  1. Thread: Goodman Problem

    by topdog
    Replies
    23
    Views
    1,959

    Yes the furnace will shut down if condensate...

    Yes the furnace will shut down if condensate water does not flow.
    You should see water in the open trap(gray box), if not , prime the trap with water and see if it is draining.
  2. Thread: Goodman Problem

    by topdog
    Replies
    23
    Views
    1,959

    High eff. furnace means it is a condensing...

    High eff. furnace means it is a condensing furnace? Induced draft? Sealed burner? System shuts off after one hour run and temperature not reached?

    Suggest check amps on blower motor or induced...
  3. Thread: Goodman Problem

    by topdog
    Replies
    23
    Views
    1,959

    Where is the furnace located? Is it a 80% or...

    Where is the furnace located? Is it a 80% or 90%? Has there been any new work doneto the house?
  4. Replies
    5
    Views
    556

    On the east coast, temperature went from below...

    On the east coast, temperature went from below normal to above normal[feast or famine as we say], company that I work with took on warranty companies -too many- boss wants cash flow, end of story. ...
  5. Replies
    10
    Views
    9,108

    I believe he meant themidistat,which not only...

    I believe he meant themidistat,which not only controls humidity into a dry house but also removes humidity when the house is damp. True most contractors won't install a humidifier in an attic or any...
  6. Replies
    89
    Views
    7,039

    I am an Amerasian and never used my minority...

    I am an Amerasian and never used my minority status for job placement or benefits. I am an American U.S. citizen and want to earn my wages and respect as such. The most important person on any job...
  7. Replies
    10
    Views
    9,108

    Sorry to here about the bad luck with the 14 year...

    Sorry to here about the bad luck with the 14 year old system. I work the DC and Baltimore area and based in Annapolis, MD. Heatpump systems in our area with annual maintenance, usually last 16-20...
  8. Replies
    17
    Views
    1,562

    If designed properly electro-mechanical zoning...

    If designed properly electro-mechanical zoning systems are excellent and can even reduce the tonnage and electricity needed to perform adequate heating and cooling. It is not cheap to install...
  9. Replies
    12
    Views
    3,927

    Need to know tonnage of eqiuipment and duct sizes...

    Need to know tonnage of eqiuipment and duct sizes to make proper adjustments. 8" Flex = 150cfm at .10 static. If it is a return....... less cfm
  10. Replies
    10
    Views
    956

    Been using Carrier Comfort Zone system for over...

    Been using Carrier Comfort Zone system for over 10 years, commercial and residential and works great. Hope you said variable speed outdoor system and not indoor unit. Don't believe you can zone with...
  11. Replies
    10
    Views
    9,108

    What happen to the old system?...

    What happen to the old system? Age,burn-out,improper sizing....etc? With the new 13 seer systems make sure duct sizing and load calculations are within specifications, thus you don't repeat...
  12. Thread: Lennox HP

    by topdog
    Replies
    3
    Views
    737

    Lennox heatpump model # HP19-461-6P what is the...

    Lennox heatpump model # HP19-461-6P what is the tonnage?

    TIA, TD
  13. Replies
    14
    Views
    1,009

    No your not asking too much from a distributor....

    No your not asking too much from a distributor. You gave them plenty of time to get your order together and get what parts were necessary. At least to call you back to say if something was not...
  14. Replies
    4
    Views
    575

    If you're putting in variable speed system would...

    If you're putting in variable speed system would not suggest putting dampers in lines to balance air flow or may have motor failure.
  15. Thread: duct work

    by topdog
    Replies
    15
    Views
    1,525

    chillbilly this on the return side, I would...

    chillbilly this on the return side, I would suggest going to .08 to check cfm capabilities.
  16. Thread: duct work

    by topdog
    Replies
    15
    Views
    1,525

    I agree with trane. Flex duct is not the same cfm...

    I agree with trane. Flex duct is not the same cfm as round hard pipe and the pleated filter does restrict airflow even more. You're vs motor doesn't know whether to #@%& or get off the pot.
  17. Thread: Hey Norm...

    by topdog
    Replies
    1
    Views
    529

    OOPS thought I was in General Discussion for a...

    OOPS thought I was in General Discussion for a "Cheers" revival.
  18. Thread: wasted trips

    by topdog
    Replies
    25
    Views
    2,056

    Yeah,but your light stayed on and the batteries...

    Yeah,but your light stayed on and the batteries are dead.
  19. Replies
    18
    Views
    1,625

    bullshoot, you're new to trade stick around and...

    bullshoot, you're new to trade stick around and you'll develop the tough skin you're going to need to continue in this trade. Judging from the replies, I don't think some of these guys knew that...
  20. Replies
    18
    Views
    1,625

    Trying to check in heating at that ambient is...

    Trying to check in heating at that ambient is going to be tough. If I remembered correctly Trane doesn't even have a chart for that. You're in a deadzone. But I could be mistaken,maybe someone has a...
  21. Thread: duct work

    by topdog
    Replies
    15
    Views
    1,525

    If it were hard pipe 10 would be around 350cfm...

    If it were hard pipe 10 would be around 350cfm and 12 600cfm. Flex duct is less. How much less, maybe someone else will reply. 10x20=550cfm 20x16=900cfm
  22. Replies
    9
    Views
    1,080

    Look at this thread ...

    Look at this thread http://hvac-talk.com/vbb/showthread.php?threadid=38790
  23. Thread: wasted trips

    by topdog
    Replies
    25
    Views
    2,056

    Flashlight

    Flashlight
  24. Replies
    9
    Views
    1,080

    A 13 seer unit made by one manufacturer or...

    A 13 seer unit made by one manufacturer or another is still only capable of doing 13 seer when matched properly. It's the install that makes the system last longer.

    I would check to see how many...
  25. Replies
    6
    Views
    1,079

    It's kinda like holding a universal CFC licence,...

    It's kinda like holding a universal CFC licence, huh doc?