Had one doing this last week. Harvest assist...
Had one doing this last week. Harvest assist solenoid was bad. It was not pushing the ice sheet off the evap during harvest. The ice sheet would not fall on its own and would give the max harvest...
-
11-05-2010, 09:00 PM
Thread: frymaster hot hi failure
by RuudInstaller- Replies
- 9
- Views
- 2,281
Drain switch only cuts power to gas valve on the...
Drain switch only cuts power to gas valve on the Frymaster fryers at McDonalds. The controller is powered by 12vac directly from the transformer in the back.
-
11-04-2010, 06:04 PM
Thread: frymaster hot hi failure
by RuudInstaller- Replies
- 9
- Views
- 2,281
I had this happen once at a McD's and after...
I had this happen once at a McD's and after changing everthing you did, I found it was the transformer giving inconsistent voltage which leads to erratic probe readings. each vat has its own...
-
08-26-2010, 06:41 PM
Thread: Manitowoc - Bad hot gas valve?
by RuudInstaller- Replies
- 18
- Views
- 1,891
This was good advice, except the harvest...
This was good advice, except the harvest pressures are absolutely important. Thats why the manuals bother to list acceptable harvest pressures, and they are used when using the diagnostic flowcharts...
-
08-13-2010, 06:18 PM
Thread: Pump down without receiver?
by RuudInstaller- Replies
- 14
- Views
- 1,104
If this unit is in a galvanized metal enclosure...
If this unit is in a galvanized metal enclosure it is very likely that the freezer was 502 and the cooler is 22. However anything is possible. All of the old ones that we work on for McD's are...
-
07-16-2010, 10:02 PM
Thread: My A/C Blew Up...
by RuudInstaller- Replies
- 14
- Views
- 2,056
All you need is one of those terminal repair...
All you need is one of those terminal repair kits, some spade terminals, a capacitor and youll be good :)
-
06-10-2010, 05:34 PM
Thread: Masterbilt W/I Freezer
by RuudInstaller- Replies
- 39
- Views
- 2,533
It looks like the evaporator is starving, could...
It looks like the evaporator is starving, could be low on freon, could be a bad EEV, could be a dirty condensor causing low capacity, could be a bad suction line thermistor giving bad superheat...
-
06-02-2010, 04:58 PM
- Replies
- 5
- Views
- 497
The ones I work on are usually in the airstream...
The ones I work on are usually in the airstream of the condensor discharge and are set at 55 or 60 degrees. Never seen a two speed condensor fan at a McDonalds, but there are many different store...
-
05-03-2010, 08:31 PM
- Replies
- 30
- Views
- 3,201
Hobart, yes. None of the others that I am aware...
Hobart, yes. None of the others that I am aware of.
-
05-03-2010, 08:06 PM
- Replies
- 30
- Views
- 3,201
Some of the ones we do still have A.D.A., John...
Some of the ones we do still have A.D.A., John Zink, and Sunbeam units too. Oh yeah and don't forget McCann's, Honeywell, White Rodgers, Penn Ventilator, and Greenheck
-
05-02-2010, 04:13 PM
- Replies
- 30
- Views
- 3,201
I work for a company that services about 100...
I work for a company that services about 100 McDonalds stores. There is a pretty steep curve learning to work on equipment in these stores. Everything is custom made only for Mcdonalds. To get...
-
04-28-2010, 09:26 PM
- Replies
- 3
- Views
- 488
Could be leaky harvest solenoid, could be bad...
Could be leaky harvest solenoid, could be bad TXV, could be tubes separating off back of evap, could be high head pressure causing loss of capacity. These are just a few possibilities. Good Luck
-
04-28-2010, 07:09 PM
Thread: Frymaster Computer Magic
by RuudInstaller- Replies
- 16
- Views
- 4,066
Or if they rip the wire off of the drain switch,...
Or if they rip the wire off of the drain switch, gas valve, or flame sensor while trying to open the drain valve, I have seen this many times.
