Search:

Type: Posts; User: Apprenticanic

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    22
    Views
    1,540

    Any calls back to this 'black hole' or has all...

    Any calls back to this 'black hole' or has all been fixed after replacing the oil level regulator? It's been a few weeks now so it's passed the '1 week' test of the old tech who quit on it :grin2:
  2. Replies
    34
    Views
    2,954

    Ah, didn't think of the multi evap pump down...

    Ah, didn't think of the multi evap pump down scenario, good call. - Also, good call on realizing this is a thread that has risen from the dead, didn't notice the dates, hah.
  3. Replies
    34
    Views
    2,954

    Didn't read all the responses so may be...

    Didn't read all the responses so may be repeating, but the receiver is only necessary for a system with a varying ambient temp surrounding the condenser. IE, outdoor condensing unit. Receiver used to...
  4. Replies
    31
    Views
    1,376

    At one time I definitely could relate to where...

    At one time I definitely could relate to where you are coming from. Same position, small company, take care of a large variety of different equipment and a lot of pressure to run around and put out...
  5. 583501583511583521 Gotta love being Canadian,...

    583501583511583521

    Gotta love being Canadian, eh? Shovels & hockey sticks are basically extremities to us :cheers:
  6. Replies
    33
    Views
    1,130

    Scott knows his stuff, I think he just goofed up...

    Scott knows his stuff, I think he just goofed up saying low SH means too much vapour in evap when he meant too much liquid, as the rest of his details were correct and correlated with that line of...
  7. Replies
    2
    Views
    260

    I just replied to your other post before seeing...

    I just replied to your other post before seeing this one, so I have answered some of my questions already. But, I never heard of PAT Institute. What do they offer as a pre-apprenticeship? Just gas or...
  8. Replies
    2
    Views
    269

    There's a good amount of work out here typically,...

    There's a good amount of work out here typically, on the Commerical/Industrial side at least. Right at the moment, most are a bit slow due to it being mid-season. If the company has a good...
  9. Replies
    37
    Views
    1,646

    Can't find any literature matching this model...

    Can't find any literature matching this model number. Closest I can find is a 50TC28 for an elect heat/no heat 25 ton unit. Trying to see what you're working with over there to try and help...
  10. The only hidden problems being with replacing...

    The only hidden problems being with replacing Carrier heat ex's are not ordering those 3 other parts that are almost always needed with it because they are so rusted out. Can turn your easy job into...
  11. It's a bit different up here in toronto, polar...

    It's a bit different up here in toronto, polar vortex last year crushed us. Was good for business though. I don't know of an exact definition of 'low ambient' but i would look at it this way,...
  12. You have a receiver on the unit so it can operate...

    You have a receiver on the unit so it can operate in low ambient, so your charge is based on the coldest expected ambient temperature for where the unit is located. It's called a flooded charge. A...
  13. Replies
    74
    Views
    4,551

    Let's hear it, PHM! .. Your stories are always a...

    Let's hear it, PHM! .. Your stories are always a great read.
  14. Replies
    60
    Views
    3,198

    Video explains a lot. There's always something...

    Video explains a lot. There's always something left out, huh? .. Take those measurements with the door on, you're bypassing the cond coil when it's off.
  15. Didn't see that one coming from all this,...

    Didn't see that one coming from all this, especially this far into the thread. Interesting curveball, Eddy.

    For future reference though, add ALL details/readings/measurements etc. you have into...
  16. Replies
    18
    Views
    1,363

    Any chance the relay is upside down? Just read...

    Any chance the relay is upside down? Just read that same issue in a different post which was caused by that
  17. Replies
    135
    Views
    6,044

    http://books.google.ca/books?id=hfsVmsYmuM0C&pg=PA...

    http://books.google.ca/books?id=hfsVmsYmuM0C&pg=PA263&lpg=PA263&dq=current+relay+mounting+upside+down&source=bl&ots=2QEbtoCgA0&sig=78uyjzAx8rgJiivAPqqex7G3bww&hl=en&sa=X&ei=yXkGVOC7BYefggT9ooLIAw&ved=...
  18. Replies
    16
    Views
    1,474

    I believe you are correct about the 'Spark...

