Search:

Type: Posts; User: PPJ

Search: Search took 0.00 seconds.

  1. Replies
    9
    Views
    873

    2016 Obama's America.

    Saw this last night night and it really did explain many things that BHO has done. The real core 'values' that he lives by and is dragging our nation into.

    Worse is the next term, if that befalls...
  2. Replies
    13
    Views
    777

    13/13.. had to guess on Lincoln though.. guessed...

    13/13.. had to guess on Lincoln though.. guessed right
  3. Replies
    5
    Views
    1,928

    Results are in: My Contractor has provided a...

    Results are in:

    My Contractor has provided a University of Kentucky (ASHRAE sponsored) study that provided data that indicated that while a 100% bentonite fill is a comparative worst case...
  4. Replies
    5
    Views
    1,928

    Kevin, all of the drillings were dry, only the...

    Kevin, all of the drillings were dry, only the first well (left overnight) may have had some water in it after some time (they filled the first U-loop with water after installing and left it in the...
  5. Replies
    5
    Views
    1,928

    I'll reply to my own post... I ran some...

    I'll reply to my own post...

    I ran some numbers on Ground Loop Design software (the demo version, used the default heat load, can't be changed on demo).... only change was the grout thermal...
  6. Replies
    5
    Views
    1,928

    Vertical Closed Loop Grouting Issue

    Situation:
    Having a 5T, two speed, closed loop (vertical), DSH WF-Envision being installed(loop wells are in). Installer has grouted the wells (3x at 250', 5" bore, 16' spacing, reverse return)...
  7. Replies
    6
    Views
    1,996

    Kevin, thanks for the input... I think they...

    Kevin, thanks for the input...

    I think they are using methenol but I just heard from the 'planner' from the contractor, they are planning on re-using the excess 1" on other tasks... so we are...
  8. Replies
    6
    Views
    1,996

    Travis and the group, Thanks for the PM and...

    Travis and the group,
    Thanks for the PM and feedback...

    I will hear from the contractor in the morning... I should have clarified (to the forum) that this is a WF Envision 5T (water to air),...
  9. Replies
    6
    Views
    1,996

    5T Vertical, 1 hole at 250', U coils are 300'

    My contractor (SW Ohio) has drilled the first of 3 holes, hit solid limestone at 20' all the way to 250'. U loop coils were just delivered and are 300' vs. 250'.

    Should I have them drill the next...
Results 1 to 9 of 14
Comfortech Show Promo Image