade issue

    Just thought I give Spyder users a heads up on issue when upgrading sites from older Spyder tool (4.8.8) to newer (5.210). Your Compare blocks loose their Greater, Less, Equal slot and if controller...
  21. Replies
    12
    Views
    717

    Blocks you should need can be found in the math...

    Blocks you should need can be found in the math folder of the kitcontrol module.
  22. Replies
    2
    Views
    339

    Honeywell Buildings Forum

    Anyone else having log-in problems with site?
  23. Replies
    10
    Views
    637

    If you have a battery in your jace it does the...

    If you have a battery in your jace it does the same thing. I believe that is the only reason for a battery, to back up the site in the event of a power failure. But now you have to buy the battery...
  24. Replies
    3
    Views
    234

    If you go on the wiresheet of the IO's put cursor...

    If you go on the wiresheet of the IO's put cursor over input that is feeding the analog output and it will tell you what is sending the signal to the output. You can then find the status nvo from the...
  25. Replies
    10
    Views
    637

    I am curious what the benefit of using the Data...

    I am curious what the benefit of using the Data Recovery Service is other than not needing a battery?