-
04-28-2010, 07:04 PM
Thread: Manitowoc electrical puzzle
by RuudInstaller- Replies
- 13
- Views
- 730
Check for loose ground connections, the selector...
Check for loose ground connections, the selector switch is referenced to ground and so is the curtain switch, water probe, etc.. Loose ground=no lights on board. I have seen this once before. Machine...
-
04-19-2010, 06:17 PM
Thread: Icemaker brazing trouble
by RuudInstaller- Replies
- 9
- Views
- 815
Heat any receivers, accumulators and bottom of...
Heat any receivers, accumulators and bottom of compressor with system open to atmosphere to release the refrigerant that is held up in the oil in the system. This is most likely where the refrigerant...
-
04-09-2010, 08:12 PM
Thread: Ken's Beverage
by RuudInstaller- Replies
- 10
- Views
- 1,976
They are supposedly beverage experts, but none...
They are supposedly beverage experts, but none that I have met can successfully connect a soda system in any reasonable amount of time. I also do beverage systems and compete directly with Kens as we...
-
04-07-2010, 05:25 PM
Thread: Ongoing Argument At Work
by RuudInstaller- Replies
- 11
- Views
- 1,017
Just off hand with a t/p chart evap coil temp...
Just off hand with a t/p chart evap coil temp about 25 degrees low side should be around 60 high side depends on setting of water regulator valve, but should be adjusted to about 235-240. These of...
-
03-30-2010, 06:55 PM
Thread: NUVU Proofer
by RuudInstaller- Replies
- 6
- Views
- 1,292
Are there two heaters? If so maybe the water pan...
Are there two heaters? If so maybe the water pan heater is not working which results in not enough moisture. Good luck
-
03-23-2010, 05:05 PM
Thread: Remote..... Octopus???
by RuudInstaller- Replies
- 19
- Views
- 4,009
Scotsman doesn't want the precharged linesets...
Scotsman doesn't want the precharged linesets cut, however the coils are to be horizontal and are to be left between the suspended ceiling and the roof. I have found this to be a major pain in the...
-
03-22-2010, 05:52 PM
- Replies
- 14
- Views
- 2,126
I bet that circ pump works really well with that...
I bet that circ pump works really well with that st. 90 on it. :?
-
03-01-2010, 09:30 PM
Thread: What would you do if......
by RuudInstaller- Replies
- 29
- Views
- 1,718
Turn the t-stat up to 80 and wait for the defrost...
Turn the t-stat up to 80 and wait for the defrost which shouldn't be more than 4 hours away. Maybe pull off the X terminal if I have my 6way in my pocket. But come to think of it if I had my six way...
-
02-26-2010, 06:15 PM
Thread: Scotsman "eye issues"
by RuudInstaller- Replies
- 7
- Views
- 1,126
FYI you can recall the errors in the controller...
FYI you can recall the errors in the controller even if the store resets the controller before you get there. I can't recall the procedure but it is explained in the back of the Scotsman service...
-
02-18-2010, 06:27 PM
Thread: Can you help me?
by RuudInstaller- Replies
- 28
- Views
- 2,962
It's Brockway Mountain, I went to Tech for a few...
It's Brockway Mountain, I went to Tech for a few years and went up there several times.
-
02-08-2010, 04:56 PM
- Replies
- 5
- Views
- 1,567
This has been common practice, as in the...
This has been common practice, as in the rewiring/elimination of comp discharge sensor, for our company for a few years now. We work for about 75 McD stores and this "update" has always corrected the...
-
02-02-2010, 05:28 PM
Thread: scottsman CME1056
by RuudInstaller- Replies
- 18
- Views
- 1,340
I may be wrong but that machine fills the water...
I may be wrong but that machine fills the water trough twice during freeze cycle, and will only harvest after second batch of fill water is used up. Also I believe that a new controller needs to be...