    NAE to JACE-JCI bac-net contollers

    I am working on an integration from NAE to AX JACE 600 that has JCI bac net controllers as the field devices, and am running into some strange issues. For example, the controllers will call for heat,...
  2. Replies
    7
    Views
    675

    cool, thanks alot. do you happen to know what...

    cool, thanks alot. do you happen to know what documents actually explain that, I cant find it anywhere...
  3. Replies
    7
    Views
    675

    thanks for the input froz, but how does the temp...

    thanks for the input froz, but how does the temp offset interfere with the sa-vp reading, not sure that I have encountered that.......
  4. Replies
    7
    Views
    675

    johnson VMA offsets

    hey,

    does anybody know why when you configure a new johnson VMA there is a default temp offset of -1.5, are their sensors setup to accept that offset and read correctly out of the box, or should...
  5. Replies
    5
    Views
    639

    thanks guys, this was basically a hypothetical...

    thanks guys, this was basically a hypothetical question,what auto pilot said was basically what I was getting at, if the pressure from each pump is evenly displaced, then you would think that where...
  6. Replies
    5
    Views
    639

    running two pumps

    If you have two pumps in a condenser water loop, and one pump (they are identical) is operating at say 50 amps, while the other is at say 40 amps, (They are both receiving a command of 100%) does...
  7. Replies
    16
    Views
    1,667

    Thanks nyrb, that was exactly what I needed!! I...

    Thanks nyrb, that was exactly what I needed!! I appreciate you taking the time to really explain it, and thank you to the other posters as well. cant wait to share with everybody at work, I have a...
  8. Replies
    16
    Views
    1,667

    well, I guess im thinking of a situation where...

    well, I guess im thinking of a situation where you have a vdc output on a controller and a end device that wants to see a ma signal, and you need to fix it asap. and when you say the extent of your...
  9. Replies
    16
    Views
    1,667

    thanks alot , havent had a chance to to go to the...

    thanks alot , havent had a chance to to go to the links yet, but im sure that will clear up some questions. Its amazing to me how many people say that it works both ways, how can so many people be...
  10. Replies
    16
    Views
    1,667

    using resistors to change signal type

    I was wondering if anyone would mind taking the time to explain using resistors to change signal types. Im a little confused as to which way they can be used, i.e they can change ma signal to vdc...
  11. Replies
    10
    Views
    1,661

    makes sense! thanks alot

    makes sense! thanks alot
  12. Replies
    10
    Views
    1,661

    thanks alot guys, it seems that changing the set...

    thanks alot guys, it seems that changing the set point as opposed to the AI actually does work faster......weird
  13. Replies
    10
    Views
    1,661

    johnson VMA box heating

    Hey guys,

    I had to commission some PIUs today, johnson controls VMA controllers. Im kind of new to them (and control's in general I guess..2 yrs). when I override the fan or heat on they come on...