  1. You need the ax wizards module in order to upload...

    You need the ax wizards module in order to upload the programming and see the points. You cant generate an xml with those.

    Sent from my SCH-R530U using Tapatalk
  2. Replies
    8
    Views
    983

    Can you send me the contact also. My email is in...

    Can you send me the contact also. My email is in my profile. Thanks.:bump:
  3. Replies
    4
    Views
    484

    You will have to put the jcin2.jar and other...

    You will have to put the jcin2.jar and other modules in your install folder so your workbench can see whats in the N2 network.
  4. Replies
    14
    Views
    1,251

    You can still use the Jace in the same way by...

    You can still use the Jace in the same way by leaving "Routing" on in your Bacnet Network setup. Then it will route all bacnet communications just like a router would. Best of all, I don't think...
  5. Replies
    6
    Views
    753

    If what you want could be done, I think a Bql...

    If what you want could be done, I think a Bql query would be the way. But I don't know if you can use bformat text that way. I am sort of trying to do the same thing.

    Anyone else have any ideas?
  6. Replies
    14
    Views
    1,251

    I have done this before, but Bacnet IP is alot...

    I have done this before, but Bacnet IP is alot easier with the NAE's. I just used a Contemporary Controls Bacnet router to serve the points. Far less expensive than a Jace.
  7. Replies
    5
    Views
    913

    Normally I start with a TR of three to five times...

    Normally I start with a TR of three to five times my setpoint and an integral of about 60 seconds. So if your setpoint is 1" I would start with a TR of 3-5.
  8. Replies
    18
    Views
    2,893

    I have seen this before, they probably want...

    I have seen this before, they probably want demand based ventilation with indoor ppm compared to outdoor ppm. When indoor ppm is say 700 above outdoor ppm then start increasing intake air volume. ...
  9. Replies
    11
    Views
    1,507

    Has anyone ever successfully had a Lynxspring...

    Has anyone ever successfully had a Lynxspring relicensed to be open?
  10. Replies
    2
    Views
    385

    The last line says it all, try loading a known...

    The last line says it all, try loading a known good station and see if it works. If it does, than the first one is junk. If it doesnt work, try reloading the os.
  11. Replies
    5
    Views
    553

    Wow, I didn't realize the gateway was such a...

    Wow, I didn't realize the gateway was such a loser. I guess I'm not surprized though.
  12. Replies
    5
    Views
    553

    I believe Wattmaster has some sort of Bacnet...

    I believe Wattmaster has some sort of Bacnet gateway available. I would look into that but it may be less expensive to replace the controls instead.
  13. Replies
    25
    Views
    2,028

    I was one of the beta testers for these displays....

    I was one of the beta testers for these displays. Our display shorted itself as soon a power was hooked up, so testing for us was short. As a result I wouldn't be able to tell you how well they...
  14. Replies
    12
    Views
    1,999

    This forum isn't for giving directions, if you...

    This forum isn't for giving directions, if you have a more specific problem or question you need help with we would be glad to help.
  15. Replies
    12
    Views
    4,652

    Me too Mike. Thanks!

    Me too Mike. Thanks!
  16. Replies
    13
    Views
    2,645

    If your going to use bacnet/ip, I wouldn't bother...

    If your going to use bacnet/ip, I wouldn't bother with an FX-60. Use another brand like Vykon with less crap loaded on it.
  17. Replies
    31
    Views
    2,274

    Spyders are not supported on 201's, not enough...

    Spyders are not supported on 201's, not enough horsepower.
  18. Thread: LON over IP

    by ddcfreek
    Replies
    24
    Views
    2,429

    There is only one lon channel and only one 600.

    There is only one lon channel and only one 600.
  19. Replies
    26
    Views
    4,054

    Look at Contemporary Controls P/N BASRTP-B or the...

    Look at Contemporary Controls P/N BASRTP-B or the JCI equal. It is a mstp to ip router for bacnet.
  20. Thread: LON over IP

    by ddcfreek
    Replies
    24
    Views
    2,429

    The ultimate goal is the remove the iLon from...

    The ultimate goal is the remove the iLon from EBI. The entire facility is going from EBI and migrating to AX. For now I have both EBI and AX in the config server so I don't interupt comm.
  21. Thread: LON over IP

    by ddcfreek
    Replies
    24
    Views
    2,429

    lwarren: Did you discover the Ilon's or did you...

    lwarren:
    Did you discover the Ilon's or did you have to add them manually? Were you able to discover points?

    The config server is in the EBI computer and I already added my jace.

    The rest:...
  22. Thread: LON over IP

    by ddcfreek
    Replies
    24
    Views
    2,429

    The 600 is already passing data to EBI, I was...

    The 600 is already passing data to EBI, I was simply hoping I could add AX in the network and discover.

    It may come to that, I just hate to waste usefull hardware.

    That seems harder than just...
  23. Replies
    3
    Views
    474

    GE documentation on the Prosys 2 system doesn't...

    GE documentation on the Prosys 2 system doesn't mention LON at all except that you need to upgrade to Prosys LM to get it. Which is why I am confused that there is LON repeaters being used.
  24. Thread: LON over IP

    by ddcfreek
    Replies
    24
    Views
    2,429

    600 I think.

    600 I think.
  25. Thread: LON over IP

    by ddcfreek
    Replies
    24
    Views
    2,429

    It is licensed for IP, do they get licensed for a...

    It is licensed for IP, do they get licensed for a certain number of clients? Right now it is using IP to Honeywell EBI and I am trying to stick my computer in with AX software to see if it works. ...