Search:

Type: Posts; User: superfittertech

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    13
    Views
    363

    Pro1IAQ stat made in china with 1 year warranty....

    Pro1IAQ stat made in china with 1 year warranty. Even if powered by the HVAC equipment must also install batteries or on a power failure or shutting power off the unit to service the stat looses time...
  2. Replies
    22
    Views
    923

    We inspect quarterly and usually only have to...

    We inspect quarterly and usually only have to remove a link or 2 annually when you are busy replacing the belts. They also create a lot less wear on the pulleys compared to regular belts. not...
  3. Replies
    21
    Views
    3,422

    300 psi couplings or as we call them extra heavy...

    300 psi couplings or as we call them extra heavy couplings. If you notice besides tapered threads that they're about 1/2"- 3/4" longer and a better quality type of steel than a merchant coupling. We...
  4. Replies
    5
    Views
    320

    Put the flex line into a 5 gallon bucket (not all...

    Put the flex line into a 5 gallon bucket (not all the way to the bottom) or put a loop in the flex. This way it will act like a "p" trap. Cold air will only come into space when the water heater is...
  5. Replies
    42
    Views
    1,091

    sticking with R-22 until no longer available

    sticking with R-22 until no longer available
  6. Replies
    2
    Views
    228

    sounds like either loose pulley of belt going bad

    sounds like either loose pulley of belt going bad
  7. Replies
    22
    Views
    923

    you guys are either incompetent or just plain...

    you guys are either incompetent or just plain wrong. They are excellent on Power roof ventilators especially for kitchen exhaust. Yes they stretch, but much less than a regular belt and they slip...
  8. Replies
    7
    Views
    377

    I only carry power twist link belts

    I only carry power twist link belts
  9. Replies
    4
    Views
    288

    because there would be a lot more DIY'RS...

    because there would be a lot more DIY'RS installing them improperly
  10. Replies
    25
    Views
    819

    Maybe from where you're from thats the case, but...

    Maybe from where you're from thats the case, but here they run heat anytime OSA is below 50 degrees which is about 9 months a year.

    The nice thing about direct fired MUA'S is they modulate down to...
  11. Replies
    5
    Views
    261

    they won't. Way too much pressure

    they won't. Way too much pressure
  12. braze only

    braze only
  13. Replies
    51
    Views
    2,370

    No they're an aluminum alloy

    No they're an aluminum alloy
  14. Replies
    45
    Views
    2,921

    I would have used a Spirovent instead

    I would have used a Spirovent instead
  15. Replies
    25
    Views
    962

    As long as you pipe in a pipe union. Most quality...

    As long as you pipe in a pipe union. Most quality installers do
  16. Replies
    25
    Views
    962

    Bradford White made in Michigan

    Bradford White made in Michigan
  17. Replies
    51
    Views
    2,370

    I bought ratcheting tubing bender. Replaced my...

    I bought ratcheting tubing bender. Replaced my Yellow Jacket. I actually like it better
  18. Replies
    30
    Views
    1,143

    unless you know to do alignments then I would...

    unless you know to do alignments then I would pass. If you don't get it correct it'll take out your shaft seal shortly. I've worked on thousands and rebuilt hundreds. If you're handy, work in house...
  19. Replies
    15
    Views
    590

    If can't run 2 separate PVC vent pipes another...

    If can't run 2 separate PVC vent pipes another option would be a condensing boiler, indirect water heater, and an air handler with a hot water coil and DX if you have A/C
  20. Replies
    15
    Views
    590

    you must have a natural draft water heater...

    you must have a natural draft water heater presently. Could always run PVC from power vent up chimney or could run both in chimney
  21. Honeywell Vision Pro with an EIM and a gateway

    Honeywell Vision Pro with an EIM and a gateway
  22. hire hot looking secretaries and dispatchers

    hire hot looking secretaries and dispatchers
  23. Replies
    24
    Views
    1,240

    you want some cheese with your wine

    you want some cheese with your wine
  24. you are definitely very wrong. The colder the air...

    you are definitely very wrong. The colder the air the higher the oxygen content the better the burn. A furnace doesn't loose efficiency because of cold air
  25. terminal on upper right with larger white wire is...

    terminal on upper right with larger white wire is the "g" terminal. that is the common on Modines