    I believe you are correct about the 'Spark Killer' terminology TB, as that diagram is out of a Samsung ductless split. Pacific rim, indeed.
  19. Replies
    16
    Views
    1,474

    Thought that pic had more detail to the 'Spark...

    Thought that pic had more detail to the 'Spark Killer' but I think that's what you're talking about.... :

    spark-kil-ler

    [spahrk-kil-er] SpellSyllables

    Word Origin

    noun, Electricity
    1.
  20. Replies
    8
    Views
    682

    Sorry, just realized it was in the Pro section...

    Sorry, just realized it was in the Pro section and you're a new member, or long time creeper as it seems. Try replacing the cracked elbow and adding a vibration absorber of some sort.
  21. Replies
    8
    Views
    682

    Not sure about that method of silflossin' the...

    Not sure about that method of silflossin' the whole elbow but check out this thread, there's some good methods and options you can try to prevent it from reoccuring.
    ...
  22. Replies
    9
    Views
    1,157

    x2 . . . that's a strange way to sell yourself to...

    x2 . . . that's a strange way to sell yourself to get a job.
  23. Replies
    12
    Views
    888

    Yeah, my first thing i'd check is the head...

    Yeah, my first thing i'd check is the head pressure when it pumps down. Make sure it's not overcharged from the winter and stacking and tripping it. If it doesnt raise the head when you pump it down,...
  24. Replies
    65
    Views
    3,015

    Squirrel cage is also known as a forward curve...

    Squirrel cage is also known as a forward curve fan, and that tells you which way it should rotate. With the curves moving forward, scooping and pushing the air. There's also backward incline fans...
  25. Replies
    65
    Views
    3,015

    CCW from the shaft end and pulls air through that...

    CCW from the shaft end and pulls air through that dirty coil. :cool:
  26. Replies
    34
    Views
    2,436

    Not that hard, huh? With that superior knowledge...

    Not that hard, huh? With that superior knowledge I guess you're sippin' on some cold beer by now then. :cheers:
  27. Replies
    14
    Views
    1,262

    Absolutely! Ever-learning trade. Keeps you on...

    Absolutely! Ever-learning trade. Keeps you on your toes and keeps things interesting. Wouldn't have it any other way.
  28. Replies
    34
    Views
    2,436

    Hahaa me too, it's hilarious.

    Hahaa me too, it's hilarious.
  29. Replies
    32
    Views
    4,613

    My company lets me bank hours but it's after the...

    My company lets me bank hours but it's after the OT is worked in. Whatever my hours were for the week, including the accumulated OT hours, whatever it equals out to I get the option to bank however...
  30. Replies
    35
    Views
    1,913

    What's all this 480v, 277v, 180v all about...

    What's all this 480v, 277v, 180v all about anyways?? None of that up here. We see 575v, 347v per leg to ground. Or the typical 240v, 208v and of course 115v single. But i've wondered why do you guys...
  31. Replies
    14
    Views
    1,262

    I'd imagine you'd start getting some offers...

    I'd imagine you'd start getting some offers either soon for the cooling season as it's starting to get and stay hot around here now, or if you're still too far down the list, you may have to wait...
  32. Replies
    13
    Views
    1,394

    Didn't realize they could range so much in the...

    Didn't realize they could range so much in the tonnage, from 30 (or 25) ton down to 10 ton.
  33. Replies
    13
    Views
    1,394

    I believe he's got a system with 2 tandem...

    I believe he's got a system with 2 tandem compressors, one 10 ton and one 15 ton and apparently a 30 ton TEV, and is wondering how the large valve doesn't hunt when just one comp is running as it...
  34. Ah, the 'ol dick man pressed into the coil....

