Search:

Type: Posts; User: bnick99301

Search: Search took 0.00 seconds.

  1. Replies
    33
    Views
    4,133

    I agree with what the guys said before. In my...

    I agree with what the guys said before. In my opinion you always want to bring your system down to 500 microns..blank it off and let it sit. So many guys I know in this trade pull it to 500 and say...
  2. Replies
    40
    Views
    4,767

    not gonna lie I installed a pump down valve...

    not gonna lie I installed a pump down valve backwards once....we all know what that would cause...:whistle:.......needless to say that got fixed...
  3. Replies
    7
    Views
    733

    valve spring would be my guess. Or pull the fan...

    valve spring would be my guess. Or pull the fan lead and bump the head pressure see if it maybe blows through or u get that ringing sound to come out.
  4. Replies
    18
    Views
    1,364

    If the system is as old as what you are implying...

    If the system is as old as what you are implying and your friend doesn't want to spend the money for the board and you assume its the *relay* just wire the motor to strait power. Let it run all the...
  5. Replies
    6
    Views
    689

    I'm confused with a few things in your post. One...

    I'm confused with a few things in your post. One being (hydro Bill) >? The RLA wont change in heating model. My guess with the limited amount of info is that you might be a little big under charged...
  6. Replies
    13
    Views
    2,009

    For the Future

    What I have learned in the past is, if you didn't diagnose the problem and your going back to fix it. It never hurts to check the system out for yourself to see what its doing. Time and time again...
  7. Replies
    15
    Views
    2,300

    Subcooling used for TXV Superheat on Cap tube

    Subcooling used for TXV
    Superheat on Cap tube