    Ah, the 'ol dick man pressed into the coil. Classic. Always gives you a laugh. I really like the 'LOL' after.
  35. Replies
    31
    Views
    3,051

    I'm thinking airflow.

    I'm thinking airflow.
  36. Replies
    18
    Views
    1,604

    I bet the unintentional humour would be quite...

    I bet the unintentional humour would be quite entertaining, for a bit at least. A week might be too much though, would likely lose all faith in humanity.
  37. Replies
    34
    Views
    2,436

    It undoubtably has an electrical short with that...

    It undoubtably has an electrical short with that dripping water, and most likely low on freezon.
  38. Replies
    32
    Views
    2,200

    Yeah, undoubtably if the ambient surrounding the...

    Yeah, undoubtably if the ambient surrounding the case you're trying to maintain 34*f is at 78*f, you're gonna have some humidity/frozen coil issues. I would be interested in hearing how it goes for...
  39. Replies
    19
    Views
    1,747

    Yikes! Glad to learn something new, but hope I...

    Yikes! Glad to learn something new, but hope I didn't make this very mistake just today. Replaced a core on the liquid side for a 410 system and just popped in the next one I had laying in my truck....
  40. Replies
    32
    Views
    2,200

    That doesn't sound unreasonable, i'm going to see...

    That doesn't sound unreasonable, i'm going to see how the 4 a day play out and hopefully it will suffice. It does get real hot n muggy around here pretty abruptly. Will reduce the defrosts once...
  41. Replies
    3
    Views
    743

    Wow, yeah good luck. I would take pecmsg's advice...

    Wow, yeah good luck. I would take pecmsg's advice and try to come up with a different location. That will be hell for the compressors
  42. Replies
    32
    Views
    2,200

    I looked through the book in the unit, said for...

    I looked through the book in the unit, said for air defrost recommended between 30-50 mins, but didn't say how many. I put it up the 4 a day for 40 mins and i'll see how that plays out. Set the A/C...
  43. Replies
    28
    Views
    3,884

    I'm having a bit of a difficult time...

    I'm having a bit of a difficult time understanding this. Does the head pressure go down if it's plugged due to no return gas to be compressed and therefore dropping the pressure leaving it sitting in...
  44. Replies
    3
    Views
    338

    What makes you think it is the board that is...

    What makes you think it is the board that is causing it to trip the breaker? It is tripping the low voltage breaker on the transformer? Sounds like there is probably a short to ground on the low...
  45. Replies
    32
    Views
    2,200

    Ok, thanks. These cases are definitely...

    Ok, thanks. These cases are definitely tempermental b*stards. I will try and dig up the manual or find it online and get some specs.
  46. Replies
    32
    Views
    2,200

    Yes, open display case 5 deck, 32' with 3 evaps...

    Yes, open display case 5 deck, 32' with 3 evaps off one cond unit. After digging in a bit further, I found 1 txv flooding one coil n frosting up much quicker than the others. The suctionline was...
  47. Replies
    32
    Views
    2,200

    Reach In Cooler Defrost

    What are y'all setting your defrost lengths/periods for defrost for reach in coolers, air defrost, no heaters. Time initiated/terminated. Having issue with a 32' case that froze up over the weekend....
  48. 20 hookers a year, still a @$$load of hookers....

    20 hookers a year, still a @$$load of hookers. (no pun intended)
  49. It threw me for a loop the first time I seen a...

    It threw me for a loop the first time I seen a Trane 50 ton split with tandem compressors, sight glass rivering with just one comp running but cleared up when the second kicked on. Not sure if...
  50. Replies
    13
    Views
    1,288

    Appreciate that, sir. Will do. I did take the old...

    Appreciate that, sir. Will do. I did take the old Prodigy board with me when I left, I didn't think to try and plug it all back in and see if there was even anything wrong with it in the first place,...
Results 1 to 50 of 432